Thermocouples are one of the most popular devices for temperature measurement due to their robustness, ease of manufacture and installation, and low cost. However, when used in the harsh environment found in combustion systems and automotive engine exhausts, large wire diameters are required and consequently the measurement bandwidth is reduced. This paper describes two new algorithmic compensation techniques based on blind deconvolution to address this loss of high-frequency signal components using the measurements from two thermocouples. In particular, a continuous-time approach is proposed, combined with a cross-relation blind deconvolution for parameter estimation. A feature of this approach is that no a priori assumption is made about the time constant ratio of the two thermocouples. The advantages, including small estimation variance and limitations of the method, are highlighted using results from simulation and test rig studies.
Skip Nav Destination
e-mail: s.mcloone@ieee.org
Article navigation
March 2007
Technical Papers
Blind Deconvolution for Two-Thermocouple Sensor Characterization
Peter C. Hung,
Peter C. Hung
Virtual Engineering Centre,
Queen’s University Belfast
, Belfast BT9 5HN, Northern Ireland
Search for other works by this author on:
Robert J. Kee,
Robert J. Kee
Virtual Engineering Centre,
Queen’s University Belfast
, Belfast BT9 5HN, Northern Ireland
Search for other works by this author on:
George W. Irwin,
George W. Irwin
Virtual Engineering Centre,
Queen’s University Belfast
, Belfast BT9 5HN, Northern Ireland
Search for other works by this author on:
Seán F. McLoone
Seán F. McLoone
Department of Electronic Engineering,
e-mail: s.mcloone@ieee.org
National University of Ireland, Maynooth
, Maynooth, Co. Kildare, Ireland
Search for other works by this author on:
Peter C. Hung
Virtual Engineering Centre,
Queen’s University Belfast
, Belfast BT9 5HN, Northern Ireland
Robert J. Kee
Virtual Engineering Centre,
Queen’s University Belfast
, Belfast BT9 5HN, Northern Ireland
George W. Irwin
Virtual Engineering Centre,
Queen’s University Belfast
, Belfast BT9 5HN, Northern Ireland
Seán F. McLoone
Department of Electronic Engineering,
National University of Ireland, Maynooth
, Maynooth, Co. Kildare, Irelande-mail: s.mcloone@ieee.org
J. Dyn. Sys., Meas., Control. Mar 2007, 129(2): 194-202 (9 pages)
Published Online: June 10, 2006
Article history
Received:
January 5, 2006
Revised:
June 10, 2006
Citation
Hung, P. C., Kee, R. J., Irwin, G. W., and McLoone, S. F. (June 10, 2006). "Blind Deconvolution for Two-Thermocouple Sensor Characterization." ASME. J. Dyn. Sys., Meas., Control. March 2007; 129(2): 194–202. https://doi.org/10.1115/1.2431814
Download citation file:
Get Email Alerts
Cited By
Offline and online exergy-based strategies for hybrid electric vehicles
J. Dyn. Sys., Meas., Control
Optimal Control of a Roll-to-Roll Dry Transfer Process With Bounded Dynamics Convexification
J. Dyn. Sys., Meas., Control (May 2025)
In-Situ Calibration of Six-Axis Force/Torque Transducers on a Six-Legged Robot
J. Dyn. Sys., Meas., Control (May 2025)
Active Data-enabled Robot Learning of Elastic Workpiece Interactions
J. Dyn. Sys., Meas., Control
Related Articles
Identification of Time-Varying Time Constants of Thermocouple Sensors and Its Application to Temperature Measurement
J. Dyn. Sys., Meas., Control (January,2009)
Design of Micro-Temperature Sensor Array With Thin Film Thermocouples
J. Electron. Packag (September,2005)
Development of Ni Cr ∕ Ni Si Thin-Film Thermocouple Sensor for Workpiece Temperature Measurement in Chemical Explosive Material Machining
J. Manuf. Sci. Eng (February,2006)
A Dual-Scale Computational Method for Correcting Surface Temperature
Measurement Errors
J. Heat Transfer (August,2004)
Related Chapters
Suggestions Towards Improved Reliability of Thermocouple Temperature Measurement in Combustion Tests
Thermal Measurements: The Foundation of Fire Standards
Thermocouples: The Simplest Way to Measure Temperature Wrong
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong
Thermotriples
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong