The flow discharged from centrifugal impellers is highly distorted and its behavior in the diffuser could be expected to have a determining effect on the performance of the compressor. The present work sets out to investigate this. The experimental work reported in this paper was designed to investigate the interaction between the vaned diffuser and the impeller. Unsteady measurements of velocity and wall static pressure were made at numerous positions in a vaned diffuser using an on-line data logging system. Experiments were carried out at a range of flow coefficients for three diffusers with 10, 20, and 30 vanes set at each of three different radius ratios, 1.04, 1.1, and 1.2. A limited number of experiments were also carried out with restaggered diffuser vanes and as a reference case extensive measurements were made in a vaneless diffuser build. The impeller, which was designed for a pressure ratio of 4.6, was run at low speed (3000 rpm) after modification to make its overall diffusion equivalent to that at the high speed for which it was designed. The circumferential distortion from the impeller was attenuated very rapidly in the entrance region of the diffuser vanes and suprisingly had only minor effects on the flow inside the vaned diffuser passage. The effect of the diffuser vanes on the flow discharged from the impeller was evident and reversal of flow back into the impeller was detected when the diffuser vanes were close to the impeller and the flow rate was not very high. The time-mean total and static pressure at impeller outlet were found to vary over the pitch of a diffuser vane, and a variation in the strength of the impeller wake was also observed.
Skip Nav Destination
Article navigation
April 1984
Research Papers
Experimental Study of Centrifugal Impeller Discharge Flow in Vaneless and Vaned Diffusers
M. Inoue,
M. Inoue
Komatsu Ltd., Hiratsuka, Kanagawa, Japan
Search for other works by this author on:
N. A. Cumpsty
N. A. Cumpsty
Whittle Laboratory, University of Cambridge, England
Search for other works by this author on:
M. Inoue
Komatsu Ltd., Hiratsuka, Kanagawa, Japan
N. A. Cumpsty
Whittle Laboratory, University of Cambridge, England
J. Eng. Gas Turbines Power. Apr 1984, 106(2): 455-467 (13 pages)
Published Online: April 1, 1984
Article history
Received:
November 9, 1982
Online:
October 15, 2009
Citation
Inoue, M., and Cumpsty, N. A. (April 1, 1984). "Experimental Study of Centrifugal Impeller Discharge Flow in Vaneless and Vaned Diffusers." ASME. J. Eng. Gas Turbines Power. April 1984; 106(2): 455–467. https://doi.org/10.1115/1.3239588
Download citation file:
Get Email Alerts
Study of Injector Geometry and Parcel Injection Location on Spray Simulation of the Engine Combustion Network Spray G Injector
J. Eng. Gas Turbines Power (July 2023)
Fully Coupled Analysis of Flutter Induced Limit Cycles: Frequency Versus Time Domain Methods
J. Eng. Gas Turbines Power (July 2023)
Impact of Ignition Assistant on Combustion of Cetane 30 and 35 Jet-Fuel Blends in a Compression-Ignition Engine at Moderate Load and Speed
J. Eng. Gas Turbines Power (July 2023)
Related Articles
Clearance Effects on the Evolution of the Flow in the Vaneless Diffuser of a Centrifugal Compressor at Part Load Condition
J. Turbomach (July,2008)
A Study on Centrifugal Impeller and Diffuser Flow
J. Eng. Power (October,1981)
Investigation of Unsteady Flow Field in a Vaned Diffuser of a Transonic Centrifugal Compressor
J. Turbomach (October,2007)
Instantaneous Measurements in the Jet-Wake Discharge Flow of a Centrifugal Compressor Impeller
J. Eng. Power (July,1975)
Related Proceedings Papers
Related Chapters
Other Components and Variations
Axial-Flow Compressors
Introduction
Design and Analysis of Centrifugal Compressors
Aerodynamic Performance Analysis
Axial-Flow Compressors