The loss coefficients for smooth, sharp-edged tees of circular cross-section with the area ratio of 11.44 were determined experimentally for five branch angles which ranged from 45 deg to 135 deg giving special consideration to all configurations of flow through the tees. The Reynolds number, in the leg carrying the combined flow, was kept to a constant value, i.e., for the branch pipe and for the main pipe, respectively. The equations for loss coefficients developed from the continuity, energy, and momentum principles give good agreement with the experimental results for tees with large area ratios provided that correction factors are introduced. The correction factors were determined by the analysis of the experimental data with the relative uncertainties from 0.9 to 3.3% according to the configurations of flow. The results constitute a useful guide to the determination of the loss coefficients for tees with large area ratios.
Skip Nav Destination
Article navigation
January 2005
Technical Papers
Energy Losses at Tees With Large Area Ratios
Kenji Oka, Associate Professor,,
Kenji Oka, Associate Professor,
Department of Mechanical Engineering, College of Engineering, Nihon University, Ko¯riyama, 963-8642, Japan
Search for other works by this author on:
Hidesato Ito¯, Emeritus Professor, To¯hoku University, Former Professor, Nihon University,
Hidesato Ito¯, Emeritus Professor, To¯hoku University, Former Professor, Nihon University,
3-5-13, Kuromatsu, Izumi-ku, Sendai, 981-8006, Japan
Search for other works by this author on:
Kenji Oka, Associate Professor,
Department of Mechanical Engineering, College of Engineering, Nihon University, Ko¯riyama, 963-8642, Japan
Hidesato Ito¯, Emeritus Professor, To¯hoku University, Former Professor, Nihon University,
3-5-13, Kuromatsu, Izumi-ku, Sendai, 981-8006, Japan
Contributed by the Fluids Engineering Division for publication on the JOURNAL OF FLUIDS ENGINEERING. Manuscript received by the Fluids Engineering Division October 3, 2002; revised manuscript received August 17, 2004. Review Conducted by: M. Otugen.
J. Fluids Eng. Jan 2005, 127(1): 110-116 (7 pages)
Published Online: March 22, 2005
Article history
Received:
October 3, 2002
Revised:
August 17, 2004
Online:
March 22, 2005
Citation
Oka, K., and Ito¯, H. (March 22, 2005). "Energy Losses at Tees With Large Area Ratios ." ASME. J. Fluids Eng. January 2005; 127(1): 110–116. https://doi.org/10.1115/1.1852475
Download citation file:
Get Email Alerts
Related Articles
Computational Fluid Dynamics Application of the Diffusion-Inertia Model to Bubble Flows and Boiling Water Problems
J. Eng. Gas Turbines Power (December,2010)
Closure to “Discussion: ‘A Novel Explicit Equation for Friction Factor in Smooth and Rough Pipes’ ” ( 2011, ASME J. Fluids Eng., 133, p. 015501 )
J. Fluids Eng (January,2011)
Linear Instability of Entry Flow in a Pipe
J. Fluids Eng (October,2007)
Modeling the Wall Pressure Spectrum in Turbulent Pipe Flows
J. Fluids Eng (March,2006)
Related Proceedings Papers
Related Chapters
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition
Heat Generated in Pipe Flows Due to Friction
Everyday Heat Transfer Problems: Sensitivities to Governing Variables
Neural Network and Genetic Programming in Pressure Loss Estimation in Eccentric Pipe Flow
Intelligent Engineering Systems through Artificial Neural Networks Volume 18