Open cycle feed systems featuring a deaerator followed by the boiler feed pumps have been subject to unexpected loss in net positive suction head during transient operation. This has been traced to separation at the deaerator storage tank drain and the formation of a steam/water interface in the downcomer to the pumps. The outflow at separation when the storage tank water is subcooled is generally much greater than the maximum suction flow corresponding to the unit rating, but when the tank water boils, as during transients, it may be very much less. Thus with a high suction flow in the boiling mode, the new interface may descend in the downcomer to result in feed pump cavitation, pressure imbalance, vapor locking, severe vibration, damage to the pump and an inability to maintain forward flow. Model tests have been conducted to establish the criterion for the separation in terms of the critical outflow for specific operating conditions as a function of geometric ratios involving tank-water depth and tank/downcomer dimensions. The data obtained although scattered are in general agreement with the data from actual plant and may be used to assess safe operating parameters.
Skip Nav Destination
Article navigation
December 1988
Research Papers
Studies of Power Station Feed Pump Loss of Suction Pressure Incidents
R. R. Cranfield
R. R. Cranfield
Central Electricity Generating Board, Technology Planning and Research Division, Southampton, UK
Search for other works by this author on:
R. R. Cranfield
Central Electricity Generating Board, Technology Planning and Research Division, Southampton, UK
J. Fluids Eng. Dec 1988, 110(4): 453-461 (9 pages)
Published Online: December 1, 1988
Article history
Received:
April 30, 1987
Online:
October 26, 2009
Citation
Cranfield, R. R. (December 1, 1988). "Studies of Power Station Feed Pump Loss of Suction Pressure Incidents." ASME. J. Fluids Eng. December 1988; 110(4): 453–461. https://doi.org/10.1115/1.3243577
Download citation file:
16
Views
Get Email Alerts
Cited By
Related Articles
Design of Suction Piping and Deaerator Storage Capacity to Protect Feed Pumps
J. Eng. Power (January,1961)
Flow Visualization of Submerged Steam Jet in Subcooled Water
J. Heat Transfer (February,2016)
Analysis of Power Plant Deaerator Under Transient Turbine Loads
J. Eng. Power (July,1973)
Related Proceedings Papers
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach