Abstract

A case is reported in which computer fire modeling was used to reevaluate a fire that killed three fire fighters. NIST's Fire Dynamics Simulator (FDS) was employed to model the fire in order to estimate the concentration of carbon monoxide present in the dwelling, which was the immediate cause of death of two of the fire fighters, who appear to have removed their face pieces in order to share available air. This estimate, along with an assumed respiration volume and known blood carboxyhemoglobin, was plugged into a standard equation to estimate the time of exposure. The model indicated that 27 min into the fire, the carbon monoxide concentration had already reached approximately 3600 ppm. At this concentration, and a respiration of 70 L/min, an estimated 3 to 8 min of exposure would have been required to accumulate the concentrations of carboxyhemoglobin (49, 44, and 10%) measured on the fire fighters at autopsy.

References

1.
McGrattan
K B
,
Forney
G P
,
Prasad
K
,
Floyd
J E
,
Hostikka
S
.
Fire Dynamics Simulator (Version 3) user's guide
. Gaithersburg:
National Institute of Standards and Technology
;
2002
Report No.: NISTIR 6784.
2.
Purser
D A
.
Toxicity assessment of combustion products
. In:
DiNenno
P J
,
Beyler
C L
,
Custer
RL P
,
Walton
W D
,
Watts
J M
,
Drysdale
D
, et al., editors.
SFPE handbook of fire protection engineering
. 2nd ed.
Quincy
:
National Fire Protection Association
,
1995
;2.85–2.146.
3.
World Health Organization
.
Carbon monoxide. Environmental health criteria 213
.
Geneva
:
World Health Organization
,
1999
.
4.
Routley
J G
.
Three fire fighters die in Pittsburgh house fire
. Pittsburgh:
Federal Emergency Management Agency
;
1995
Report No.: 078 of the Major Fire Investigation Project.
5.
Stewart
R D
,
Peterson
J E
,
Fisher
T N
,
Hosko
M J
,
Baretta
E D
,
Dodd
H C
, et al
.
Experimental human exposure to high concentrations of carbon monoxide
.
Arch Environ Hlth
 0003-9896
1973
;
26
:
1
7
.
6.
McHardy
GJ R
,
Shirling
D
,
Passmore
R
.
Basic techniques in human metabolism and respiration
.
Oxford
:
Blackwell Scientific Publications, Ltd.
,
1967
.
7.
McGrattan
K B
,
Baum
H R
,
Tehm
R G
,
Hamins
A
,
Forney
G
.
Fire dynamics simulator—technical reference guide
. Gaithersburg:
National Institute of Standards and Technology
,
2000
Report No.: NISTIR 6467.
8.
McGrattan
K B
,
Baum
H R
,
Rehm
R G
.
Large eddy simulations of smoke movement
.
Fire Safety Journal
 0379-7112 https://doi.org/10.1016/S0379-7112(97)00041-6
1998
;
30
:
161
78
.
9.
McGrattan
K B
,
Hamins
A
,
Stroup
D
.
Sprinkler, smoke & heat vent, draft curtain interaction—large scale experiments and model development
. Gaithersburg:
National Institute of Standards andTechnology
,
1998
Report No.: NISTIR6196-1.
10.
Madrzykowski
D
,
Vettori
R L
.
Simulation of the dynamics of the fire at 3146 Cherry Road NE, Washington D.C. on May 30, 1999
. Gaithersburg:
National Institute of Standards and Technology
,
2000
Technical Report No.: NISTIR6510.
11.
Madrzykowski
D
,
Forney
G P
,
Walton
W D
.
Simulation of the dynamics of the fire in a two-story duplex, Iowa, December 22, 1999
. Gaithersburg:
National Institute of Standards and Technology
,
2000
Technical Report No.: NISTIR6854.
12.
Rehm
R G
.
Pitts
W M
,
Baum
H R
,
Evans
D D
,
Prasad
K
,
McGrattan
K B
, et al
.
Initial model for fires at the World Trade Center Towers
. Gaithersburg:
National Institute of Standards and Technology
,
2000
Technical Report No.: NISTIR6879.
13.
Robertson
J L
,
Stambaugh
H
.
Fire at Watts Bar Hydroelectric Plant
. Emmitsburg:
Major Fires Investigation Project, U.S. Fire Administration, Federal Emergency Management Agency
,
2003
Report No.: USFA-TR-147.
14.
Mowrer
F W
.
The right tool for the job
.
J Fire Protection Engineering
 1042-3915
2002
;
13
:
39
44
.
This content is only available via PDF.