Inlet fogging of gas turbine engines has attained considerable popularity due to the ease of installation and the relatively low first cost compared to other inlet cooling methods. With increasing demand for power and with shortage envisioned especially during the peak load times during the summers, there is a need to boost gas turbine power. There is a sizable evaporative cooling potential throughout the world when the climatic data is evaluated based on an analysis of coincident wet bulb and dry bulk information. These data are not readily available to plant users. In this paper, a detailed climatic analysis is made of 122 locations in the U.S. to provide the hours of cooling that can be obtained by direct evaporative cooling. These data will allow gas turbine operators to easily make an assessment of the economics of evaporative cooling. The paper also covers an introduction to direct evaporative cooling and the methodology and data analysis used to derive the cooling potential in different regions of the U.S. Simulation runs have been made for gas turbine simple cycles using a reference plant based on a GE Frame 7111EA gas turbine at the 122 locations studied in the U.S. to provide a feel for the sensitivity of operation with inlet fogging.

1.
Mc Neilly, D., 2000, “Application of Evaporative Coolers for Gas Turbine Power Plants,” ASME Paper No. 2000-GT-303.
2.
Kitchen, B. J. and Ebeling, J. A., 1995, “QUALIFYING Combustion Turbines for Inlet Air Cooling Capacity Enhancement,” ASME Paper No. 95-GT-26.
3.
Meher-Honiji, C. B., and Mee, T. R., 2000, “Inlet Fogging of Gas Turbine Engines-Part A: Theory Psychrometrics and Fog Generation and Part B: Practical Considerations, Control and O&M Aspects,” ASME Paper Nos. 2000-GT-307 and 200-GT-308.
4.
Giourof, A., 1995, “Gas, Turbine Inlet Air Cooling: You Can Almost Pick Your Payback,” Power, May.
5.
Guinn, G. R., 1993, “Evaluation of Combustion Gas Turbine Inlet Air Precooling for Time Varying Annual Climatic Conditions,” ASME Cogen-Turbo 1993, Bournmouth, UK, Sept. 21–23, 1993, IGTI-Vol. 8, ASME, New York.
6.
Johnson, R. S., 1988, “The Theory and Operation of Evaporative Coolers for Industrial Gas Turbine Installations,” ASME Paper No. 83-GT-41.
7.
Utamura, M., Ishikawa, A., Nishimura, Y., and Ando, N. 1996, “Economics of Gas Turbine Inlet Air Cooling System for Power Enhancement,” ASME Paper No. 96-GT-515.
8.
Ondryas, I. S., “Options in Gas Turbine Power Augmentation Using Inlet Air Chilling,” ASME Paper 90-GT-250.
9.
Van Der Linden, S., and Searles, D. E., 1996, “Inlet Conditioning Enhances Performance of Modern Combined Cycle Plants for Cost—Effective Power Generation,” ASME Paper No. 96-GT-298.