Abstract
Attributes of the remote measurement of piezometric water pressure and water level with time domain reflectometry (TDR) techniques are investigated. The evaluation includes a two-wire system for unusually small riser tubes as well as parallel wire and air-filled or hollow coaxial cable for typical installations. Comparison of TDR cable and commercial pressure transducer technology shows coaxial cable TDR systems with distance crimps capable of equaling and exceeding the resolution of pressure transducers. Crimps provide permanent distance markers that allow the TDR system to be self-calibrating.
Issue Section:
Research Papers
References
1.
Dalton
, F. N.
, Herkelrath
, W. N.
, Rawlins
, D. S.
, and Rhodes
, J. D.
, 1984
, “Time-Domain Reflectometry: Simulations Measurement of Soil Water Content and Electrical Conductivity with Single Probe
,” Science
1095-9203, Vol. 224
, June, pp. 989
-990
.2.
Dowding
, C. H.
, Su
, M. B.
, and O'Connor
, K. M.
, 1989
, “Measurement of Rock Mass Deformation with Grouted Coaxial Antenna Cables
,” Rock Mechanics and Rock Engineering
0723-2632 https://doi.org/10.1007/BF01274117, Vol. 22
, No. 1
, pp. 1
-23
.3.
Dowding
, C. H.
and Huang
, F. C.
, 1993
, “Water Pressure Measurement with Time Domain Reflectometry
,” U.S. Patent Application.4.
Dowding
, C. H.
and Huang
, F. C.
, 1994
a, “Ground Water Pressure Measurements with Time Domain Reflectometry
,” Proceedings
, Symposium and Workshop on Time Domain Reflectometry in Environmental, Infrastructure and Mining Applications
, Northwestern University
, Evanston, IL
, O'Connor
, Dowding
, and Jones
, Eds., U.S. Bureau of Mines
, Special Publication, 19–94 September.5.
Dowding
, C. H.
and Huang
, F. C.
, 1994
, “Early Detection of Rock Movement with Time Domain Reflectometry
,” Journal of Geotechnical Engineering
0733-9410, American Society of Civil Engineers, Vol. 120
, No. 8
, August, pp. 1413
-1427
.6.
Fellner-Feldegg
, H.
, 1969
, “The Measurement of Dielectrics in the Time Domain
,” The Journal of Physical Chemistry
, Vol. 73
, No. 3
, March, pp. 616
-623
.7.
Huang
, F. C.
, 1993
, “Telecommunication Enhancement of Time Domain Reflectometry Measurements
,” Ph.D. dissertation, Department of Civil Engineering, Northwestern University
, Evanston, IL.8.
Huang
, F. C.
, O'Connor
, K. M.
, Yurchack
, D. M.
, and Dowding
, C. H.
, 1993
, NUMOD and NUTSA: Software for Interactive Acquisition and Analysis of Time Domain Reflectometry Measurements
, Information Circular 9346, U.S. Bureau of Mines, Department of the Interior
, Washington, DC
.9.
McComb
, P. S.
, 1992
, “Piezometric Water Pressure Monitoring by Time Domain Reflectometry
,” M.S. thesis, Department of Civil Engineering, Northwestern University
.10.
Ross
, G. F.
, 1974
, “Apparatus and Method for Measuring the Level of a Contained Liquid
,” U.S. Patent No. 3,832,900.11.
Ross
, G. F.
, 1976
, “Apparatus and Method for Sensing a Liquid with a Single Wire Transmission Line
,” U.S. Patent No. 3,995,212.12.
Topp
, G. C.
, Davis
, J. L.
, and Annan
, A. P.
, 1980
. “Electromagnetic Determination of Soil Water Content: Measurement in Coaxial Transmission Lines
,” Water Resource Research
, Vol. 16
, No. 3
, June, pp. 574
-582
.13.
Topp
, G. C.
, Davis
, J. L.
, and Annan
, A. P.
, 1982
, “Electromagnetic Determination of Soil Water Content Using TDR: I. Applications to Wetting Fronts and Steep Gradients
,” Soil Science Society of America Journal
0361-5995, Vol. 46
, pp. 672
-678
.14.
Topp
, G. C.
, Yanuka
, M.
, Zebchuk
, W. D.
, and Zegelin
, S.
, 1988
, “Determination of Electrical Conductivity Using Time Domain Reflectometry: Soil and Water Experiments in Coaxial Lines
,” Water Resource Research
, Vol. 24
, No. 7
, July, pp. 945
-952
.15.
Zegelin
, S. J.
, White
, I.
, and Jenkins
, D. R.
, 1989
, “Improved Field Probes for Soil Water Content and Electrical Conductivity Measurement Using Time Domain Reflectometry
,” Water Resource Research
, Vol. 25
, No. 11
, November, pp. 2367
-2376
.
This content is only available via PDF.
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ASTM International.
You do not currently have access to this content.