Abstract

The aim of this research is to evaluate how transport properties at the surface and in the core of high-performance concrete (HPC) slabs are affected by silica fume and by superplasticizer and retarding agent dosages. The transport properties were evaluated by measuring the air permeability at two depths under the surface finished with a wooden trowel. The experimental program is based on eight different high-performance concrete mixtures (77 to 93 MPa) made with a water-to-binder ratio of 0.30. An ordinary portland cement (OPC) and a blended silica-fume cement (SF) were used to compare the effect of silica fume on the air permeability of surface and core concrete. Four mixtures were produced with a retarding agent to assess the effect of set retardation on the surface properties of high-performance concrete. For each combination of cement type and retarding agent dosages, the superplasticizer dosage was selected to produce two slump levels of 100 ± 10 mm and 200 ± 20 mm.

It was found that the air permeability of the concrete located just beneath the surface of HPC slabs can be 2 to 20 times higher than the core permeability. The ratio between the surface and core permeabilities depends on mix-design parameters such as silica fume, superplasticizer (slump), and retarding agent dosages. Increasing the slump of HPC (from 100 to 200 mm) systematically increased the surface permeability. The effect of slump (or superplasticizer dosage) on the surface permeability of the HPC decreased as compressive strength increased. The use of a retarding agent in HPC without silica fume increased the air permeability of the surface concrete. This effect is particularly important for the concrete containing a high dosage of superplasticizer. Silica fume proved very effective in inhibiting increased surface permeability due to the dosages of superplasticizers and retarding agents.

References

1.
De Larrard
,
F.
and
Bostvironnois
,
J. L.
,
1991
, “
On the Long Term Strength Losses of Silica-Fume High-Strength Concretes
,”
Magazine of Concrete Research
, Vol.
43
, No.
155
, pp.
109
119
.
2.
Gagné
,
R.
,
Boisvert
,
A.
, and
Pigeon
,
M.
,
1995
, “
Effect of Superplasticizer on Mechanical Properties, Permeability and Freeze-Thaw Durability of High-Strength Concretes With and Without Silica Fume
,”
ACI Materials Journal
 0889-325X, Vol.
93
, No.
2
, pp.
111
120
.
3.
Hooton
,
R. D.
and
McGrath
,
P.
,
1991
, “
Influence of Self-Desiccation of Non-Air Entrained Silica Fume Mortars on Resistance to Freezing and Thawing
,”
CANMET/ACI International Workshop on the Use of Silica Fume in Concrete
,
Washington, DC
, pp.
243
254
.
4.
Hua
,
C.
,
Acker
,
P.
, and
Ehrlacher
,
A.
,
1995
, “
Retrait d'autodessiccation du ciment—Analyse et modélisation macroscopique
,”
Bulletin de Liaison du Laboratoire des Ponts et Chaussées
, Vol.
196
, March–April, pp.
79
89
.
5.
Kreijger
,
P. C.
,
1984
, “
The Skin of Concrete: Composition and Properties
,”
Materials and Structures
 1359-5997, Vol.
17
, No.
100
, pp.
275
283
.
6.
Parrott
L. J.
,
1992
, “
Variation of Water Absorption Rate and Porosity with Depth from an Exposed Concrete Surface: Effect of Exposure Conditions and Cement Type
,”
Cement and Concrete Research
 0008-8846, Vol.
22
, No.
6
, pp.
1077
1088
.
7.
Rollet
,
M.
,
Levy
,
C.
, and
Chabanis
,
F.
,
1992
, “
Physical, Mechanical and Durability Characteristics of Various Compressive Strength Concretes (from 20 to 120 MPa)
,”
Proceedings of the CANMET/ACI International Conference on Advances in Concrete Technology
,
Athens, Greece
, pp.
207
225
.
8.
Sellevold
,
E. J.
,
Justness
,
H.
,
Smeplass
,
S.
, and
Hansen
,
E. A.
,
1994
, “
Selected Properties of High Performance Concrete
,” Invited paper,
Advances in Cement and Concrete, Proceedings of the American Society of Civil Engineers
,
New York
, 41 pp.
9.
Torrent
,
R. J.
and
Jornet
,
A.
,
1991
, “
The Quality of the “Coverconcrete” of Low-, Medium- and High-Strength Concrete
,”
Durability of Concrete
, ACI SP-126, pp.
1147
1161
.
10.
Yssorche
,
M. P.
,
1995
, “
Microfissuration et Durabilité des Bétons à Hautes Performances
,” Doctoral thesis, In French,
Laboratoire Matériaux et Durabilité des Constructions, Institut National des Sciences Appliquées, Département de Génie Civil
, Toulouse, France, 181 pp.
11.
Yssorche
,
M. P.
,
Bigas
,
J. P.
, and
Ollivier
,
J. P.
,
1995
, “
Mesure de la Perméabilité à L'air des Bétons au Moyen d'un Perméamètre à Charge Variable
,”
Materials and Structures
 1359-5997, Vol.
28
, pp.
401
405
.
This content is only available via PDF.
You do not currently have access to this content.