Abstract

Sensorized insoles (SIs) have been used as a wearable instrument to study human gait and have the potential to identify and predict pathologies and injuries. However, most of these sensorized insoles are only statically calibrated, relying on a scale and known weights to establish a relationship between electrical signals and the load applied on laboratory benches while ignoring the dynamic interaction between person and instrument. This study proposes and verifies a calibration method complementary to static calibration to compensate for different dynamic interactions between the insole and the individual during gait. In order to perform this comparison, a laboratory test was proposed with 32 volunteers (18 men and 14 women). Each volunteer walked on a double-belt instrumented treadmill (Bertec at 1000 Hz, Bertec Corp, Columbus, OH) while wearing an experimental resistive sensorized insole (SI). The SI data were compared with the instrumented treadmill and adjusted using an optimization algorithm to create a dynamic coefficient to complement and optimize the results. This study also verifies the impact of the method considering three different types of gait: pronated, neutral, and supinated. After using this technique and considering static calibration, the Pearson correlation coefficient between the SI and the instrumented treadmill improved by 12%.

References

1.
Perry
,
J.
,
Araújo
,
A. G. N.
,
de Freitas
,
C. D.
, and
Schoneberger
,
B.
,
2005
, “
Análise de Marcha
,”
Marcha: Sistemas de Análise de Marcha
,
Manole
,
Barueri, Brazil
, pp.
58
61
.
2.
Robertson
,
G.
,
Caldwell
,
G.
,
Hamill
,
J.
,
Kamen
,
G.
, and
Whittlesey
,
S.
,
2013
,
Research Methods in Biomechanics
,
Human Kinetics
,
Champaign, IL
.
3.
Osoba
,
M. Y.
,
Rao
,
A. K.
,
Agrawal
,
S. K.
, and
Lalwani
,
A. K.
,
2019
, “
Balance and Gait in the Elderly: A Contemporary Review
,”
Laryngoscope Invest. Otolaryngol.
,
4
(
1
), pp.
143
153
.10.1002/lio2.252
4.
Vimieiro
,
C.
,
Andrada
,
E.
,
Witte
,
H.
, and
Pinotti
,
M.
,
2015
, “
A Computational Model for Dynamic Analysis of the Human Gait
,”
Comput. Methods Biomech. Biomed. Eng.
,
18
(
7
), pp.
799
804
.10.1080/10255842.2013.848859
5.
Tan
,
A. M.
,
Fuss
,
F. K.
,
Weizman
,
Y.
, and
Troynikov
,
O.
,
2015
, “
Development of a Smart Insole for Medical and Sports Purposes
,”
Procedia Eng.
,
112
, pp.
152
156
.10.1016/j.proeng.2015.07.191
6.
Tahir
,
A. M.
,
Chowdhury
,
M. E.
,
Khandakar
,
A.
,
Al-Hamouz
,
S.
,
Abdalla
,
M.
,
Awadallah
,
S.
,
Reaz
,
M. B. I.
, et al.,
2020
, “
A Systematic Approach to the Design and Characterization of a Smart Insole for Detecting Vertical Ground Reaction Force (vGRF) in Gait Analysis
,”
Sensors
,
20
(
4
), p.
957
.10.3390/s20040957
7.
Ivanov
,
K.
,
Mei
,
Z.
,
Lubich
,
L.
,
Guo
,
N.
,
Xile
,
D.
,
Zhao
,
Z.
, and
Omisore
,
O. M.
, et al.,
2019
, “
Design of a Sensor Insole for Gait Analysis
,”
International Conference on Intelligent Robotics and Applications
,
Springer
,
Cham
, Aug. 8–11, pp.
433
444
.10.1007/978-3-030-27538-9_37
8.
Malvade
,
P. S.
,
Joshi
,
A. K.
, and
Madhe
,
S. P.
,
2017
, “
In-Sole Shoe Foot Pressure Monitoring for Gait Analysis
,” 2017 International Conference on Computing, Communication, Control and Automation (
ICCUBEA
),
IEEE
,
Pune, India
, Aug. 17–18, pp.
1
4
.10.1109/ICCUBEA.2017.8463769
9.
Martini
,
E.
,
Fiumalbi
,
T.
,
Dell'Agnello
,
F.
,
Ivanić
,
Z.
,
Munih
,
M.
,
Vitiello
,
N.
, and
Crea
,
S.
,
2020
, “
Pressure-Sensitive Insoles for Real-Time Gait-Related Applications
,”
Sensors
,
20
(
5
), p.
1448
.10.3390/s20051448
10.
Eguchi
,
R.
,
Yorozu
,
A.
,
Fukumoto
,
T.
, and
Takahashi
,
M.
,
2016
, “
Ground Reaction Force Estimation Using Insole Plantar Pressure Measurement System From Single-Leg Standing
,” 2016 IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (
MFI
),
IEEE
,
Baden-Baden, Germany
, Sept. 19–21, pp.
109
113
.10.1109/MFI.2016.7849475
11.
Fuchs
,
P. X.
,
Hsieh
,
C.-H.
,
Chen
,
W.-H.
,
Tang
,
Y.-S.
,
Fiolo
,
N. J.
, and
Shiang
,
T.-Y.
,
2022
, “
Sensor Number in Simplified Insole Layouts and the Validity of Ground Reaction Forces During Locomotion
,”
Sports Biomech.
, pp.
1
14
.10.1080/14763141.2022.2057354
12.
Chuckpaiwong
,
B.
,
Nunley
,
J. A.
,
Mall
,
N. A.
, and
Queen
,
R. M.
,
2008
, “
The Effect of Foot Type on in-Shoe Plantar Pressure During Walking and Running
,”
Gait Posture
,
28
(
3
), pp.
405
411
.10.1016/j.gaitpost.2008.01.012
13.
PhysioCode
,
2022
, Physiocode Company, Minas Gerais, accessed Aug. 12, 2022, https://www.physiocode.com.br
14.
Reiff
,
A.
,
2016
, “
Different In-Shoe Devices For Partial Weight Bearing”. Ph.D. thesis
,”
Faculty of Science and Engineering
,
Groningen, The Netherlands
.
15.
Crea
,
S.
,
Donati
,
M.
,
De Rossi
,
S. M. M.
,
Oddo
,
C. M.
, and
Vitiello
,
N.
,
2014
, “
A Wireless Flexible Sensorized Insole for Gait Analysis
,”
Sensors
,
14
(
1
), pp.
1073
1093
.10.3390/s140101073
16.
Dyer
,
P. S.
, and
Bamberg
,
S. J. M.
,
2011
, “
Instrumented Insole vs. Force Plate: A Comparison of Center of Plantar Pressure
,”
2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
,
IEEE
,
Boston, MA
, Aug. 30–Sept. 3, pp.
6805
6809
.10.1109/IEMBS.2011.6091678
17.
Kanitthika
,
K.
, and
Chan
,
K. S.
,
2014
, “
Pressure Sensor Positions on Insole Used for Walking Analysis
,”
The 18th IEEE International Symposium on Consumer Electronics
(
ISCE 2014
),
IEEE
,
Jeju, Korea
, June 22–25, pp.
1
2
.10.1109/ISCE.2014.6884394
18.
Ferrari
,
A.
,
Cutti
,
A. G.
, and
Cappello
,
A.
,
2010
, “
A New Formulation of the Coefficient of Multiple Correlation to Assess the Similarity of Waveforms Measured Synchronously by Different Motion Analysis Protocols
,”
Gait Posture
,
31
(
4
), pp.
540
542
.10.1016/j.gaitpost.2010.02.009
19.
Al-Amri
,
M.
,
Nicholas
,
K.
,
Button
,
K.
,
Sparkes
,
V.
,
Sheeran
,
L.
, and
Davies
,
J. L.
,
2018
, “
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
,”
Sensors
,
18
(
3
), p.
719
.10.3390/s18030719
20.
Sorrentino
,
I.
,
Andrade Chavez
,
F. J.
,
Latella
,
C.
,
Fiorio
,
L.
,
Traversaro
,
S.
,
Rapetti
,
L.
,
Tirupachuri
,
Y.
, et al.,
2020
, “
A Novel Sensorised Insole for Sensing Feet Pressure Distributions
,”
Sensors
,
20
(
3
), p.
747
.10.3390/s20030747
21.
Kang
,
H.
,
2021
, “
Sample Size Determination and Power Analysis Using the G*Power Software
,”
J. Educ. Eval. Health Prof.
,
18
, p.
17
.10.3352/jeehp.2021.18.17
22.
Selman
,
B.
, and
Gomes
,
C. P.
,
2006
, “
Hill-Climbing Search
,”
Encyclopedia Cognitive Sci, John Wiley & Sons, Ltd, Hoboken, NJ.
23.
Queen
,
R. M.
,
Mall
,
N. A.
,
Nunley
,
J. A.
, and
Chuckpaiwong
,
B.
,
2009
, “
Differences in Plantar Loading Between Flat and Normal Feet During Different Athletic Tasks
,”
Gait Posture
,
29
(
4
), pp.
582
586
.10.1016/j.gaitpost.2008.12.010
24.
Barratt
,
G. K.
,
Bellenger
,
C.
,
Robertson
,
E. Y.
,
Lane
,
J.
, and
Crowther
,
R. G.
,
2021
, “
Validation of Plantar Pressure and Reaction Force Measured by Moticon Pressure Sensor Insoles on a concept2 Rowing Ergometer
,”
Sensors
,
21
(
7
), p.
2418
.10.3390/s21072418
25.
Nagahara
,
R.
, and
Morin
,
J.-B.
,
2018
, “
Sensor Insole for Measuring Temporal Variables and Vertical Force During Sprinting
,”
Proc. Inst. Mech. Eng., Part P J. Sports Eng. Technol.
,
232
(
4
), pp.
369
374
.10.1177/1754337117751730
26.
Giacomozzi
,
C.
,
Caravaggi
,
P.
,
Stebbins
,
J.
, and
Leardini
,
A.
,
2016
, “
Integration of Foot Pressure and Foot Kinematics Measurements for Medical Applications
,”
Handbook Human Motion
,
Springer
,
Cham
, pp.
1
22
.
27.
Eguchi
,
R.
, and
Takahashi
,
M.
,
2018
, “
Accessible Calibration of Insole Force Sensors Using the Wii Balance Board for Kinetic Gait Analysis
,”
2018 IEEE Sensors
,
IEEE
,
New Delhi, India
, Oct. 28–31, pp.
1
4
.10.1109/ICSENS.2018.8589813
28.
Wong
,
C.
,
Zhang
,
Z.-Q.
,
Lo
,
B.
, and
Yang
,
G.-Z.
,
2015
, “
Wearable Sensing for Solid Biomechanics: A Review
,”
IEEE Sens. J.
,
15
(
5
), pp.
2747
2760
.10.1109/JSEN.2015.2393883
29.
Bittencourt
,
N. F.
,
Meeuwisse
,
W.
,
Mendonça
,
L.
,
Nettel-Aguirre
,
A.
,
Ocarino
,
J.
, and
Fonseca
,
S.
,
2016
, “
Complex Systems Approach for Sports Injuries: Moving From Risk Factor Identification to Injury Pattern Recognition-Narrative Review and New Concept
,”
Br. J. Sports Med.
,
50
(
21
), pp.
1309
1314
.10.1136/bjsports-2015-095850
30.
Seiberl
,
W.
,
Jensen
,
E.
,
Merker
,
J.
,
Leitel
,
M.
, and
Schwirtz
,
A.
,
2018
, “
Accuracy and Precision of Loadsol® Insole Force-Sensors for the Quantification of Ground Reaction Force-Based Biomechanical Running Parameters
,”
Eur. J. Sport Sci.
,
18
(
8
), pp.
1100
1109
.10.1080/17461391.2018.1477993
31.
Ngueleu
,
A. M.
,
Blanchette
,
A. K.
,
Bouyer
,
L.
,
Maltais
,
D.
,
McFadyen
,
B. J.
,
Moffet
,
H.
, and
Batcho
,
C. S.
,
2019
, “
Design and Accuracy of an Instrumented Insole Using Pressure Sensors for Step Count
,”
Sensors
,
19
(
5
), p.
984
.10.3390/s19050984
You do not currently have access to this content.