Skip Nav Destination
Issues
November 1988
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Research Papers
A Combined Macro and Microvascular Model for Whole Limb Heat Transfer
J Biomech Eng. November 1988, 110(4): 259–268.
doi: https://doi.org/10.1115/1.3108440
Topics:
Heat transfer
,
Muscle
,
Skin
,
Temperature
,
Biological tissues
,
Blood
,
Blood flow
,
Boundary-value problems
,
Engineering prototypes
,
Heat
Thermal Modeling of the Malignant Woman’s Breast
J Biomech Eng. November 1988, 110(4): 269–276.
doi: https://doi.org/10.1115/1.3108441
Topics:
Blood
,
Heat
,
Modeling
,
Three-dimensional models
,
Tumors
Heat Transfer Normal to Paired Arterioles and Venules Embedded in Perfused Tissue During Hyperthermia
J Biomech Eng. November 1988, 110(4): 277–282.
doi: https://doi.org/10.1115/1.3108442
Topics:
Biological tissues
,
Heat transfer
,
Temperature
,
Vessels
,
Cylinders
,
Steady state
,
Transients (Dynamics)
,
Blood
,
Blood vessels
,
Computer simulation
Convection-Diffusion Interaction for Oscillatory Flow in a Tapered Tube
J Biomech Eng. November 1988, 110(4): 283–291.
doi: https://doi.org/10.1115/1.3108443
Topics:
Convection
,
Diffusion (Physics)
,
Flow (Dynamics)
,
Cycles
,
Equations of motion
Numerical Solutions for Steady and Unsteady Flow in a Model of the Pulmonary Airways
J Biomech Eng. November 1988, 110(4): 292–299.
doi: https://doi.org/10.1115/1.3108444
Topics:
Unsteady flow
,
Flow (Dynamics)
,
Pressure
,
Stiffness
,
Computation
,
Viscous flow
,
Waves
Flow Measurements in a Human Femoral Artery Model With Reverse Lumen Curvature
J Biomech Eng. November 1988, 110(4): 300–309.
doi: https://doi.org/10.1115/1.3108446
Flow Measurements in an Atherosclerotic Curved, Tapered Femoral Artery Model of Man
J Biomech Eng. November 1988, 110(4): 310–319.
doi: https://doi.org/10.1115/1.3108447
Shear-Layer Detection in Poststenotic Flow by Spectrum Analysis of Doppler Signals
J Biomech Eng. November 1988, 110(4): 320–325.
doi: https://doi.org/10.1115/1.3108448
Topics:
Emission spectroscopy
,
Flow (Dynamics)
,
Shear (Mechanics)
,
Signals
,
Spectroscopy
,
Spectra (Spectroscopy)
,
Doppler effect
,
Density
,
Reynolds number
,
Waves
Hot-Film Wall Shear Probe Measurements Inside a Ventricular Assist Device
J Biomech Eng. November 1988, 110(4): 326–333.
doi: https://doi.org/10.1115/1.3108449
Topics:
Probes
,
Shear (Mechanics)
,
Ventricular assist devices
,
Shear stress
,
Valves
,
Artificial limbs
,
Flow (Dynamics)
,
Calibration
,
Inflow
,
Outflow
Model Studies at Mechanical Aortic Heart Valve Prostheses—Part I: Steady-State Flow Fields and Pressure Loss Coefficients
J Biomech Eng. November 1988, 110(4): 334–343.
doi: https://doi.org/10.1115/1.3108450
Topics:
Flow (Dynamics)
,
Heart valve prostheses
,
Pressure
,
Steady state
,
Flow separation
,
Turbulence
,
Aorta
,
Biomedicine
,
Blood
,
Damage
Finite Elasticity Modeling of the Biaxial and Uniaxial Properties of Compliant Vascular Grafts
J Biomech Eng. November 1988, 110(4): 344–348.
doi: https://doi.org/10.1115/1.3108451
Topics:
Elasticity
,
Modeling
,
Stress
,
Young's modulus
,
Pressure
,
Strips
Biaxial Mechanical Behavior of Excised Epicardium
J Biomech Eng. November 1988, 110(4): 349–351.
doi: https://doi.org/10.1115/1.3108452
Topics:
Mechanical behavior
Relationship Between Mechanical Properties and Collagen Structure of Closed and Open Wounds
J Biomech Eng. November 1988, 110(4): 352–356.
doi: https://doi.org/10.1115/1.3108453
Topics:
Mechanical properties
,
Wounds
,
Fibers
,
Tensile strength
,
Delays
,
Skin
The Micromechanics Versus the Macromechanics of Cortical Bone—A Comprehensive Presentation
J Biomech Eng. November 1988, 110(4): 357–363.
doi: https://doi.org/10.1115/1.3108454
Topics:
Bone
,
Micromechanics (Engineering)
,
Fibers
,
Biomechanics
,
Compression
,
Mechanical properties
,
Tension
The Three-Dimensional Kinematics and Flexibility Characteristics of the Human Ankle and Subtalar Joints—Part I: Kinematics
J Biomech Eng. November 1988, 110(4): 364–373.
doi: https://doi.org/10.1115/1.3108455
Topics:
Kinematics
,
Rotation
,
Bone
,
Data acquisition systems
,
Hinges
,
Kinematic analysis
The Three-Dimensional Kinematics and Flexibility Characteristics of the Human Ankle and Subtalar Joint—Part II: Flexibility Characteristics
J Biomech Eng. November 1988, 110(4): 374–385.
doi: https://doi.org/10.1115/1.3108456
Topics:
Databases
,
Displacement
,
Kinematics
,
Knee
,
Rupture
,
Stress
,
Wounds
Analytical Description of Minimum Energy Expenditure Surfaces
J Biomech Eng. November 1988, 110(4): 386–391.
doi: https://doi.org/10.1115/1.3108457
Errata
Technical Briefs
Continuous Monitoring of Erythrocyte Sedimentation Process: A New Possible Mechanism of Erythrocyte Sedimentation
J Biomech Eng. November 1988, 110(4): 392–395.
doi: https://doi.org/10.1115/1.3108458
Topics:
Erythrocytes
,
Sedimentation
,
Fracture (Process)
,
Junctions
,
Light sources
,
Plasmas (Ionized gases)