Vehicle heating requires a substantial amount of energy. Electric vehicles (EVs) generate little waste heat, and using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. This paper analyzes the applicability of a desiccant dehumidifier for providing comfort heating in an EV with reduced energy consumption. A dehumidifier can reduce the heating load in a vehicle because it adsorbs the water vapor generated by the passengers, thereby avoiding water condensation on the windows without requiring a high external air ventilation rate or a high window temperature. The results indicate that the desiccant dehumidifier can reduce the steady-state heating load by 60 percent or more under typical conditions. The reduction in heating load is such that waste heat may be enough to provide the required heating under most ambient conditions. Desiccant system dimensions and weight appear reasonable for packaging inside an EV.

1.
Aceves
S. M.
,
1996
, “
An Analytical Comparison of Adsorption and Vapor Compression Air Conditioners for Electric Vehicle Applications
,”
ASME JOURNAL OF ENERGY RESOURCES TECHNOLOGY
, Vol.
118
, pp.
16
21
.
2.
ASHRAE, 1993, ASHRAE Fundamentals Handbook, American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta, GA.
3.
Atkinson, K. E., 1978, An Introduction to Numerical Analysis, John Wiley and Sons, New York, NY.
4.
Automotive News, 1993, “Fuel-Burning Heaters Allowed in California Zero Emission Vehicles,” January 25.
5.
Birch
S.
,
1996
, “
EV1 Follows the Impact
,”
Automotive Engineering
, Vol.
104
, No.
6
, pp.
28
40
.
6.
Burba, J. C., Spiteri, R., and Louch, R., 1995, “Ecostar: A Thermally Managed Vehicle,” Proceedings, Sustainable Transportation ’95 Conference, Northeast Sustainable Energy Association, Paper 4–34.
7.
Charoensupaya
D.
, and
Worek
W. W.
,
1988
, “
Parametric Study of an Open-Cycle Adiabatic, Solid, Desiccant Cooling System
,”
Energy
, Vol.
13
, No.
9
, pp.
739
747
.
8.
Dieckmann, J., and Mallory, D., 1991, “Climate Control for Electric Vehicles,” SAE Paper 910250.
9.
Dieckmann, J., and Mallory, D., 1992, “Variable Speed Compressor, HFC-134a Based Air Conditioning System for Electric Vehicles,” SAE Paper 920444.
10.
Dupont
M.
,
Celestine
B.
,
Nguyen
P. H.
,
Merigoux
J.
, and
Brandon
B.
,
1994
, “
Desiccant Solar Air Conditioning in Tropical Climates: I—Dynamic Experimental and Numerical Studies of Silica Gel and Activated Alumina
,”
Solar Energy
, Vol.
52
, No.
6
, pp.
509
517
.
11.
Feustel
H.
,
de Almeida
A.
, and
Blumstein
C.
,
1992
, “
Alternatives to Compressor Cooling in Residences
,”
Energy and Buildings
, Vol.
18
, pp.
269
286
.
12.
Freedman, M., and Zemke, B., “Cold Weather Update—GM Impact,” Proceedings, Sustainable Transportation ’95 Conference, Northeast Sustainable Energy Association, Paper 4-33.
13.
Haney
S. W.
,
Barr
W. L.
,
Crotinger
J. A.
,
Perkins
L. J.
,
Solomon
C. J.
,
Chaniotakis
E. A.
,
Freidberg
J. P.
,
Wei
J.
,
Galambos
J. D.
, and
Mandrekas
J.
,
1995
, “
A SUPERCODE for System Analysis of Tokamak Experiments and Reactors
,”
Fusion Technology
, Vol.
21
, p.
1749
1749
.
14.
Ikeda, S., Yoshii, Y., and Tamura, Y., 1990, “Air Conditioning Electric Vehicles with an Electronically Driven Variable Speed Scroll Type Compressor,” SAE Paper 901738.
15.
Kays, W. M., and London, A. L., 1964, Compact Heat Exchangers, McGraw-Hill, New York, NY.
16.
Kweller
E.
,
Mei
V. C.
, and
Chen
F. C.
,
1991
, “
Options of Desiccant Cooling and Dehumidification Technology
,”
Proceedings, International Energy Conversion Engineering Conference
, Vol.
2
, pp.
566
570
.
17.
Kyle, D. M., and Sullivan, R. A., 1993, “Heating, Ventilation and Air Conditioning Systems,” US Department of Energy Report, under Contract No. DEAC05-84OR21400.
18.
Mei, V. C., Chen, F. C., Lavan, Z., Collier, R. K., and Meckler, G., 1992, “An Assessment of Desiccant Cooling and Dehumidification Technology,” Oak Ridge National Laboratory Report ORNL/CON-309, Oak Ridge, TN, July.
19.
Nimmo
B. G.
,
Collier
R. K.
, and
Rengarajan
K.
,
1993
, “
DEAC: Desiccant Enhancement of Cooling-Based Dehumidification
,”
ASHRAE Transactions: Symposia
, Vol.
99
, pp.
842
848
.
20.
Roy
D.
, and
Gidaspow
D.
,
1974
, “
Nonlinear Coupled Heat and Mass Exchange in a Cross-Flow Regenerator
,”
Chemical Engineering Science
, Vol.
29
, pp.
2101
2114
.
21.
Shimizu, S., Hara, H., and Asakawa, F., 1982, “Analysis on Air-Conditioning Heat Load of Passenger Vehicle,” JSAE Review, Nov., pp. 80–90.
22.
Suzuki, N., and Takahashi, T., 1995, “Dehumidifying-Type Heat Pump System for Electric Vehicles,” Proceedings, Second Vehicle Thermal Management Systems Meeting, SAE/IMECHE, London, England, pp. 365–369.
23.
Suzuki, T., and Ishii, K., 1996, “Air Conditioning System for Electric Vehicle,” SAE Paper 960688.
24.
Wyczalek
F. A.
,
1993
, “
Heating and Cooling Battery Electric Vehicles-the Final Barrier
,”
Proceedings, International Energy Conversion Engineering Conference
, Vol.
2
, pp.
267
272
.
25.
Zheng
W.
,
Worek
W. M.
, and
Novosel
D.
,
1993
, “
Control and Optimization of Rotational Speeds for Rotary Dehumidifiers
,”
ASHRAE Transactions: Symposia
, Vol.
99
, pp.
825
833
.
This content is only available via PDF.