Abstract

The use of different forming materials, insulating materials, and stripping times can significantly affect the maturity and hence the strength gain of concrete within forming systems. This information can be vital in determining the stripping time of scaffolding and formwork. In this project, maturity and compression tests were performed on specimens (simulating scaled-down walls) formed using a polyvinyl chloride stay-in-place (SIP) forming system with and without insulation. The findings were then compared to data obtained from walls formed by wood formwork, which is the material typically used in the field. The various parameters studied in this project were wall thickness, type of forming material, insulation, and addition of fly ash. The results indicate that with an increase in wall thickness, the peak temperature and the temperature development index (TDI) increased proportionally. TDI is defined as the area under the temperature-versus-time curve measured from the dormant temperature to the peak temperature. The data show that the proposed TDI was a good indicator of the extent of the hydration reaction, and with further research the relationship between temperature development and strength gain of concrete could be clearly identified. Increases in the peak temperature and TDI were noted in wood forming systems relative to SIP systems and in insulated systems relative to un-insulated systems. The use of fly ash in concrete resulted in a lower temperature peak and TDI and a delay in reaching peak temperature. However, the use of concrete containing fly ash in insulated SIP systems led to a higher TDI than a conventional concrete mix formed in wood forms, indicating better concrete maturity at the same age.

References

1.
Kuder
,
K.G.
,
Gupta
,
R.
,
Sodders
,
C.
,
Hawksworth
,
R.
,
Henderson
,
S.
, and
Whitney
,
J.
, “
Effect of PVC Stay-in-Place Formwork on Mechanical Performance of Concrete
,”
J. Mater. Civ. Eng.
, Vol.
21
, No.
7
,
2009
, pp.
309
315
. https://doi.org/10.1061/(ASCE)0899-1561(2009)21:7(309)
2.
Octaform Systems Inc.
, “
Technical Guide
,”http://www.octaform.com/index.php?page=technical-guides (Last accessed 1 Oct
2009
).
3.
Mindess
,
S.
,
Young
,
F.J.
, and
Darwin
,
D.
,
Concrete
,
Prentice-Hall
,
Upper Saddle River, NJ
,
2003
.
4.
Malhotra
,
M.
, “
Reducing CO2 Emissions: The Role of Fly Ash and Other Supplementary Cementitious Materials
,”
Concrete Int.
, Vol.
28
, No.
9
,
2006
, pp.
42
45
.
5.
Mehta
,
P.K.
, “
Global Concrete Industry Sustainability: Tools for Moving Forward to Cut Carbon Emissions
,”
Concrete Int.
, Vol.
31
, No.
2
,
2009
, pp.
45
48
.
6.
Khan
,
A.A.
,
Cook
,
W.D.
, and
Mitchell
,
D.
, “
Thermal Properties and Transient Thermal Analysis of Structural Members During Hydration
,”
ACI Mater. J.
, Vol.
95
, No.
3
,
1998
, pp.
293
303
.
7.
Wang
,
K.
,
Zhi
,
G.
,
Grove
,
J.
,
Ruiz
,
J.M.
,
Rasmussen
,
R.
, and
Ferragut
,
T.
,
Developing a Simple and Rapid Test for Monitoring the Heat Evolution of Concrete Mixtures for Both Laboratory and Field Applications
,
N.C.P.T. Center
,
Iowa
,
2006
.
8.
ASTM C192/C192M
:
Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory
,
Annual Book of ASTM Standards
,
ASTM International
,
West Conshohocken, PA
,
2012
.
9.
ASTM C31/C31M
:
Standard Practice for Making and Curing Concrete Test Specimens in the Field
,
Annual Book of ASTM Standards
,
ASTM International
,
West Conshohocken, PA
,
2012
.
10.
Lowrie
,
K.
,
Sommer
,
D.
, and
Wheeler
,
N.
,
Effect of PVC Stay-in-Place Formwork on the Hydration of Concrete
,
Seattle University
,
Seattle, WA
,
2007
.
11.
TECO
, “
Panel R Values
,” http://www.tecotested.com/prod-info (Last accessed 15 June
2010
).
This content is only available via PDF.