Abstract

As building, energy, and green codes become more stringent, new building technologies and innovations are being incorporated into the building envelope. When incorporating new technologies into building assemblies, traditional construction practices need to be adapted. However, as these adaptations of construction practices take place, they still need to maintain adherence to basic principles of water management to prevent moisture accumulation in building assemblies. A critical component of water management is water-resistive barriers. Water-resistive barriers are used in light-frame wall assemblies behind the cladding to control the ingress of water, which penetrates the cladding, and keep it from penetrating further into the wall. Traditional water-resistive barriers were asphalt-impregnated papers and felts, which were applied in shingle fashion over the wall studs or sheathing. Plastic building wraps have to a large extent replaced the traditional building papers, comprising 75 % of the U.S. housing market. Recently, new materials being used as water-resistive barriers include panel materials and fluid-applied coatings. Assessing the durability of water-resistive barriers has been complicated by this range of material types. Because of the shingle-fashion installation, durability assessment of traditional materials and building wraps has focused on the material durability. The new materials require additional durability assessments relating to compatibility and durability of adhesion, most importantly at panel and substrate joints. This article describes the framework for evaluating water-resistive barrier durability.

References

1.
CSA S478-95
Guideline on Durability in Buildings
,
Standards Council of Canada
,
Ottawa, Canada
,
2001
, www.scc.ca
2.
ICC
2015 International Building Code
,
International Code Council, Inc.
,
Country Club Hills, IL
,
2014
, 700p.
3.
ASTM D226-09
Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
(Superseded),
ASTM International
,
West Conshohocken, PA
,
2009
, www.astm.org
4.
UU-B-790A
Federal Specification: Building Paper, Vegetable Fiber: (Kraft, Waterproofed, Water Repellent and Fire Resistant)
,
Naval Facilities Engineering Command
,
Washington, DC
,
1968
, www.everyspec.com
5.
ASTM E2556-10
Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment
,
ASTM International
,
West Conshohocken, PA
,
2010
, www.astm.org
6.
ICC
2015 International Residential Code
,
International Code Council, Inc.
,
Country Club Hills, IL
,
2014
, 902p.
7.
ICC-ES AC38
Water-Resistive Barriers
,
International Code Council
,
Washington, DC
,
2015
, www.global.ihs.com
8.
ASTM G154-16
Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials
,
ASTM International
,
West Conshohocken, PA
,
2016
, www.astm.org
9.
ASTM E1677-11
Standard Specification for Air Barrier (AB) Material or System for Low-Rise Framed Building Walls
,
ASTM International
,
West Conshohocken, PA
,
2011
, www.astm.org
10.
ASTM E2357-11
Standard Test Method for Determining Air Leakage of Air Barrier Assemblies
(Superseded),
ASTM International
,
West Conshohocken, PA
,
2011
, www.astm.org
11.
AAMA 711-13
Voluntary Specification for Self-Adhering Flashing Used for Installation of Exterior Wall Fenestration Products
,
American Architectural Manufacturers Association
,
Schaumburg, IL
,
2013
, www.aamanet.org
12.
ASTM G155-13
Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
,
ASTM International
,
West Conshohocken, PA
,
2013
, www.astm.org
13.
ICC-ES AC212
Water-Resistive Coatings Used as Water-Resistive Barriers over Exterior Sheathing
,
International Code Council
,
Washington, DC
,
2011
, www.global.ihs.com
14.
ASTM D2247-15
Standard Practice for Testing Water Resistance of Coatings in 100 % Relative Humidity
,
ASTM International
,
West Conshohocken, PA
,
2015
, www.astm.org
15.
Wissink
,
K. S.
,
Bashaw
,
L. K.
, and
Nelson
,
P. E.
, “
Applicability of Fluid-Applied Air and Water-Resistive Barriers in Exterior Insulation and Finish Systems for Use in Other Cladding Systems
,” Exterior Insulation and Finish Systems (EIFS): Performance, Progress and Innovation,
ASTM STP1585
,
Nelson
P. E.
and
Egan
B.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
2016
, pp. 
265
287
, https://doi.org/10.1520/STP158520140112
16.
ICC-ES AC71
Foam Plastic Sheathing Panels Used as Water-Resistive Barriers
,
International Code Council
,
Washington, DC
,
2011
, www.global.ihs.com
17.
ICC-ES AC310
Water-Resistive Membranes Factory-Bonded to Wood-Based Structural Sheathing, Used as Water-Resistive Barriers
,
International Code Council
,
Washington, DC
,
2012
, www.global.ihs.com
18.
ICC-ES AC382
Laminated Fibrous Board Sheathing Material Used as a Water-Resistive Barrier
,
International Code Council
,
Washington, DC
,
2012
, www.global.ihs.com
19.
Weston
,
T. A.
,
Pascual
,
X.
, and
Boone
,
K.
, “
Water Resistance and Durability of Weather-Resistive Barriers
,” Performance and Durability of the Window-Wall Interface,
ASTM STP1484
,
Hardman
B. G.
,
Wagus
C. R.
, and
Weston
T. A.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
2006
, pp. 
3
18
, https://doi.org/10.1520/STP37708S
20.
Wissink
,
K. S.
,
Bashaw
,
L. K.
, and
Ruggiero
,
S. S.
, “
Comparative Analysis of Fluid-Applied Air Barrier Products
,” Building Walls Subject to Water Intrusion and Accumulation: Lessons from the Past and Recommendations for the Future,
ASTM STP1549
,
Erdly
J.
and
Johnson
P.
, Eds.,
ASTM International
,
West Conshohocken, PA
,
2014
, pp. 
187
201
, https://doi.org/10.1520/STP154920130054
21.
Steven Winter Associates, Inc.,
Energy Efficient and Green Technology Building Template Guide for the State of Maryland
,
Maryland Energy Administration
,
Baltimore, MD
,
2007
, 63p.
22.
Wolters Kluwer Editorial Staff “
Planning for Foam Shrinkage
,”
Energy Design Update
, Vol. 
26
, No. 
9
,
2006
.
23.
Baker
,
P.
, “
Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure
,” presented at the
ACEEE Summer Study on Energy Efficiency in Buildings
, Pacific Grove, CA, Aug. 13–18,
2006
,
American Council for an Energy-Efficient Economy
,
Washington, DC
, 12p.
24.
Air Barrier Update–Technology Brief
,” International Masonry Institute, Annapolis, MD, January
2004
, www.imiweb.org
25.
ASTM E331-00(2016)
Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
,
ASTM International
,
West Conshohocken, PA
,
2016
, www.astm.org
26.
ASTM E283-04(2012)
Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
,
ASTM International
,
West Conshohocken, PA
,
2012
, www.astm.org
27.
ASTM E330/E330M-14
Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
,
ASTM International
,
West Conshohocken, PA
,
2014
, www.astm.org
This content is only available via PDF.
You do not currently have access to this content.