Generally, porous jump (PJ) model is used for rapid air flow simulations (without resolving the tile pore structure) through perforated floor tiles in data centers. The PJ model only specifies a step pressure loss across the tile surface, without any influence on the flow field. However, in reality, the downstream flow field is affected because of the momentum rise of air due to acceleration through the pores, and interaction of jets emerging from the pores. The momentum rise could be captured by either directly resolving the tile pore structure (geometrical resolution (GR) model) or simulated by specifying a momentum source above the tile surface (modified body force (MBF) model). Note that specification of momentum source obviates the need of resolving the tile pore geometry and, hence, requires considerably low computational effort. In previous investigations, the momentum source was imposed in a region above the tile surface whose width and length were same as the tile dimensions with a preselected height. This model showed improved prediction with the experimental data, as well as with the model resolving the tile pore geometry. In the present investigation, we present an analysis for obtaining the momentum source region dimensions and other associated input variables so that the MBF model can be applied for general cases. The results from this MBF model were compared with the GR model and good agreement was obtained.

References

1.
Joshi
,
Y.
, and
Kumar
,
P.
,
2012
,
Energy Efficient Thermal Management of Data Centers
,
Springer
,
New York
.
2.
Arghode
,
V. K.
, and
Joshi
,
Y.
,
2015
, “
Experimental Investigation of Air Flow Through a Perforated Tile in a Raised Floor Data Center
,”
ASME J. Electron. Packag.
,
137
(
1
), p.
011011
.
3.
Arghode
,
V. K.
,
Kumar
,
P.
,
Joshi
,
Y.
,
Weiss
,
T.
, and
Meyer
,
G.
,
2013
, “
Rack Level Modeling of Air Flow Through Perforated Tile in a Data Center
,”
ASME J. Electron. Packag.
,
135
(
3
), p.
030902
.
4.
Arghode
,
V. K.
, and
Joshi
,
Y.
,
2014
, “
Room Level Modeling of Air Flow in a Contained Data Center Aisle
,”
ASME J. Electron. Packag.
,
136
(
6
), p.
011011
.
5.
Arghode
,
V. K.
,
Sundaralingam
,
V.
,
Joshi
,
Y.
, and
Phelps
,
W.
,
2013
, “
Thermal Characteristics of Open and Contained Data Center Cold Aisle
,”
ASME J. Heat Transfer
,
135
(
6
), p.
061901
.
6.
Abdelmaksoud
,
W. A.
,
Khalifa
,
H. E.
,
Dang
,
T. Q.
,
Elhadidi
,
B.
,
Schmidt
,
R. R.
, and
Iyengar
,
M.
,
2010
, “
Experimental and Computational Study of Perforated Floor Tile in Data Centers
,”
Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems
(
ITherm
), Las Vegas, NV, June 2–5.
7.
Patankar
,
S. V.
,
2010
, “
Airflow and Cooling in a Data Center
,”
ASME J. Heat Transfer
,
132
(
7
), p.
073001
.
8.
Karki
,
K. C.
, and
Patankar
,
S. V.
,
2006
, “
Airflow Distribution Through Perforated Tiles in Raised-Floor Data Centers
,”
Build. Environ.
,
41
(
6
), pp.
734
744
.
9.
Rambo
,
J.
, and
Joshi
,
Y.
,
2007
, “
Modeling of Data Center Airflow and Heat Transfer: State of the Art and Future Trends
,”
Distrib. Parallel Databases
,
21
(
2
), pp.
193
225
.
10.
Alkharabsheh
,
S.
,
Fernandes
,
J.
,
Gebrehiwot
,
B.
,
Agonafer
,
D.
,
Ghose
,
K.
,
Ortega
,
A.
,
Joshi
,
Y.
, and
Sammakia
,
B.
,
2015
, “
A Brief Overview of Recent Developments in Thermal Management in Data Centers
,”
ASME J. Electron. Packag.
,
137
(
4
), p.
040801
.
11.
Alkharabsheh
,
S. A.
,
Sammakia
,
B. G.
, and
Shrivastava
,
S. K.
,
2015
, “
Experimentally Validated Computational Fluid Dynamics Model for a Data Center With Cold Aisle Containment
,”
ASME J. Electron. Packag.
,
137
(
2
), p.
021010
.
12.
Bhagwat
,
H.
,
Singh
,
U.
,
Deodhar
,
A.
,
Singh
,
A.
, and
Sivasubramaniam
,
A.
,
2014
, “
Fast and Accurate Evaluation of Cooling in Data Centers
,”
ASME J. Electron. Packag.
,
137
(
1
), p.
011003
.
13.
Freid
,
E.
, and
Idelchik
,
I. E.
,
1989
,
Flow Resistance, a Design Guide for Engineers
,
Hemisphere
,
New York
.
14.
Miller
,
D. S.
,
1990
,
Internal Flow Systems
, 2nd ed.,
Gulf Publishing
,
Houston, TX
.
15.
Kumar
,
P.
, and
Joshi
,
Y.
,
2010
, “
Experimental Investigations on the Effect of Perforated Tile Air Jet Velocity on Server Air Distribution in a High Density Data Center
,”
Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems
(
ITherm
), Las Vegas, NV, June 2–5.
16.
Arghode
,
V. K.
,
Sundaralingam
,
V.
, and
Joshi
,
Y.
,
2016
, “
Air Flow Management in a Contained Cold Aisle Using Active Fan Tiles for Energy Efficient Data Center Operation
,”
Heat Transfer Eng.
,
37
(
3
), pp.
246
256
.
17.
Lipari
,
G.
, and
Stansby
,
P. K.
,
2011
, “
Review of Experimental Data on Incompressible Turbulent Round Jets
,”
Flow, Turbul. Combust.
,
87
(
1
), pp.
79
114
.
18.
Arghode
,
V. K.
, and
Joshi
,
Y.
,
2013
, “
Modeling Strategies for Air Flow Through Perforated Tiles in a Data Center
,”
IEEE Trans. Compon., Packag., Manuf. Technol.
,
3
(
5
), pp.
800
810
.
19.
Yimer
,
I.
,
Becker
,
H. A.
, and
Grandmaison
,
E. W.
,
1996
, “
Development of Flow From Multiple–Jet Burners
,”
Can. J. Chem. Eng.
,
74
(
6
), pp.
84
851
.
20.
Arghode
,
V. K.
, and
Joshi
,
Y.
,
2015
, “
Evaluation of Modified Body Force (MBF) Model for Rapid Air Flow Modeling Through Perforated Tiles
,”
Semiconductor Thermal Measurement and Management Symposium
(
SEMI-THERM
), San Jose, CA, Mar. 15–19, pp. 127–137.
You do not currently have access to this content.