Abstract

Uncontrollable shaking in the human wrist, caused by pathological tremor, can significantly undermine the power and accuracy in object manipulation. In this paper, the design of a tremor alleviating wrist exoskeleton (TAWE) is introduced. Unlike the works in the literature that only consider the flexion/extension (FE) motion, in this paper, we model the wrist joint as a constrained three-dimensional (3D) rotational joint accounting for the coupled FE and radial/ulnar deviation (RUD) motions. Hence TAWE, which features a six degrees-of-freedom (DOF) rigid linkage structure, aims to accurately monitor, suppress tremors, and provide light-power augmentation in both FE and RUD wrist motions. The presented study focuses on providing a fundamental understanding of the feasibility of TAWE through theoretical analyses. The analytical multibody modeling of the forearm–TAWE assembly provides insight into the necessary conditions for control, which indicates that reliable control conditions in the desired workspace can be acquired by tuning the design parameters. Nonlinear regressions are then implemented to identify the information that is crucial to the controller design from the unknown wrist kinematics. The proposed analytical model is validated numerically with V-REP and the result shows good agreement. Simulations also demonstrate the reliable performance of TAWE under controllers designed for tremor suppression and movement assistance.

References

1.
Louis
,
E. D.
,
2001
, “
Essential Tremor
,”
New Engl. J. Med.
,
345
(
12
), pp.
887
891
.10.1056/NEJMcp010928
2.
Benito-León
,
J.
, and
Louis
,
E. D.
,
2006
, “
Essential Tremor: Emerging Views of a Common Disorder
,”
Nat. Rev. Neurol.
,
2
(
12
), pp.
666
678
.10.1038/ncpneuro0347
3.
Jankovic
,
J.
,
2008
, “
Parkinson's Disease: Clinical Features and Diagnosis
,”
J. Neurol., Neurosurg. Psychiatry
,
79
(
4
), pp.
368
376
.10.1136/jnnp.2007.131045
4.
Kalia
,
L. V.
, and
Lang
,
A. E.
,
2015
, “
Parkinson's Disease
,”
Lancet
,
386
(
9996
), pp.
896
912
.10.1016/S0140-6736(14)61393-3
5.
Gnadinger
,
M.
, and
Hans-Ulrich Mellinghoff
,
A. K.-L.
,
2011
, “
Parkinson's Disease and the Bones
,”
Swiss Med. Wkly.
,
141
, p.
w13154
.10.4414/smw.2011.13154
6.
Pons
,
J. L.
,
2008
,
Wearable Robots: Biomechatronic Exoskeletons
,
Wiley
, Chichester, England.
7.
Fromme
,
N. P.
,
Camenzind
,
M.
,
Riener
,
R.
, and
Rossi
,
R. M.
,
2019
, “
Need for Mechanically and Ergonomically Enhanced Tremor-Suppression Orthoses for the Upper Limb: A Systematic Review
,”
J. Neuroeng. Rehabil.
,
16
(
1
), p.
93
.10.1186/s12984-019-0543-7
8.
Loureiro
,
R. C.
,
Belda-Lois
,
J. M.
,
Lima
,
E. R.
,
Pons
,
J. L.
,
Sanchez-Lacuesta
,
J. J.
, and
Harwin
,
W. S.
,
2005
, “
Upper Limb Tremor Suppression in Adl Via an Orthosis Incorporating a Controllable Double Viscous Beam Actuator
,”
IEEE Nineth International Conference on Rehabilitation Robotics 2005
(
ICORR 2005
), Chicago, IL, June 28–July 1, pp.
119
122
.10.1109/ICORR.2005.1501065
9.
Rocon
,
E.
,
Belda-Lois
,
J.
,
Ruiz
,
A.
,
Manto
,
M.
,
Moreno
,
J. C.
, and
Pons
,
J.
,
2007
, “
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
,”
IEEE Trans. Neural Syst. Rehabil. Eng.
,
15
(
3
), pp.
367
378
.10.1109/TNSRE.2007.903917
10.
Taheri
,
B.
,
2013
, “
Real-Time Pathological Tremor Identification and Suppression in Human Arm Via Active Orthotic Devices
,”
Ph.D. thesis
,
Southern Methodist University
, Dallas, TX.https://www.researchgate.net/publication/260079938_Real-Time_Pathological_Tremor_Identification_and_Suppression_in_Human_Arm_via_Active_Orthotic_Devices
11.
Huen
,
D.
,
Liu
,
J.
, and
Lo
,
B.
,
2016
, “
An Integrated Wearable Robot for Tremor Suppression With Context Aware Sensing
,” IEEE IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (
BSN
), San Francisco, CA, June 14–17, pp.
312
317
.10.1109/BSN.2016.7516280
12.
Anouti
,
A.
, and
Koller
,
W. C.
,
1995
, “
Tremor Disorders. diagnosis and Management
,”
West. J. Med.
,
162
(
6
), p.
510
.https://pubmed.ncbi.nlm.nih.gov/7618310/
13.
Riviere
,
C. N.
,
Rader
,
R. S.
, and
Thakor
,
N. V.
,
1998
, “
Adaptive Cancelling of Physiological Tremor for Improved Precision in Microsurgery
,”
IEEE Trans. Biomed. Eng.
,
45
(
7
), pp.
839
846
.10.1109/10.686791
14.
Veluvolu
,
K. C.
, and
Ang
,
W. T.
,
2011
, “
Estimation of Physiological Tremor From Accelerometers for Real-Time Applications
,”
Sensors
,
11
(
3
), pp.
3020
3036
.10.3390/s110303020
15.
Tatinati
,
S.
,
Veluvolu
,
K. C.
,
Hong
,
S.-M.
,
Latt
,
W. T.
, and
Ang
,
W. T.
,
2013
, “
Physiological Tremor Estimation With Autoregressive (ar) Model and Kalman Filter for Robotics Applications
,”
IEEE Sens. J.
,
13
(
12
), pp.
4977
4985
.10.1109/JSEN.2013.2271737
16.
Bo
,
A. P. L.
,
Poignet
,
P.
, and
Geny
,
C.
,
2011
, “
Pathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation
,”
IEEE Trans. Neural Syst. Rehabil. Eng.
,
19
(
2
), pp.
177
185
.10.1109/TNSRE.2010.2091283
17.
Li
,
Z.-M.
,
Kuxhaus
,
L.
,
Fisk
,
J. A.
, and
Christophel
,
T. H.
,
2005
, “
Coupling Between Wrist Flexion–Extension and Radial–Ulnar Deviation
,”
Clin. Biomech.
,
20
(
2
), pp.
177
183
.10.1016/j.clinbiomech.2004.10.002
18.
Moore
,
D. C.
,
Crisco
,
J. J.
,
Trafton
,
T. G.
, and
Leventhal
,
E. L.
,
2007
, “
A Digital Database of Wrist Bone Anatomy and Carpal Kinematics
,”
J. Biomech.
,
40
(
11
), pp.
2537
2542
.10.1016/j.jbiomech.2006.10.041
19.
Aydoğ
,
E.
,
Ekşioğlu
,
E.
,
Çakci
,
A.
, and
Yilmaz
,
Ö.
,
2005
, “
Hand Deformity in Parkinson's Disease: Case Report
,”
Rheumatol. Int.
,
25
(
7
), pp.
548
549
.10.1007/s00296-004-0543-0
20.
Gupta
,
A.
,
O'Malley
,
M. K.
,
Patoglu
,
V.
, and
Burgar
,
C.
,
2008
, “
Design, Control and Performance of Ricewrist: A Force Feedback Wrist Exoskeleton for Rehabilitation and Training
,”
Int. J. Rob. Res.
,
27
(
2
), pp.
233
251
.10.1177/0278364907084261
21.
Rose
,
C. G.
,
Pezent
,
E.
,
Kann
,
C. K.
,
Deshpande
,
A. D.
, and
O'Malley
,
M. K.
,
2018
, “
Assessing Wrist Movement With Robotic Devices
,”
IEEE Trans. Neural Syst. Rehabil. Eng.
,
26
(
8
), pp.
1585
1595
.10.1109/TNSRE.2018.2853143
22.
Perry
,
J. C.
,
Rosen
,
J.
, and
Burns
,
S.
,
2007
, “
Upper-Limb Powered Exoskeleton Design
,”
IEEE/ASME Trans. Mechatronics
,
12
(
4
), pp.
408
417
.10.1109/TMECH.2007.901934
23.
Wang
,
J.
,
Barry
,
O.
,
Kurdila
,
A. J.
, and
Vijayan
,
S.
,
2019
, “
On the Dynamics and Control of a Full Wrist Exoskeleton for Tremor Alleviation
,”
ASME
Paper No. DSCC2019-9118.10.1115/DSCC2019-9118
24.
Salvia
,
P.
,
Woestyn
,
L.
,
David
,
J. H.
,
Feipel
,
V.
,
Van
,
S.
,
Jan
,
S.
,
Klein
,
P.
, and
Rooze
,
M.
,
2000
, “
Analysis of Helical Axes, Pivot and Envelope in Active Wrist Circumduction
,”
Clin. Biomech.
,
15
(
2
), pp.
103
111
.10.1016/S0268-0033(99)00055-8
25.
Jan
,
S. V. S.
,
Salvia
,
P.
,
Hilal
,
I.
,
Sholukha
,
V.
,
Rooze
,
M.
, and
Clapworthy
,
G.
,
2002
, “
Registration of 6-DOFs Electrogoniometry and ct Medical Imaging for 3D Joint Modeling
,”
J. Biomech.
,
35
(
11
), pp.
1475
1484
.10.1016/S0021-9290(02)00074-X
26.
Li
,
W.
, and
Wang
,
J.
,
2013
, “
Effective Adaptive Kalman Filter for MEMS-IMU/Magnetometers Integrated Attitude and Heading Reference Systems
,”
J. Navig.
,
66
(
1
), pp.
99
113
.10.1017/S0373463312000331
27.
Diebel
,
J.
,
2006
, “
Representing Attitude: Euler Angles, Unit Quaternions, and Rotation Vectors
,”
Matrix
,
58
(
15–16
), pp.
1
35
.https://api.semanticscholar.org/CorpusID:16450526
28.
Fresk
,
E.
, and
Nikolakopoulos
,
G.
,
2013
, “
Full Quaternion Based Attitude Control for a Quadrotor
,”
IEEE European Control Conference
(
ECC
), Zurich, Switzerland, July 17–19, pp.
3864
3869
.10.23919/ECC.2013.6669617
29.
Formica
,
D.
,
Charles
,
S. K.
,
Zollo
,
L.
,
Guglielmelli
,
E.
,
Hogan
,
N.
, and
Krebs
,
H. I.
,
2012
, “
The Passive Stiffness of the Wrist and Forearm
,”
Am. J. Physiol.-Heart Circ. Physiol.
,
108
(
4
), pp.
1158
1166
.10.1152/jn.01014.2011
30.
Stiles
,
R. N.
,
1980
, “
Mechanical and Neural Feedback Factors in Postural Hand Tremor of Normal Subjects
,”
J. Neurophysiol.
,
44
(
1
), pp.
40
59
.10.1152/jn.1980.44.1.40
31.
Durbaba
,
R.
,
Cassidy
,
A.
,
Budini
,
F.
, and
Macaluso
,
A.
,
2013
, “
The Effects of Isometric Resistance Training on Stretch Reflex Induced Tremor in the Knee Extensor Muscles
,”
J. Appl. Physiol.
,
114
(
12
), pp.
1647
1656
.10.1152/japplphysiol.00917.2011
32.
Lemay
,
M. A.
, and
Crago
,
P. E.
,
1996
, “
A Dynamic Model for Simulating Movements of the Elbow, Forearm, and Wrist
,”
J. Biomech.
,
29
(
10
), pp.
1319
1330
.10.1016/0021-9290(96)00026-7
33.
Duprey
,
S.
,
Naaim
,
A.
,
Moissenet
,
F.
,
Begon
,
M.
, and
Cheze
,
L.
,
2017
, “
Kinematic Models of the Upper Limb Joints for Multibody Kinematics Optimisation: An Overview
,”
J. Biomech.
,
62
, pp.
87
94
.10.1016/j.jbiomech.2016.12.005
34.
Esmaeili
,
M.
,
Gamage
,
K.
,
Tan
,
E.
, and
Campolo
,
D.
,
2011
, “
Ergonomic Considerations for Anthropomorphic Wrist Exoskeletons: A Simulation Study on the Effects of Joint Misalignment
,”
IEEE/RSJ International Conference on Intelligent Robots and Systems
, San Francisco, Sept. 25–30, pp.
4905
4910
.10.1109/IROS.2011.6095136
35.
Esmaeili
,
M.
,
Jarrassé
,
N.
,
Dailey
,
W.
,
Bürdet
,
E.
, and
Campolo
,
D.
,
2013
, “
Hyperstaticity for Ergonomie Design of a Wrist Exoskeleton
,”
IEEE 13th International Conference on Rehabilitation Robotics
(
ICORR
), Seattle, WA, June 24–26, pp.
1
6
.10.1109/ICORR.2013.6650417
36.
Biryukova
,
E.
,
Roby-Brami
,
A.
,
Frolov
,
A.
, and
Mokhtari
,
M.
,
2000
, “
Kinematics of Human Arm Reconstructed From Spatial Tracking System Recordings
,”
J. Biomech.
,
33
(
8
), pp.
985
995
.10.1016/S0021-9290(00)00040-3
37.
Seth
,
A.
,
Hicks
,
J. L.
,
Uchida
,
T. K.
,
Habib
,
A.
,
Dembia
,
C. L.
,
Dunne
,
J. J.
,
Ong
,
C. F.
,
DeMers
,
M. S.
,
Rajagopal
,
A.
,
Millard
,
M.
,
Hamner
,
S. R.
,
Arnold
,
E. M.
,
Yong
,
J. R.
,
Lakshmikanth
,
S. K.
,
Sherman
,
M. A.
,
Ku
,
J. P.
, and
Delp
,
S. L.
,
2018
, “
Opensim: Simulating Musculoskeletal Dynamics and Neuromuscular Control to Study Human and Animal Movement
,”
PLoS Comput. Biol.
,
14
(
7
), p.
e1006223
.10.1371/journal.pcbi.1006223
38.
Marquardt
,
D. W.
,
1963
, “
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
,”
J. Soc. Ind. Appl. Math.
,
11
(
2
), pp.
431
441
.10.1137/0111030
39.
Haykin
,
S. S.
,
2014
,
Adaptive Filter Theory
,
Pearson Education Ltd.
, Harlow, England.
40.
Skogestad
,
S.
, and
Postlethwaite
,
I.
,
2007
,
Multivariable Feedback Control: Analysis and Design
, Vol.
2
,
Wiley
,
New York
.
41.
Wang
,
J.
,
Kamidi
,
V. R.
, and
Ben-Tzvi
,
P.
,
2018
, “
A Multibody Toolbox for Hybrid Dynamic System Modeling Based on Nonholonomic Symbolic Formalism
,”
ASME
Paper No. DSCC2018-9000.10.1115/DSCC2018-9000
42.
E.
,
Rohmer
,
S. P. N.
, and
Singh
,
M. F.
,
2013
, “
V-Rep: A Versatile and Scalable Robot Simulation Framework
,”
Proceedings of the International Conference on Intelligent Robots and Systems
(
IROS
), Tokyo, Japan, Nov. 3–7, pp.
1321
1326
.10.1109/IROS.2013.6696520
You do not currently have access to this content.