In this study, “energy efficiency” study has been performed for a natural gas fuelled boiler, operating at 42,000 kPa pressure and 713.15 K temperature, with a nominal capacity of 33.33 kg/s steam. Within this frame, temperature, pressure, velocity, and gas analysis measurements have been made, and energy, mass balances, and exergy analysis have been formed. Then, the efficiency of boiler, potential energy saving options and savings quantities, investment costs, and payback period for normal operating conditions have been calculated from the energy and mass balances. Implementation cost is required only for reducing air leakages in the rotary type air heater and surface thermal losses. The investment cost for reducing air leakage in the rotary type air heater to the acceptable limits (10%) is 600,000 USD. Under these circumstances, the payback period of this investment cost is about fifteen months.
Skip Nav Destination
durmus.kaya@mam.gov.tr
muharrem_eyidogan@hotmail.com
Article navigation
September 2009
Research Papers
Energy Conservation Opportunity in Boiler Systems
Durmus Kaya,
Durmus Kaya
Energy Systems and Environmental Research Institute,
durmus.kaya@mam.gov.tr
TUBITAK-MRC
, P.O. Box 21, 41470 Gebze-Kocaeli, Turkey
Search for other works by this author on:
Muharrem Eyidogan
Muharrem Eyidogan
Department of Mechanical Education,
muharrem_eyidogan@hotmail.com
Kocaeli University
, 41380 Kocaeli, Turkey
Search for other works by this author on:
Durmus Kaya
Energy Systems and Environmental Research Institute,
TUBITAK-MRC
, P.O. Box 21, 41470 Gebze-Kocaeli, Turkeydurmus.kaya@mam.gov.tr
Muharrem Eyidogan
Department of Mechanical Education,
Kocaeli University
, 41380 Kocaeli, Turkeymuharrem_eyidogan@hotmail.com
J. Energy Resour. Technol. Sep 2009, 131(3): 032401 (4 pages)
Published Online: August 4, 2009
Article history
Received:
November 17, 2005
Revised:
May 26, 2009
Published:
August 4, 2009
Citation
Kaya, D., and Eyidogan, M. (August 4, 2009). "Energy Conservation Opportunity in Boiler Systems." ASME. J. Energy Resour. Technol. September 2009; 131(3): 032401. https://doi.org/10.1115/1.3185440
Download citation file:
Get Email Alerts
Cited By
Vacuum-Assisted Multistage Membrane Distillation With Bubble Column Dehumidifier for Efficient Water Production
J. Energy Resour. Technol (February 2023)
Simulation of Flow Field of Solution Mining Salt Cavities for Underground Gas Storage
J. Energy Resour. Technol (February 2023)
Geochemical Modeling of Engineered Water Injection in Carbonates Under Harsh Conditions: New Insights With Ionic Adsorption
J. Energy Resour. Technol (February 2023)
Stratified flames in dual annular counter-rotating swirl burner for wider operability gas turbines
J. Energy Resour. Technol
Related Articles
Experimental Testing of Gerotor and Scroll Expanders Used in, and Energetic and Exergetic Modeling of, an Organic Rankine Cycle
J. Energy Resour. Technol (March,2009)
Revamping, Energy Efficiency, and Exergy Analysis of an Existing Upstream Gas Treatment Facility
J. Energy Resour. Technol (March,2011)
Exergy Analysis of the Annual Operation of a Sugarcane Cogeneration Power Plant Assisted by Linear Fresnel Solar Collectors
J. Sol. Energy Eng (December,2018)
System Study on Partial Gasification Combined Cycle With C O 2 Recovery
J. Eng. Gas Turbines Power (September,2008)
Related Chapters
The Impact of Plant Economics on the Design of Industrial Energy Systems
Industrial Energy Systems
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Section 3. Objectives of Water Treatment
Consensus on Operating Practices for the Control of Feedwater and Boiler Water Chemistry in Industrial and Institutional Boilers