An axial flow fan developed in the previous study is tested in order to characterize its performance. The M-fan, a 7.3152 m diameter rotor only axial flow fan was designed to perform well under the challenging operating conditions encountered in air-cooled heat exchangers. Preliminary computational fluid dynamics (CFD) results obtained using an actuator disk model (ADM) as well as a periodic three dimensional model indicate that the fan meets the specified performance targets, with an expected total-to-static efficiency of 59.4% and a total-to-static pressure rise of 114.7 Pa at the operating point. Experimental tests are performed on the M-fan in order to determine its performance across a full range of flow rates. A range of fan configurations are tested in order to ascertain the effect of tip clearance, blade angle, and hub configuration on fan performance. Due to the lack of a suitable facility for testing a large diameter fan, a scaled 1.542 m diameter model is tested on the ISO 5801 type A fan test facility at Stellenbosch University. A Reynolds-averaged Navier–Stokes CFD model representing the M-fan in the test facility is also developed in order to provide additional insight into the flow field in the vicinity of the fan blades. The results of the CFD model will be validated using the experimental data obtained. Both the CFD results and the experimental data obtained are compared to the initial CFD results for the full scale fan, as obtained in the previous study, by means of fan scaling laws. Experimental data indicate that the M-fan does not meet the pressure requirement set out in the initial study at the design blade setting angle of 34 deg. Under these conditions, the M-fan attains a total-to-static pressure rise of 102.5 Pa and a total-to-static efficiency of 56.4%, running with a tip gap of 2 mm. Increasing the blade angle is shown to be a potential remedy, improving the total-to-static pressure rise and efficiency obtained at the operating point. The M-fan is also shown to be highly sensitive to increasing tip gap, with larger tip gaps substantially reducing fan performance. The losses due to tip gap are also shown to be overestimated by the CFD simulations. Both experimental and numerically obtained results indicate lower fan total-to-static efficiencies than obtained in the initial CFD study. Results indicate that the M-fan is suited to its intended application, however, it should be operated with a smaller tip gap than initially recommended and a larger blade setting angle. Hub configuration is also shown to have an influence on fan performance, potentially improving performance at low flow rates.

References

References
1.
van der Spuy
,
S. J.
,
2011
, “
Perimeter Fan Performance in Forced Draught Air-Cooled Steam Condensers
,”
Ph.D. thesis
, Stellenbosch University, Stellenbosch, South Africa.
2.
Minwatercsp
, 2018, “Minwatercsp,” accessed Oct. 20, 2017, https://www.minwatercsp.eu/minwatercsp_project/
3.
Wilkinson
,
M. B.
,
van der Spuy
,
J.
, and
von Backström
,
T. W.
,
2017
, “
The Design of a Large Diameter Axial Flow Fan for Air-Colled Heat Exchanger Applications
,”
ASME
Paper No. GT2017-63331.
4.
Bruneau
,
P. R. P.
,
1994
, “
The Design of a Single Rotor Axial Flow Fan for a Cooling Tower Application
,”
Master's thesis
, University of Stellenbosch, Stellenbosch, South Africa.
5.
Van der Spuy
,
S. J.
,
1997
, “
The Design of a Low-Noise Rotor-Only Axial Flow Fan Series
,”
Master's thesis
, University of Stellenbosch, Stellenbosch, South Africa.
6.
Wallis
,
R. A.
,
1983
,
Axial Flow Fans and Ducts
,
Wiley
,
New York
.
7.
Dixon
,
S. L.
,
1978
,
Fluid Mechanics-Thermodynamics of Turbomachinery
,
3rd ed.
,
Pergamon
,
Oxford, UK
.
8.
Thiart
,
G.
, and
Von Backström
,
T.
,
1993
, “
Numerical Simulation of the Flow Field Near an Axial Flow Fan Operating Under Distorted Inflow Conditions
,”
J. Wind Eng. Ind. Aerodyn.
,
45
(
2
), pp.
189
214
.
9.
BSI Group
,
2007
, “
Industrial Fans—Performance Testing Using Standardized Airways
,” BSI Group, London, Standard Nos. BS EN ISO 5801:2008, BS 848-1:2007.
10.
Louw
,
F. G.
,
Bruneau
,
P. R.
,
von Backström
,
T. W.
, and
van der Spuy
,
S. J.
,
2012
, “
The Design of an Axial Flow Fan for Application in Large Air-Cooled Heat Exchangers
,”
ASME
Paper No. GT2012-69733.
11.
Van Niekerk
,
C.
,
1958
, “
Ducted Fan Design Theory
,”
ASME J. Appl. Mech.
,
25
(
3
), pp.
325
331
.
12.
von Backström
,
T. W.
,
Buys
,
J. D.
, and
Stinnes
,
W. H.
,
1996
, “
Minimization of the Exit Loss of a Rotor-Only Axial Fan
,”
Eng. Optim.
,
26
(
1
), pp.
25
33
.
13.
Drela
,
M.
,
1989
, “
Xfoil: An Analysis and Design System for Low Reynolds Number Airfoils
,”
Low Reynolds Number Aerodynamics
,
Springer
,
Berlin
, pp.
1
12
.
14.
Venter
,
S. J.
, and
Kroger
,
D.
,
1990
, “
The Effectiveness of Axial Flow Fans in A-Frame Plenums
,”
Ph.D. thesis
, University of Stellenbosch, Stellenbosch, South Africa.
15.
Louw
,
F. G.
,
2015
, “
Investigation of the Flow Field in the Vicinity of an Axial Flow Fan During Low Flow Rates
,”
Ph.D. thesis
, Stellenbosch University, Stellenbosch, South Africa.
16.
Shih
,
T.-H.
,
Liou
,
W. W.
,
Shabbir
,
A.
,
Yang
,
Z.
, and
Zhu
,
J.
,
1995
, “
A New k–ε Eddy Viscosity Model for High Reynolds Number Turbulent Flows
,”
Comput. Fluids
,
24
(
3
), pp.
227
238
.
17.
Fukano
,
T.
,
Takamatsu
,
Y.
, and
Kodama
,
Y.
,
1986
, “
The Effects of Tip Clearance on the Noise of Low Pressure Axial and Mixed Flow Fans
,”
J. Sound Vib.
,
105
(
2
), pp.
291
308
.
18.
Wilkinson
,
M. B.
, and
Van der Spuy
,
S. J.
,
2015
, “
The Effect of Fan Tip Configuration on Air-Cooled Condenser Axial Flow Fan Performance
,”
Fan2015
, Lyon, France, Apr. 15–17, pp.
1
12
.
19.
Venter
,
S. J.
, and
Kröger
,
D. G.
,
1992
, “
The Effect of Tip Clearance on the Performance of an Axial Flow Fan
,”
Energy Convers. Manage.
,
33
(
2
), pp.
89
97
.
20.
Bredell
,
J. R.
,
Kröger
,
D.
, and
Thiart
,
G.
,
2006
, “
Numerical Investigation of Fan Performance in a Forced Draft Air-Cooled Steam Condenser
,”
Appl. Therm. Eng.
,
26
(
8–9
), pp.
846
852
.
21.
Stinnes
,
W.
, and
Von Backström
,
T.
,
2002
, “
Effect of Cross-Flow on the Performance of Air-Cooled Heat Exchanger Fans
,”
Appl. Therm. Eng.
,
22
(
12
), pp.
1403
1415
.
You do not currently have access to this content.