Abstract
Mikasa's direct shear apparatus and test procedures are presented. This test apparatus was developed in 1960 to conduct constant volume shear tests, which correspond to undrained shear tests for saturated soils. This apparatus overcomes several defects of the traditional apparatus. The advantages of the direct shear test over the triaxial test are discussed, and typical examples of test results are presented. Some modifications of the test apparatus and procedures permitted automation of constant volume shear tests and unconsolidated undrained shear tests.
Issue Section:
Research Papers
References
1.
Bjerrum
, L.
, 1973
, “Problems of Soil Mechanics and Construction on Soft Clays
,” Proceedings
, 8th International Conference on Soil Mechanics and Foundation Engineering
, Moscow
, Vol. 3
, USSR National Society for Soil Mechanics and Foundation Engineering
, pp. 109
-159
.2.
Dyvik
, R.
, Berre
, T.
, Lacasse
, S.
, and Raadim
, B.
, 1987
, “Comparison of Truly Undrained and Constant Volume Direct Shear Tests
,” Geotechnique
0016-8505, Vol. 37
, No. 1
, pp. 3
-10
.3.
Franke
, R.
, Kiekbusch
, M.
, and Schuppener
, B.
, 1979
, “A New Direct Simple Shear Device
,” Geotechnical Testing Journal
0149-6115, ASTM, 1979
, Vol. 2
, No. 4
, pp. 190
-191
.4.
Japanese Society of Soil Mechanics and Foundation Engineering
, 1969
, “Direct Shear Test
,” Soil Testing
, pp. 361
-397
(in Japanese).5.
Japanese Society of Soil Mechanics and Foundation Engineering
, 1979
, “Direct Shear Test
,” Soil Testing
, pp. 6.2.1-6.2.29 (in Japanese).6.
Japanese Society of Soil Mechanics and Foundation Engineering
, 1990
a, “Direct Shear Test
,” Soil Testing
, pp. 458
-475
(in Japanese).7.
Japanese Society of Soil Mechanics and Foundation Engineering
, 1990
b, “Test Method for Consolidated Undrained Triaxial Compression Test on Soils
,” Soil Testing
, pp. 349
-358
(in Japanese).8.
Mikasa
, M.
, 1960
, “New Direct Shear Test Apparatus
,” Proceedings
, 15th Annual Convention of the Japanese Society of Civil Engineers
, Tokyo
, pp. 45
-48
(in Japanese).9.
Mikasa
, M.
, 1965
, “Test Apparatus and Test Procedures of Triaxial and Direct Shear Testing
,” Proceedings
, 10th Symposium on Soil Testing, Japanese Society of Soil Mechanics and Foundation Engineering
, Tokyo
, pp. 117
-123
(in Japanese).10.
Mikasa
, M.
and Takada
, N.
, 1975
, “Comparison of Triaxial and Direct Shear Tests
,” Proceedings
, 20th Symposium on Unconfined and Triaxial Compression Tests and Their Application
, Japanese Society of Soil Mechanics and Foundation Engineering
, Tokyo
, 1975
, pp. 87
-96
(in Japanese).11.
Mikasa
, M.
, 1987
, “On the Validity of Direct Shear Box Test
,” Proceedings
, 8th Asian Regional Conference on Soil Mechanics and Foundation Engineering
, Vol. 2
, Japanese Society of Soil Mechanics and Foundation Engineering
, pp. 154
-155
.12.
Mikasa
, M.
, Takada
, N.
, and Ohshima
, A.
, 1987
, “In Situ Strength Anisotropy of Clay by Direct Shear Test
,” Proceedings
, 8th Asian Regional Conference on Soil Mechanics and Foundation Engineering
, Vol. 1
, Japanese Society of Soil Mechanics and Foundation Engineering
, pp. 61
-64
.13.
Ohshima
, A.
, Takada
, N.
, and Mikasa
, M.
, 1991
, “Strength Anisotropy of Clay in Slope Stability in Centrifuge
,” Proceedings
, International Centrifuge Conference 91
, Colorado
, A. A. Balkema
, Rotterdam
, pp. 591
-598
.14.
Potts
, D. M.
, Dounias
, G. T.
, and Vaughan
, P. R.
, 1987
, “Finite Element Analysis of the Direct Shear Box Test
,” Geotech
, Vol. 37
, No. 1
, pp. 11
-23
.15.
Takada
, N.
, Mikasa
, M.
, and Tsujimoto
, S.
, 1978
, “Anisotropic Behavior of One-dimensionally Consolidated Clay by Direct Shear
,” Proceedings
, 33rd Annual Convention
, Japanese Society of Civil Engineers
, Vol. 3
, pp. 65
-66
(in Japanese).16.
Takada
, N.
, Ohshima
, A.
, and Okamoto
, S.
, 1990
, “Automation of Constant Volume Control Shear Test Apparatus
,” Proceedings
, 45th Annual Convention
, Japanese Society of Civil Engineers
, Vol. 3
, pp. 212
-213
, (in Japanese).17.
Taylor
, D. W.
, 1952
, “A Direct Shear Test with Drainage Control
,” Proceedings
, Symposium on Direct Shear Testing of Soils
, ASTM
, Philadelphia
, p. 63.
This content is only available via PDF.
All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ASTM International.
You do not currently have access to this content.