The evaporative inlet cooling systems do not work well in humid areas. However, desiccant wheels can be used to dehumidify the air before passing it through the evaporative cooler. A previous study of combined direct and indirect evaporative coolers showed that a single desiccant wheel does not offer much higher effectiveness compared with the multistage evaporative systems. In this paper, additional dehumidification and indirect evaporative cooling stages are added to increase the effectiveness of the desiccant-based inlet cooling. A typical gas turbine cycle along with an industrial gas turbine with actual performance curves are used to study the performance of the proposed system in three different climatic conditions. It is shown that the added stages substantially improve the effectiveness of the desiccant-based inlet cooling.

1.
Boyce
,
M. P.
, 2002,
Gas Turbine Engineering Handbook
, 2nd ed.,
Gulf Professional
,
Boston, MA
.
2.
Alhazmy
,
M. M.
, and
Najjar
,
Y. S. H.
, 2004, “
Augmentation of Gas Turbine Performance Using Air Coolers
,”
Appl. Therm. Eng.
1359-4311,
24
(
2–3
), pp.
415
429
.
3.
Zadpoor
,
A. A.
, and
Golshan
,
A. H.
, 2006, “
Performance Improvement of a Gas Turbine Cycle by Using a Desiccant-Based Evaporative Cooling System
,”
Energy
,
31
(
14
), pp.
2652
2664
. 0360-5442
4.
Camargo
,
J. R.
,
Ebinuma
,
C. D.
, and
Silveira
,
J. L.
, 2003, “
Thermoeconomic Analysis of an Evaporative Desiccant Air Conditioning System
,”
Appl. Therm. Eng.
,
23
(
12
), pp.
1537
1549
. 1359-4311
5.
Liu
,
W.
,
Lian
,
Z.
,
Radermacher
,
R.
, and
Yao
,
Y.
, 2007, “
Energy Consumption Analysis on a Dedicated Outdoor Air System With Rotary Desiccant Wheel
,”
Energy
,
32
(
9
), pp.
1749
1760
. 0360-5442
6.
Daou
,
K.
,
Wang
,
R. Z.
, and
Xia
,
Z. Z.
, 2006, “
Desiccant Cooling Air Conditioning: A Review
,”
Renewable Sustainable Energy Rev.
1364-0321,
10
(
2
), pp.
55
77
.
7.
Lefebvre
,
A. H.
, 1998,
Gas Turbine Combustion
,
Taylor & Francis
,
London
.
8.
Ameri
,
M.
,
Hejazi
,
S. H.
, and
Montaser
,
K.
, 2005, “
Performance and Economic of the Thermal Energy Storage Systems to Enhance the Peaking Capacity of the Gas Turbines
,”
Appl. Therm. Eng.
,
25
(
2–3
), pp.
241
251
. 1359-4311
9.
Chaker
,
M.
,
Meher-Homji
,
C. B.
,
Mee
,
T.
, and
Nicholson
,
A.
, 2003, “
Inlet Fogging of Gas Turbine Engines Detailed Climatic Analysis of Gas Turbine Evaporation Cooling Potential in the USA
,”
ASME J. Eng. Gas Turbines Power
0742-4795,
125
(
1
), pp.
300
309
.
10.
Corporation
,
R. D.
, 2003,
Cooling, Heating, and Power for Industry: A Market Assessment
,
U.S. Department of Energy
,
Vienna, Austria
.
11.
Gareta
,
R.
,
Romeo
,
L. M.
, and
Gil
,
A.
, 2004, “
Methodology for the Economic Evaluation of Gas Turbine Air Cooling Systems in Combined Cycle Applications
,”
Energy
0360-5442,
29
(
11
), pp.
1805
1818
.
12.
Mazzei
,
P.
,
Minichiello
,
F.
, and
Palma
,
D.
, 2002, “
Desiccant HVAC Systems for Commercial Buildings
,”
Appl. Therm. Eng.
,
22
(
5
), pp.
545
560
. 1359-4311
13.
Wilson
,
A.
, 2003,
Greening Federal Facilities
,
U.S. Department of Energy
,
Brattleboro, VT
.
You do not currently have access to this content.