Abstract

Centrifugal compressors driven by induction motors are most common in the turbomachinery industry. When sudden transients occur in the driver due to upsets in electrical supply to the motor, the air-gap torque generated by the motor undergoes a transient spike. This in turn gets transmitted through the coupling to the drive-shaft of the driven equipment, causing momentary high spikes in vibration that are torsional in nature, and can sometimes result in shaft torques that can create catastrophic damage to driven equipment components. In order to analytically predict these peak torques that can occur during transients, a complete drive-train torsional model needs to be created for the mechanical system, and the driving torque values need to be derived from the motor electrical system of equations. Various line faults are possible with induction motor driven equipment. A generalized analytical procedure based on motor electrical parameters to predict the peak shaft torques of compressor drive shafts is investigated in this paper. The effects of shaft transients due to 3-phase short circuits and reclosures are analyzed. The simulation has been performed for an industrial compressor train, and has been presented from a mechanical system point of view, rather than electrical. Comparisons and inferences are also made based on the simulation results.

References

1.
Daugherty
,
R. H.
, 1982, “
Analysis of Transient Electrical Torques and Shaft Torques in Induction Motors as a Result of Power Supply Disturbances
,”
IEEE Trans. Power Appar. Syst.
,
8
, pp.
2826
2836
.
2.
Daugherty
,
R. H.
, 1990, “
Bus Transfer of AC Induction Motors: A Perspective
,”
IEEE Trans. Ind. Appl.
,
26
(
5
), pp.
935
943
.
3.
Mruk
,
G.
, and
Halloran
,
J.
, 1988, “
Torques Due to Electrical Reclosures for Induction Motor Driven Centrifugal Compressors
,”
Proceedings of the Vibration Institute 12th Annual Meeting, May 25–27
, pp.
185
189
.
4.
Shaltout
,
A.
, and
Al-Omoush
,
M.
, 1996, “
Reclosing Torques of Large Induction Motors With Trapped Flux
,”
IEEE Trans. Energy Convers.
,
11
(
1
), pp.
84
90
.
5.
Hizume
,
A.
, 1975, “
Transient Torsional Vibration of Steam Turbine and Generator Shafts Due to High Speed Reclosing of Electric Power Lines
,”
ASME 75-DET-71
, pp.
968
979
.
6.
Melfi
,
M.
, and
Umans
,
S.
, 2010, “
Transients During Line-Starting of Squirrel Cage Induction Motors
,”
Proceedings of the IEEE IAS PCIC 57th Annual Conference
, Paper No. PCIC-2010-23.
7.
Krause
,
P.
,
Wasynczuk
,
O.
, and
Sudhoff
,
S.
, 1994,
Analysis of Electric Machinery
,
IEEE Press
,
New York
.
8.
Vance
,
J.
, 1988,
Rotordynamics of Turbomachinery
,
Wiley
,
New York
, Chap. 3.
9.
Fitzgerald
,
A. E.
,
Kinglsey
,
C.
Jr.
, and
Umans
,
S.
, 1990,
Electric Machinery
, 5th ed.,
McGraw-Hill
,
New York
.
You do not currently have access to this content.