Abstract

Time-resolved luminescence imaging using a computer-interfaced gateable digital camera is shown to be useful for laser fingerprint development on strongly luminescent substrates. The system design is optimized for rare earth fingerprint treatment chemistry. System specifications are detailed and operation is discussed. Other potential applications include DNA typing and bioassay.

References

1.
Menzel
,
E. R.
, “
Laser Detection Of Latent Fingerprints—Treatment With Phosphorescers
.”
Journal of Forensic Sciences
 0022-1198, Vol.
24
, No.
3
,
1979
, pp.
582
-
585
.
2.
Mitchell
,
K. E.
and
Menzel
,
E. R.
, “
Time-Resolved Luminescence Imaging: Application To Latent Fingerprint Detection
.”
Fluorescence Detection III, SPIE Proceedings
,
E. R.
Menzel
, Ed., Vol.
1054
,
1989
, pp.
191
-
195
.
3.
Menzel
,
E. R.
, “
Laser Detection Of Latent Fingerprints: Tris(2,2′-Bipyridyl)Ruthenium(II) Chloride Hexahydrate As A Staining Dye For Time-Resolved Imaging
,”
Fluorescence Detection II, SPIE Proceedings
,
E. R.
Menzel
, Ed., Vol.
910
,
1988
, pp.
45
-
51
.
4.
Menzel
,
E. R.
and
Mitchell
,
K. E.
, “
Intramolecular Energy Transfer In The Europium-Ruhemann's Purple Complex: Application To Latent Fingerprint Detection
,”
Journal of Forensic Sciences
 0022-1198, Vol.
35
, No.
1
,
01
1989
, pp.
35
-
45
.
5.
Mekkaoui
,
A. I.
and
Menzel
,
E. R.
, “
Spectroscopy Of Rare Earth-Ruhemann's Purple Complexes
,”
Journal of Forensic Sciences
 0022-1198, Vol.
38
, No.
3
,
05
1993
, pp.
506
-
520
.
6.
Kaymaz
,
E.
and
Mitra
,
S.
, “
A Novel Approach To Fourier Spectral Enhancement Of Laser-Luminescent Fingerprint Images
,”
Journal of Forensic Sciences
 0022-1198, Vol.
38
, No.
3
,
05
1993
, pp.
530
-
541
.
7.
Diamandis
,
E. P.
,
Morton
,
R. C.
,
Reichstein
,
E.
, and
Khosravi
,
M. J.
, “
Multiple Fluorescence Labeling With Europium Chelators. Application To Time-Resolved Fluoroimmunoassays
,”
Analytical Chemistry
 0003-2700, Vol.
61
, No.
1
,
1989
, pp.
48
-
53
.
8.
Kronem Applications Note
, No.
1
,
11
1990
, No.
2
,
12
1990
, No.
3
,
02
1991
,
Kronem Systems, Inc.
,
6850 Goreway Drive, Mississauga, Ontario, Canada, L4V 1P1
.
9.
Matthews
,
J. A.
and
Kricka
,
L. J.
, “
Analytical Strategies For The Use Of DNA Probes
,”
Analytical Biochemistry
 0003-2697, Vol.
169
,
1988
, pp.
1
-
25
.
10.
Soini
,
E.
and
Lovgren
,
T.
, “
Time-Resolved Fluorescence Of Lanthanide Probes And Applications In Biotechnology
,”
CRC Critical Reviews in Analytical Chemistry
, Vol.
18
,
1987
, pp.
105
-
154
.
11.
Diamandis
,
E. P.
, “
Immunoassays With Time-Resolved Fluorescence Spectroscopy: Principles And Applications
,”
Clinical Biochemistry
 0009-9120, Vol.
21
,
1988
, pp.
139
-
150
.
12.
Diamandis
,
E. P.
,
Evangelista
,
R. A.
,
Pollak
,
A.
,
Templeton
,
E. F.
, and
Lowden
,
J. A.
, “
Time-Resolved Fluoroimmunoassays With Europium Chelates As Labels
,”
American Clinical Laboratory
 1041-3235,
02
1989
, pp.
26
-
28
.
13.
Soini
,
E.
and
Kojola
,
H.
, “
Time-Resolved Fluorometer For Lanthanide Chelates—A New Generation Of Nonisotopic Immunoassays
,”
Clinical Chemistry
 0009-9147, Vol.
29
,
1983
, pp.
65
-
68
.
This content is only available via PDF.