Abstract

Forensic analysis of glass samples was performed in different laboratories within the NITE-CRIME (Natural Isotopes and Trace Elements in Criminalistics and Environmental Forensics) European Network, using a variety of Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) systems. The main objective of the interlaboratory tests was to cross-validate the different combinations of laser ablation systems with different ICP-MS instruments. A first study using widely available samples, such as the NIST SRM 610 and NIST SRM 612 reference glasses, led to deviations in the determined concentrations for trace elements amongst the laboratories up to 60%. Extensive discussion among the laboratories and the production of new glass reference standards (FGS 1 and FGS 2) established an improved analytical protocol, which was tested on a well-characterized float glass sample (FG 10-1 from the BKA Wiesbaden collection). Subsequently, interlaboratory tests produced improved results for nearly all elements with a deviation of <10%, demonstrating that LA-ICP-MS can deliver absolute quantitative measurements on major, minor and trace elements in float glass samples for forensic and other purposes.

References

1.
Watling
RJ
,
Lynch
BF
,
Herring
D
.
Use of laser ablation inductively coupled plasma mass spectrometry for fingerprinting scene of crime evidence
.
J Anal At Spectrom
 0267-9477
1997
;
12
:
195
203
.
2.
Duckworth
DC
,
Morton
SJ
,
Bayne
CK
,
Koons
RD
,
Montero
S
,
Almirall
JR
.
Forensic glass analysis by ICP-MS: a multi-element assessment of discriminating power via analysis of variance and pairwise comparisons
.
J Anal At Spectrom
 0267-9477
2002
;
17
:
662
8
.
3.
Hordijk
M
,
Wiarda
W
,
de Joode
P
,
van der Peijl
GJQ
,
Montero
S
.
LAICP-MS method for the elemental profiling of forensic glass: A study of a float glass sample set collected in the Netherlands
.
Forensic Sci Int
 0379-0738
2003
;
136
:
358
9
.
4.
Montero
S
,
Hobbs
AL
,
French
TA
,
Almirall
AR
.
Elemental analysis of glass fragments by ICP-MS as evidence of association: Analysis of a case
.
J Forensic Sci
 0022-1198
2003
;
48
:
1101
7
.
5.
Trejos
T
,
Montero
S
,
Almirall
JR
.
Analysis and comparison of glass fragments by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and ICP-MS
.
Anal Bioanal Chem
 1618-2642
2003
;
376
:
1255
64
.
6.
Koons
RD
,
Buscaglia
J
.
The forensic significance of glass composition and refractive index measurements
.
J Forensic Sci
 0022-1198
1999
;
44
:
496
503
.
7.
Curran
JM
,
Hicks
T
,
Buckleton
JS
.
Forensic interpretation of glass evidence
.
Boca Raton
:
CRC Press
,
2000
;17.
8.
Parouchais
T
,
Warner
IM
,
Palmer
LT
,
Kobus
H
.
The analysis of small glass fragments using inductively coupled plasma mass spectrometry
.
J Forensic Sci
 0022-1198
1996
;
41
:
351
60
.
9.
Becker
S
,
Gunaratnam
L
,
Hicks
T
,
Stoecklein
W
,
Warman
G
.
The differentiation of float glass using refractive index and elemental analysis: comparisons of techniques
.
Probl Forensic Sci
2001
;
XLVII
:80– 92.
10.
Buscaglia
J
.
Elemental analysis of small glass fragments in forensicscience
.
Anal Chim Acta
 0003-2670
1994
;
288
: 17–24.
11.
Almirall
JR
.
Elemental analysis of glass fragments
. In:
Forensic examination of glass and paint: Analysis and interpretation
.
London
,
New York
:
Taylor & Francis
,
2001
; 65–83.
12.
Aeschliman
DB
,
Bajic
SJ
,
Baldwin
DP
,
Houk
RS
.
Multivariate pattern matching of trace elements in solids by laser ablation inductively coupled plasma-mass spectrometry: Source attribution and preliminary diagnosis of fractionation
.
Anal Chem
 0003-2700
2004
;
76
:
3119
25
.
13.
Strubel
C
,
Meckel
L
,
Effenberger
R
.
Determination of the composition of glass, glass-ceramics and glass raw materials with laser-ICP-MS
.
Glastech
 0017-1050
1999
;
72
:
15
20
.
14.
Caddy
B
.
Forensic examination of glass and paint: Analysis and interpretation
.
London
,
New York
:
Taylor & Francis
,
2001
.
15.
Gao
S
,
Liu
XM
,
Yuan
HL
,
Hattendorf
B
,
Günther
D
,
Chen
L
,
Hu
SH
.
Determination of forty two major and trace elements in USGS and NIST SRM glasses by laser ablation-inductively coupled plasma- mass spectrometry
.
Geostand Newsl
2002
;
26
:
181
96
.
16.
Pearce
NJG
,
Perkins
WT
,
Westgate
JA
,
Gorton
MP
,
Jackson
SE
,
Neal
CR
,
Chenery
SP
.
A compilation of new and published major and trace element data for NIST SRM 610 and NIST SRM 612 glass reference materials
.
Geostand Newsl
1997
;
21
:
115
44
.
17.
Hollocher
K
,
Ruiz
J
.
Major and trace-element determinations on NIST glass standard reference material-611, material-612, material-614, and material-1834 by ICP-MS
.
Geostand Newsl
1995
;
19
:
27
34
.
18.
Becker
S
,
Ducking
M
,
Watzke
P
,
Stoecklein
W
.
Laser ablation in forensic glass analysis: The use of matrix matched standards for quantitative float glass analysis
.
Forensic Sci Int
 0379-0738
2003
;
136
:361.
19.
Longerich
HP
,
Jackson
SE
,
Günther
D
.
Laser ablation inductively coupled plasma mass spectrometric transient signal data acquisition and analyte concentration calculation
.
J Anal At Spectrom
 0267-9477 https://doi.org/10.1039/ja9961100899
1996
;
11
:
899
904
.
20.
Bleiner
D
,
Günther
D
.
Theoretical description and experimental observation of aerosol transport processes in laser ablation inductively coupled plasma mass spectrometry
.
J Anal At Spectrom
 0267-9477
2001
;
16
:
449
56
.
21.
Almirall
JR
,
Furton
KG
,
Duckworth
DC
,
Morton
SJ
,
Bayne
CK
,
Montero
S
.
Trace-elemental analysis of forensic glass samples by ICP-MS
.
Abstr Pap Amer Chem Soc
 0065-7727
2000
;
219
:
108
-
ANYL
.
22.
Horn
I
,
Guillong
M
,
Günther
D
.
Wavelength dependant ablation rates for metals and silicate glasses using homogenized laser beam profiles- implications for LA-ICP-MS
.
Appl Surf Sci
 0378-5963
2001
;
182
:
91
102
.
23.
Gonzalez
J
,
Mao
XL
,
Roy
J
,
Mao
SS
,
Russo
RE
.
Comparison of 193, 213 and 266 nm laser ablation ICP-MS
.
J Anal At Spectrom
 0267-9477
2002
;
17
: 1108–13.
24.
Guillong
M
,
Horn
I
,
Günther
D
.
A comparison of 266 nm, 213 nm and 193 nm produced from a single solid state Nd: YAG laser for laser ablation ICP-MS
.
J Anal At Spectrom
 0267-9477
2003
;
18
:
1224
30
.
25.
Rodushkin
I
,
Axelsson
MD
,
Malinovsky
D
,
Baxter
DC
.
Analyte- and matrix-dependent elemental response variations in laser ablation inductively coupled plasma mass spectrometry—Part [2] Implications for multielement analyses
.
J Anal At Spectrom
 0267-9477
2002
;
17
:
1231
9
.
26.
Guillong
M
,
Kuhn
HR
,
Günther
D
.
Application of a particle separation device to reduce inductively coupled plasma-enhanced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry
.
Spectrochim Acta B
 0584-8547
2003
;
58
:
211
20
.
27.
Kuhn
HR
,
Guillong
M
,
Günther
D
.
Size-related vaporisation and ionisation of laser-induced glass particles in the inductively coupled plasma
.
Anal Bioanal Chem
 1618-2642
2004
;
378
:
1069
74
.
28.
Trejos
T
,
Almirall
JR
.
Effect of fractionation on the forensic elemental analysis of glass using laser ablation inductively coupled plasma mass spectrometry
.
Anal Chem
 0003-2700
2004
;
76
:
1236
42
.
29.
Longerich
HP
,
Günther
D
,
Jackson
SE
.
Elemental fractionation in laser ablation inductively coupled plasma mass spectrometry
.
Fresenius J Anal Chem
 0937-0633
1996
;
355
:
538
42
.
30.
Becker
S
,
Chadzelek
A
,
Stoecklein
W
.
Classification of float glasses with respect to their origin by chemometric analysis of elemental concentrations and the use of LA-ICP-MS as a tool in forensic science
.
Proceedings of the European Winter Conference on Plasma Spectrochemistry, January 10–15, 1999
, organized and published by the
Université Pau et des Pays de l'Adour
,
64016 Pau, France
,
113
4
.
31.
Trejos
T
,
Almirall
JR
.
Sampling strategies for the analysis of glass fragments by LA-ICP-MS
. Part II:
sample size and sample shape considerations
.
Talanta
 0039-9140, in press.
This content is only available via PDF.
You do not currently have access to this content.