The objective of this study was to investigate the process of mandibular bone remodeling induced by implant-supported overdentures. computed tomography (CT) images were collected from edentulous patients to reconstruct the geometry of the mandibular bone and overdentures supported by implants. Based on the theory of strain energy density (SED), bone remodeling models were established using the user material subroutine (UMAT) in abaqus. The stress distribution in the mandible and bone density change was investigated to determine the effect of implant number on the remodeling of the mandibular bone. The results indicated that the areas where high Mises stress values were observed were mainly situated around the implants. The stress was concentrated in the distal neck region of the distal-most implants. With an increased number of implants, the biting force applied on the dentures was almost all taken up by implants. The stress and bone density in peri-implant bone increased. When the stress reached the threshold of remodeling, the bone density began to decrease. In the posterior mandible area, the stress was well distributed but increased with decreased implant numbers. Changes in bone density were not observed in this area. The computational results were consistent with the clinical data. The results demonstrate that the risk of bone resorption around the distal-most implants increases with increased numbers of implants and that the occlusal force applied to overdentures should be adjusted to be distributed more in the distal areas of the mandible.

References

1.
Doundoulakis
,
J. H.
,
Eckert
,
S. E.
,
Lindquist
,
C. C.
, and
Jeffcoat
,
M. K.
,
2003
, “
The Implant-Supported Overdenture as an Alternative to the Complete Mandibular Denture
,”
J. Am. Dent. Assoc.
,
134
(
11
), pp.
1455
1458
.
2.
Redford
,
M.
,
Drury
,
T. F.
,
Kingman
,
A.
, and
Brown
,
L. J.
,
1996
, “
Denture Use and the Technical Quality of Dental Prostheses Among Persons 18–74 Years of Age: United States, 1988–1991
,”
J. Dent. Res.
,
75
, pp.
714
725
.
3.
Burns
,
D. R.
,
2000
, “
Mandibular Implant Overdenture Treatment: Consensus and Controversy
,”
J. Prosthodontics
,
9
(
1
), pp.
37
46
.
4.
Engquist
,
B.
,
Bergendal
,
T.
,
Kallus
,
T.
, and
Linden
,
U.
,
1988
, “
A Retrospective Multicenter Evaluation of Osseointegrated Implants Supporting Overdentures
,”
Int. J. Oral Maxillofac. Implants
,
3
(
2
), pp.
129
134
.
5.
Johns
,
R. B.
,
Jemt
,
T.
,
Heath
,
M. R.
,
Hutton
,
J. E.
,
McKenna
,
S.
,
McNamara
,
D. C.
,
van Steenberghe
,
D.
,
Taylor
,
R.
,
Watson
,
R. M.
, and
Herrmann
,
I.
,
1992
, “
A Multicenter Study of Overdentures Supported by Branemark Implants
,”
Int. J. Oral Maxillofac. Implants
,
7
(
4
), pp.
513
522
.
6.
Bergendal
,
T.
, and
Engquist
,
B.
,
1998
, “
Implant-Supported Overdentures: A Longitudinal Prospective Study
,”
Int. J. Oral Maxillofac. Implants
,
13
(
2
), pp.
253
262
.
7.
Mericske-Stern
,
R.
,
1990
, “
Clinical Evaluation of Overdenture Restorations Supported by Osseointegrated Titanium Implants: A Retrospective Study
,”
Int. J. Oral Maxillofac. Implants
,
5
(
4
), pp.
375
383
.
8.
Liu
,
J.
,
Pan
,
S.
,
Dong
,
J.
,
Mo
,
Z.
,
Fan
,
Y.
, and
Feng
,
H.
,
2013
, “
Influence of Implant Number on the Biomechanical Behaviour of Mandibular Implant-Retained/Supported Overdentures: A Three-Dimensional Finite Element Analysis
,”
J. Dent.
,
41
(
3
), pp.
241
249
.
9.
Heckmann
,
S. M.
,
Winter
,
W.
,
Meyer
,
M.
,
Weber
,
H. P.
, and
Wichmann
,
M. G.
,
2001
, “
Overdenture Attachment Selection and the Loading of Implant and Denture-Bearing Area. Part 2: A Methodical Study Using Five Types of Attachment
,”
Clin. Oral Implants Res.
,
12
(
6
), pp.
640
647
.
10.
Porter
,
J. A.
, Jr.
,
Petropoulos
,
V. C.
, and
Brunski
,
J. B.
,
2002
, “
Comparison of Load Distribution for Implant Overdenture Attachments
,”
Int. J. Oral Maxillofac. Implants
,
17
(
5
), pp.
651
662
.
11.
Mericske-Stern
,
R. D.
,
Taylor
,
T. D.
, and
Belser
,
U.
,
2000
, “
Management of the Edentulous Patient
,”
Clin. Oral Implants Res.
,
11
(
Suppl. 1
), pp.
108
125
.
12.
Kronstrom
,
M.
,
Davis
,
B.
,
Loney
,
R.
,
Gerrow
,
J.
, and
Hollender
,
L.
,
2010
, “
A Prospective Randomized Study on the Immediate Loading of Mandibular Overdentures Supported by One or Two Implants: A 12-Month Follow-Up Report
,”
Int. J. Oral Maxillofac. Implants
,
25
(
1
), pp.
181
188
.
13.
Liddelow
,
G.
, and
Henry
,
P.
,
2010
, “
The Immediately Loaded Single Implant-Retained Mandibular Overdenture: A 36-Month Prospective Study
,”
Int. J. Prosthodontics
,
23
(
1
), pp.
13
21
.
14.
Ben-Ur
,
Z.
,
Gorfil
,
C.
, and
Shifman
,
A.
,
1996
, “
Anterior Implant-Supported Overdentures
,”
Quintessence Int.
,
27
(
9
), pp.
603
606
.
15.
Meijer
,
H. J.
,
Raghoebar
,
G. M.
,
Batenburg
,
R. H.
,
Visser
,
A.
, and
Vissink
,
A.
,
2009
, “
Mandibular Overdentures Supported by Two or Four Endosseous Implants: A 10-Year Clinical Trial
,”
Clin. Oral Implants Res.
,
20
(
7
), pp.
722
728
.
16.
Li
,
J.
,
Li
,
H.
,
Shi
,
L.
,
Fok
,
A. S.
,
Ucer
,
C.
,
Devlin
,
H.
,
Horner
,
K.
, and
Silikas
,
N.
,
2007
, “
A Mathematical Model for Simulating the Bone Remodeling Process Under Mechanical Stimulus
,”
Dent. Mater.
,
23
(
9
), pp.
1073
1078
.
17.
Lian
,
Z.
,
Guan
,
H.
,
Ivanovski
,
S.
,
Loo
,
Y. C.
,
Johnson
,
N. W.
, and
Zhang
,
H.
,
2010
, “
Effect of Bone to Implant Contact Percentage on Bone Remodelling Surrounding a Dental Implant
,”
Int. J. Oral Maxillofac. Surg.
,
39
(
7
), pp.
690
698
.
18.
Mellal
,
A.
,
Wiskott
,
H. W.
,
Botsis
,
J.
,
Scherrer
,
S. S.
, and
Belser
,
U. C.
,
2004
, “
Stimulating Effect of Implant Loading on Surrounding Bone. Comparison of Three Numerical Models and Validation by In Vivo Data
,”
Clin. Oral Implants Res.
,
15
(
2
), pp.
239
248
.
19.
Kitamura
,
E.
,
Stegaroiu
,
R.
,
Nomura
,
S.
, and
Miyakawa
,
O.
,
2004
, “
Biomechanical Aspects of Marginal Bone Resorption Around Osseointegrated Implants: Considerations Based on a Three-Dimensional Finite Element Analysis
,”
Clin. Oral Implants Res.
,
15
(
4
), pp.
401
412
.
20.
Akca
,
K.
, and
Cehreli
,
M. C.
,
2006
, “
Biomechanical Consequences of Progressive Marginal Bone Loss around Oral Implants: A Finite Element Stress Analysis
,”
Med. Biol. Eng. Comput.
,
44
(
7
), pp.
527
535
.
21.
Baggi
,
L.
,
Cappelloni
,
I.
,
Di Girolamo
,
M.
,
Maceri
,
F.
, and
Vairo
,
G.
,
2008
, “
The Influence of Implant Diameter and Length on Stress Distribution of Osseointegrated Implants Related to Crestal Bone Geometry: A Three-Dimensional Finite Element Analysis
,”
J. Prosthetic Dent.
,
100
(
6
), pp.
422
431
.
22.
Boccaccio
,
A.
,
Kelly
,
D. J.
, and
Pappalettere
,
C.
,
2012
, “
A Model of Tissue Differentiation and Bone Remodelling in Fractured Vertebrae Treated With Minimally Invasive Percutaneous Fixation
,”
Med. Biol. Eng. Comput.
,
50
(
9
), pp.
947
959
.
23.
Koos
,
B.
,
Godt
,
A.
,
Schille
,
C.
, and
Göz
,
G.
,
2010
, “
Precision of an Instrumentation-Based Method of Analyzing Occlusion and Its Resulting Distribution of Forces in the Dental Arch
,”
J. Orofacial Orthop.
,
71
(
6
), pp.
403
410
.
24.
Van Oosterwyck
,
H.
,
Duyck
,
J.
,
Vander Sloten
,
J.
,
Van der Perre
,
G.
,
De Cooman
,
M.
,
Lievens
,
S.
,
Puers
,
R.
, and
Naert
,
I.
,
1998
, “
The Influence of Bone Mechanical Properties and Implant Fixation Upon Bone Loading Around Oral Implants
,”
Clin. Oral Implants Res.
,
9
(
6
), pp.
407
418
.
25.
Cattaneo
,
P. M.
,
Dalstra
,
M.
, and
Melsen
,
B.
,
2005
, “
The Finite Element Method: A Tool to Study Orthodontic Tooth Movement
,”
J. Dent. Res.
,
84
(
5
), pp.
428
433
.
26.
Daas
,
M.
,
Dubois
,
G.
,
Bonnet
,
A. S.
,
Lipinski
,
P.
, and
Rignon-Bret
,
C.
,
2008
, “
A Complete Finite Element Model of a Mandibular Implant-Retained Overdenture With Two Implants: Comparison Between Rigid and Resilient Attachment Configurations
,”
Med. Eng. Phys.
,
30
(
2
), pp.
218
225
.
27.
Geramy
,
A.
,
2000
, “
Alveolar Bone Resorption and the Center of Resistance Modification (3-D Analysis by Means of the Finite Element Method)
,”
Am. J. Orthod. Dentofacial. Orthop.
,
117
(
4
), pp.
399
405
.
28.
Holmes
,
D. C.
,
Diaz-Arnold
,
A. M.
, and
Leary
,
J. M.
,
1996
, “
Influence of Post Dimension on Stress Distribution in Dentin
,”
J. Prosthetic Dent.
,
75
(
2
), pp.
140
147
.
29.
Helgason
,
B.
,
Perilli
,
E.
,
Schileo
,
E.
,
Taddei
,
F.
,
Brynjolfsson
,
S.
, and
Viceconti
,
M.
,
2008
, “
Mathematical Relationships Between Bone Density and Mechanical Properties: A Literature Review
,”
Clin. Biomech.
,
23
(
2
), pp.
135
146
.
30.
Holmes
,
D. C.
, and
Loftus
,
J. T.
,
1997
, “
Influence of Bone Quality on Stress Distribution for Endosseous Implants
,”
J. Oral Implantology
,
23
(
3
), pp.
104
111
.
31.
Brunski
,
J. B.
,
Puleo
,
D. A.
, and
Nanci
,
A.
,
2000
, “
Biomaterials and Biomechanics of Oral and Maxillofacial Implants: Current Status and Future Developments
,”
Int. J. Oral Maxillofac. Implants
,
15
(
1
), pp.
15
46
.
32.
Menicucci
,
G.
,
Lorenzetti
,
M.
,
Pera
,
P.
, and
Preti
,
G.
,
1998
, “
Mandibular Implant-Retained Overdenture: Finite Element Analysis of Two Anchorage Systems
,”
Int. J. Oral Maxillofac. Implants
,
13
(
3
), pp.
369
376
.
33.
Weinans
,
H.
,
Huiskes
,
R.
, and
Grootenboer
,
H. J.
,
1992
, “
The Behavior of Adaptive Bone-Remodeling Simulation Models
,”
J. Biomech.
,
25
(
12
), pp.
1425
1441
.
34.
Zhao
,
Y.
,
Wang
,
W.
,
Xin
,
H.
,
Zang
,
S.
,
Zhang
,
Z.
, and
Wu
,
Y.
,
2013
, “
The Remodeling of Alveolar Bone Supporting the Mandibular First Molar With Different Levels of Periodontal Attachment
,”
Med. Biol. Eng. Comput.
,
51
(
9
), pp.
991
997
.
35.
Rungsiyakull
,
C.
,
Rungsiyakull
,
P.
,
Li
,
Q.
,
Li
,
W.
, and
Swain
,
M.
,
2011
, “
Effects of Occlusal Inclination and Loading on Mandibular Bone Remodeling: A Finite Element Study
,”
Int. J. Oral Maxillofac. Implants
,
26
(
3
), pp.
527
537
.
36.
Chen
,
G.
,
Pettet
,
G.
,
Pearcy
,
M.
, and
McElwain
,
D. L.
,
2007
, “
Comparison of Two Numerical Approaches for Bone Remodelling
,”
Med. Eng. Phys.
,
29
(
1
), pp.
134
139
.
37.
Maeda
,
Y.
, and
Wood
,
W. W.
,
1989
, “
Finite Element Method Simulation of Bone Resorption Beneath a Complete Denture
,”
J. Dent. Res.
,
68
(
9
), pp.
1370
1373
.
38.
Davis
,
W. H.
,
Lam
,
P. S.
,
Marshall
,
M. W.
,
Dorchester
,
W.
,
Hochwald
,
D. A.
, and
Kaminishi
,
R. M.
,
1999
, “
Using Restorations Borne Totally by Anterior Implants to Preserve the Edentulous Mandible
,”
J. Am. Dent. Assoc.
,
130
(
8
), pp.
1183
1189
.
39.
Chen
,
J.
,
Ahmad
,
R.
,
Suenaga
,
H.
,
Li
,
W.
,
Swain
,
M.
, and
Li
,
Q.
,
2015
, “
A Comparative Study on Complete and Implant Retained Denture Treatments—A Biomechanics Perspective
,”
J. Biomech.
,
48
(
3
), pp.
512
519
.
40.
Topkaya
,
T.
, and
Solmaz
,
M. Y.
,
2015
, “
The Effect of Implant Number and Position on the Stress Behavior of Mandibular Implant Retained Overdentures: A Three-Dimensional Finite Element Analysis
,”
J. Biomech.
,
48
(
10
), pp.
2102
2109
.
You do not currently have access to this content.