Skip to Main Content
ASME Press Select Proceedings

International Conference on Electronics, Information and Communication Engineering (EICE 2012)

By
Garry Lee
Garry Lee
Information Engineering Research Institute
Search for other works by this author on:
ISBN:
9780791859971
No. of Pages:
1008
Publisher:
ASME Press
Publication date:
2012

A finite element model of an eddy current sensor array is built up by electromagnetic-circuit couple method, and the influences of copper foil thickness on sensor's output characteristics are analyzed by the model. It was shown that the amplitudes of sensing coils' output would increase, while the phases would decrease gradually when foil thickness increased. Besides, the discrepancies of phase were diminished when the foil becoming thicker. While the differences of amplitude increased and reached the maximum at thickness of 0.67, then it began to decrease. Generally it is necessary to make the copper foil thickness between 0.17 and 0.33 in sensor fabrication process to enhance the crack inspecting capability of the sensor.