Drug-eluting stents have a significant clinical advantage in late-stage restenosis due to the antiproliferative drug release. Understanding how drug transport occurs between coronary arterial locations can better help guide localized drug treatment options. Finite element models with properties from specific porcine coronary artery sections (left anterior descending (LAD), right (RCA); proximal, middle, distal regions) were created for stent deployment and drug delivery simulations. Stress, strain, pore fluid velocity, and drug concentrations were exported at different time points of simulation (0–180 days). Tests indicated that the highest stresses occurred in LAD sections. Higher-than-resting homeostatic levels of stress and strain existed at upwards of 3.0 mm away from the stented region, whereas concentration of species only reached 2.7 mm away from the stented region. Region-specific concentration showed 2.2 times higher concentrations in RCA artery sections at times corresponding to vascular remodeling (peak in the middle segment) compared to all other segments. These results suggest that wall transport can occur differently based on coronary artery location. Awareness of peak growth stimulators and where drug accumulation occurs in the vasculature can better help guide local drug delivery therapies.

References

References
1.
Hwang
,
C. W.
,
Wu
,
D.
, and
Edelman
,
E. R.
,
2001
, “
Physiological Transport Forces Govern Drug Distribution for Stent-Based Delivery
,”
Circulation
,
104
(
5
), pp.
600
605
.10.1161/hc3101.092214
2.
Hwang
,
C. W.
,
Wu
,
D.
, and
Edelman
,
E. R.
,
2003
, “
Impact of Transport and Drug Properties on the Local Pharmacology of Drug-Eluting Stents
,”
Int. J. Cardiovasc. Interv.
,
5
(
1
), pp.
7
12
. Available at: http://web.mit.edu/hst-program/erelab/Publications/2003%20Papers/HwangImpactReview2003.pdf
3.
Kang
,
S. J.
,
Mintz
,
G. S.
,
Park
,
D. W.
,
Lee
,
S. W.
,
Kim
,
Y. H.
,
Whan Lee
,
C.
,
Han
,
K. H.
,
Kim
,
J. J.
,
Park
,
S. W.
, and
Park
,
S. J.
,
2011
, “
Mechanisms of In-Stent Restenosis After Drug-Eluting Stent Implantation: Intravascular Ultrasound Analysis
,”
Circul. Cardiovasc. Interv.
,
4
(
1
), pp.
9
14
.10.1161/CIRCINTERVENTIONS.110.940320
4.
Keyes
,
J. T.
,
Lockwood
,
D. R.
,
Simon
,
B. R.
, and
Vande Geest
,
J. P.
,
2013
, “
Deformationally Dependent Fluid Transport Properties of Porcine Coronary Arteries Based on Location in the Coronary Vasculature
,”
J. Mech. Bev. Biomed. Mat.
,
17
, pp.
296
306
.10.1016/j.jmbbm.2012.10.002
5.
Levin
,
A. D.
,
Vukmirovic
,
N.
,
Hwang
,
C. W.
, and
Edelman
,
E. R.
,
2004
, “
Specific Binding to Intracellular Proteins Determines Arterial Transport Properties for Rapamycin and Paclitaxel
,”
PNAS USA
,
101
(
25
), pp.
9463
9467
.10.1073/pnas.0400918101
6.
Lovich
,
M. A.
,
Creel
,
C.
,
Hong
,
K.
,
Hwang
,
C. W.
, and
Edelman
,
E. R.
,
2001
, “
Carrier Proteins Determine Local Pharmacokinetics and Arterial Distribution of Paclitaxel
,”
J. Pharm. Sci.
,
90
(
9
), pp.
1324
1335
.10.1002/jps.1085
7.
Wan
,
W. K.
,
Lovich
,
M. A.
,
Hwang
,
C. W.
, and
Edelman
,
E. R.
,
1999
, “
Measurement of Drug Distribution in Vascular Tissue Using Quantitative Fluorescence Microscopy
,”
J. Pharm. Sci.
,
88
(
8
), pp.
822
829
.10.1021/js9803858
8.
Zhu
,
X.
,
Pack
,
D. W.
, and
Braatz
,
R. D.
,
2012
, “
Modelling Intravascular Delivery From Drug-Eluting Stents With Biodurable Coating: Investigation of Anisotropic Vascular Drug Diffusivity and Arterial Drug Distribution
,”
Comput. Meth. Biomech. Biomed. Eng.
(in press).10.1080/10255842.2012.672815
9.
Samady
,
H.
,
Eshtehardi
,
P.
,
McDaniel
,
M. C.
,
Suo
,
J.
,
Dhawan
,
S. S.
,
Maynard
,
C.
,
Timmins
,
L. H.
,
Quyyumi
,
A. A.
, and
Giddens
,
D. P.
,
2011
, “
Coronary Artery Wall Shear Stress Is Associated With Progression and Transformation of Atherosclerotic Plaque and Arterial Remodeling in Patients With Coronary Artery Disease
,”
Circulation
,
124
(
7
), pp.
779
788
.10.1161/CIRCULATIONAHA.111.021824
10.
He
,
X.
, and
Ku
,
D. N.
,
1996
, “
Pulsatile Flow in the Human Left Coronary Artery Bifurcation: Average Conditions
,”
ASME, J. Biomech. Eng.
,
118
(
1
), pp.
74
82
.10.1115/1.2795948
11.
Krams
,
R.
,
Wentzel
,
J. J.
,
Oomen
,
J. A.
,
Vinke
,
R.
,
Schuurbiers
,
J. C.
,
de Feyter
,
P. J.
,
Serruys
,
P. W.
, and
Slager
,
C. J.
,
1997
, “
Evaluation of Endothelial Shear Stress and 3D Geometry as Factors Determining the Development of Atherosclerosis and Remodeling in Human Coronary Arteries In Vivo. Combining 3D Reconstruction From Angiography and IVUS (ANGUS) With Computational Fluid Dynamics
,”
Arteriosc. Throm. Vasc. Biol.
,
17
(
10
), pp.
2061
2065
.10.1161/01.ATV.17.10.2061
12.
Weydahl
,
E. S.
, and
Moore
,
J. E.
,
2001
, “
Dynamic Curvature Strongly Affects Wall Shear Rates in a Coronary Artery Bifurcation Model
,”
J. Biomech.
,
34
(
9
), pp.
1189
1196
.10.1016/S0021-9290(01)00051-3
13.
Plata
,
A. M.
,
Sherwin
,
S. J.
, and
Krams
,
R.
,
2010
, “
Endothelial Nitric Oxide Production and Transport in Flow Chambers: The Importance of Convection
,”
Ann. Biomed. Eng.
,
38
(
9
), pp.
2805
2816
.10.1007/s10439-010-0039-x
14.
Tarbell
,
J. M.
,
2003
, “
Mass Transport in Arteries and the Localization of Atherosclerosis
,”
Ann. Rev. Biomed. Eng.
,
5
, pp.
79
118
.10.1146/annurev.bioeng.5.040202.121529
15.
O'Connell
,
B. M.
,
McGloughlin
,
T. M.
, and
Walsh
,
M. T.
,
2010
, “
Factors That Affect Mass Transport From Drug Eluting Stents Into the Artery Wall
,”
Biomed. Eng. Online
,
9
, p.
15
.10.1186/1475-925X-9-15
16.
Keyes
,
J. T.
,
Simon
,
B. R.
, and
Vande Geest
,
J. P.
,
2012
, “
Location Dependent Coronary Artery Diffusive and Convective Mass Transport Properties of a Lipophilic Drug Surrogate Measured Using Nonlinear Microscopy
,”
Pharm. Res.
,
30
(
4
), pp.
1147
1160
.10.1007/s11095-012-0950-y
17.
Feenstra
,
P. H.
, and
Taylor
,
C. A.
,
2009
, “
Drug Transport in Artery Walls: A Sequential Porohyperelastic-Transport Approach
,”
Comput. Meth. Biomech. Biomed. Eng
,
12
(
3
), pp.
263
276
.10.1080/10255840802459396
18.
Wang
,
Z.
,
Sun
,
A.
,
Fan
,
Y.
, and
Deng
,
X.
,
2012
, “
Comparative Study of Newtonian and Non-Newtonian Simulations of Drug Transport in a Model Drug-Eluting Stent
,”
Biorheology
,
49
(
4
), pp.
249
259
.
19.
Balakrishnan
,
B.
,
Dooley
,
J. F.
,
Kopia
,
G.
, and
Edelman
,
E. R.
,
2007
, “
Intravascular Drug Release Kinetics Dictate Arterial Drug Deposition, Retention, and Distribution
,”
J. Control. Release
,
123
(
2
), pp.
100
108
.10.1016/j.jconrel.2007.06.025
20.
Goriely
,
A. R.
,
Baldwin
,
A. L.
, and
Secomb
,
T. W.
,
2007
, “
Transient Diffusion of Albumin in Aortic Walls: Effects of Binding to Medial Elastin Layers
,”
Am. J. Physiol.
,
292
(
5
), pp.
H2195
H2201
.10.1152/ajpheart.01294.2006
21.
Balakrishnan
,
B.
,
Tzafriri
,
A. R.
,
Seifert
,
P.
,
Groothuis
,
A.
,
Rogers
,
C.
, and
Edelman
,
E. R.
,
2005
, “
Strut Position, Blood Flow, and Drug Deposition: Implications for Single and Overlapping Drug-Eluting Stents
,”
Circulation
,
111
(
22
), pp.
2958
2965
.10.1161/CIRCULATIONAHA.104.512475
22.
Kolachalama
,
V. B.
,
Levine
,
E. G.
, and
Edelman
,
E. R.
,
2009
, “
Luminal Flow Amplifies Stent-Based Drug Deposition in Arterial Bifurcations
,”
PLoS One
,
4
(
12
), p.
e8105
.10.1371/journal.pone.0008105
23.
Kolachalama
, V
. B.
,
Tzafriri
,
A. R.
,
Arifin
,
D. Y.
, and
Edelman
,
E. R.
,
2009
, “
Luminal Flow Patterns Dictate Arterial Drug Deposition in Stent-Based Delivery
,”
J. Control. Release
,
133
(
1
), pp.
24
30
.10.1016/j.jconrel.2008.09.075
24.
Rappitsch
,
G.
, and
Perktold
,
K.
,
1996
, “
Pulsatile Albumin Transport in Large Arteries: A Numerical Simulation Study
,”
ASME, J. Biomech. Eng.
,
118
(
4
), pp.
511
519
.10.1115/1.2796038
25.
Vairo
,
G.
,
Cioffi
,
M.
,
Cottone
,
R.
,
Dubini
,
G.
, and
Migliavacca
,
F.
,
2010
, “
Drug Release From Coronary Eluting Stents: A Multidomain Approach
,”
J. Biomech.
,
43
(
8
), pp.
1580
1589
.10.1016/j.jbiomech.2010.01.033
26.
Vande Geest
,
J. P.
,
Simon
,
B. R.
,
Rigby
,
P. H.
, and
Newberg
,
T. P.
,
2011
, “
Coupled Porohyperelastic Mass Transport (PHEXPT) Finite Element Models for Soft Tissues Using ABAQUS
,”
ASME, J. Biomech. Eng.
,
133
(
4
), p.
044502
.10.1115/1.4003489
27.
Ayyalasomayajula
,
A.
,
Vande Geest
,
J. P.
, and
Simon
,
B. R.
,
2010
, “
Porohyperelastic Finite Element Modeling of abdominal Aortic Aneurysms
,”
ASME, J. Biomech. Eng.
,
132
(
10
), p.
104502
.10.1115/1.4002370
28.
Simulia
,
2010
, “
Abaqus 6.98 Documentation
,”
Abaqus Theory Manual
,
D. Systemes
,
ed.France
.
29.
Holzapfel
,
G. A.
, and
Weizsacker
,
H. W.
,
1998
, “
Biomechanical Behavior of the Arterial Wall and Its Numerical Characterization
,”
Comput. Biol. Med.
,
28
(
4
), pp.
377
392
.10.1016/S0010-4825(98)00022-5
30.
Medtronic
,
I.
,
2012
, “
Resolute Integrity Zotarolimus-Eluting Coronary Stent System Over the Wire Delivery System: Instructions for Use
.”
31.
Medtronic
,
I.
,
2012
, “
FDA Summary of Safety and Effectiveness Data (SSED) PMA Number: P110013
,”
F. a. D. Administration
, ed.
32.
Dirschinger
,
J.
,
Kastrati
,
A.
,
Neumann
,
F. J.
,
Boekstegers
,
P.
,
Elezi
,
S.
,
Mehilli
,
J.
,
Schuhlen
,
H.
,
Pache
,
J.
,
Alt
,
E.
,
Blasini
,
R.
,
Steinbeck
,
G.
, and
Schomig
,
A.
,
1999
, “
Influence of Balloon Pressure During Stent Placement in Native Coronary Arteries on Early and Late Angiographic and Clinical Outcome: A Randomized Evaluation of High-Pressure Inflation
,”
Circulation
,
100
(
9
), pp.
918
923
.10.1161/01.CIR.100.9.918
33.
Meredith
,
I. T.
,
Worthley
,
S.
,
Whitbourn
,
R.
,
Walters
,
D.
,
Popma
,
J.
,
Cutlip
,
D.
, and
Fitzgerald
,
P.
,
2007
, “
The Next-Generation Endeavor Resolute Stent: 4-Month Clinical and Angiographic Results From the Endeavor Resolute First-In-Man Trial
,”
EuroIntervention
,
3
(
1
), pp.
50
53
.
34.
Meredith
,
I. T.
,
Ormiston
,
J.
,
Whitbourn
,
R.
,
Kay
,
I. P.
,
Muller
,
D.
,
Popma
,
J. J.
,
Cutlip
,
D. E.
, and
Fitzgerald
,
P. J.
,
2007
, “
Four-Year Clinical Follow-Up After Implantation of the Endeavor Zotarolimus-Eluting Stent: ENDEAVOR I, The First-In-Human Study
,”
Am. J. Cardiol.
,
100
(
8B
), pp.
56M
61M
.10.1016/j.amjcard.2007.08.023
35.
Seiler
,
C.
,
Fleisch
,
M.
,
Kaufmann
,
U.
, and
Meier
,
B.
,
1997
, “
Measurements of Intracoronary Pressure and Blood Flow Velocity
,”
Praxis
,
86
(
16
), pp.
649
654
.
36.
Seiler
,
C.
,
Kaufmann
,
U.
, and
Meier
,
B.
,
1997
, “
Intracoronary Demonstration of Adenosine-Induced Coronary Collateral Steal
,”
Heart
,
77
(
1
), pp.
78
81
.
37.
Huo
,
Y.
, and
Kassab
,
G. S.
,
2006
, “
Pulsatile Blood Flow in the Entire Coronary Arterial Tree: Theory and Experiment
,”
Am. J. Physiol.
,
291
(
3
), pp.
H1074
H1087
.10.1152/ajpheart.00200.2006
38.
Ethier
,
C. R.
,
2002
, “
Computational Modeling of Mass Transfer and Links to Atherosclerosis
,”
Ann. Biomed. Eng.
,
30
(
4
), pp.
461
471
.10.1114/1.1468890
39.
Yang
,
C.
, and
Burt
,
H. M.
,
2006
, “
Drug-Eluting Stents: factors Governing Local Pharmacokinetics
,”
Adv. Drug Del. Rev.
,
58
(
3
), pp.
402
411
.10.1016/j.addr.2006.01.017
40.
Rogers
,
C.
,
Tseng
,
D. Y.
,
Squire
,
J. C.
, and
Edelman
,
E. R.
,
1999
, “
Balloon-Artery Interactions During Stent Placement: A Finite Element Analysis Approach to Pressure, Compliance, and Stent Design as Contributors to Vascular Injury
,”
Circul. Res.
,
84
(
4
), pp.
378
383
.10.1161/01.RES.84.4.378
41.
Hwang
,
C. W.
, and
Edelman
,
E. R.
,
2002
, “
Arterial Ultrastructure Influences Transport of Locally Delivered Drugs
,”
Circul. Res.
,
90
(
7
), pp.
826
832
.10.1161/01.RES.0000016672.26000.9E
42.
Fischer
,
G. M.
, and
Llaurado
,
J. G.
,
1966
, “
Collagen and Elastin Content in Canine Arteries Selected From Functionally Different Vascular Beds
,”
Circul. Res.
,
19
(
2
), pp.
394
399
.10.1161/01.RES.19.2.394
43.
Swindle
,
M. M.
,
Horneffer
,
P. J.
,
Gardner
,
T. J.
,
Gott
, V
. L.
,
Hall
,
T. S.
,
Stuart
,
R. S.
,
Baumgartner
,
W. A.
,
Borkon
,
A. M.
,
Galloway
,
E.
, and
Reitz
,
B. A.
,
1986
, “
Anatomic and Anesthetic Considerations in Experimental Cardiopulmonary Surgery in Swine
,”
Lab. Animal Sci.
,
36
(
4
), pp.
357
361
.
44.
Vilahur
,
G.
,
Padro
,
T.
, and
Badimon
,
L.
,
2011
, “
Atherosclerosis and Thrombosis: Insights From Large Animal Models
,”
J. Biomed. Biotech.
,
2011
, p.
907575
.10.1155/2011/907575
45.
Denardo
,
S. J.
,
Carpinone
,
P. L.
,
Vock
,
D. M.
,
Batich
,
C. D.
, and
Pepine
,
C. J.
,
2012
, “
Changes to Polymer Surface of Drug-Eluting Stents During Balloon Expansion
,”
JAMA
,
307
(
20
), pp.
2148
2150
.10.1001/jama.2012.4111
46.
Wakabayashi
,
K.
,
Mintz
,
G. S.
,
Weissman
,
N. J.
,
Stone
,
G. W.
,
Ellis
,
S. G.
,
Grube
,
E.
,
Ormiston
,
J. A.
,
Turco
,
M. A.
,
Pakala
,
R.
,
Xue
,
Z.
,
Desale
,
S.
,
Laynez-Carnicero
,
A.
,
Romaguera
,
R.
,
Sardi
,
G.
,
Pichard
,
A. D.
, and
Waksman
,
R.
,
2012
, “
Impact of Drug-Eluting Stents on Distal Vessels
,”
Circul. Cardiovasc. Interv.
,
5
(
2
), pp.
211
219
.10.1161/CIRCINTERVENTIONS.111.965780
47.
Baldwin
,
A. L.
,
Wilson
,
L. M.
,
Gradus-Pizlo
,
I.
,
Wilensky
,
R.
, and
March
,
K.
,
1997
, “
Effect of Atherosclerosis on Transmural Convection an Arterial Ultrastructure. Implications for Local Intravascular Drug Delivery
,”
Arteriosc. Throm. Vasc. Biol.
,
17
(
12
), pp.
3365
3375
.10.1161/01.ATV.17.12.3365
48.
Lovich
,
M. A.
,
Philbrook
,
M.
,
Sawyer
,
S.
,
Weselcouch
,
E.
, and
Edelman
,
E. R.
,
1998
, “
Arterial Heparin Deposition: Role of Diffusion, Convection, and Extravascular Space
,”
Am. J. Physiol.
,
275
(
6
), pp.
H2236
2242
.
49.
Boerckel
,
J. D.
,
Uhrig
,
B. A.
,
Willett
,
N. J.
,
Huebsch
,
N.
, and
Guldberg
,
R. E.
,
2011
, “
Mechanical Regulation of Vascular Growth and Tissue Regeneration In Vivo
,”
PNAS USA
,
108
(
37
), pp.
E674
E680
.10.1073/pnas.1107019108
50.
Humphrey
,
J. D.
,
2009
, “
Vascular Mechanics, Mechanobiology, and Remodeling
,”
J. Mech. Med. Biol.
,
9
(
2
), pp.
243
257
.10.1142/S021951940900295X
51.
Cheng
,
J. K.
, and
Wagenseil
,
J. E.
,
2012
, “
Extracellular Matrix and the Mechanics of Large Artery Development
,”
Biomech Model Mechanobiol.
,
11
(
8
), pp.
1169
1186
.10.1007/s10237-012-0405-8
52.
Gerthoffer
,
W. T.
,
2007
, “
Mechanisms of Vascular Smooth Muscle Cell Migration
,”
Circul. Res.
,
100
(
5
), pp.
607
621
.10.1161/01.RES.0000258492.96097.47
53.
Zhang
,
B. C.
,
Zhou
,
Z. W.
,
Li
,
X. K.
, and
Xu
,
Y. W.
,
2011
, “
PI-3K/AKT Signal Pathway Modulates Vascular Smooth Muscle Cells Migration Under Cyclic Mechanical Strain
,”
VASA. Zeitschrift fur Gefasskrankheiten
,
40
(
2
), pp.
109
116
.10.1024/0301-1526/a000080
54.
Serruys
,
P. W.
,
Degertekin
,
M.
,
Tanabe
,
K.
,
Russell
,
M. E.
,
Guagliumi
,
G.
,
Webb
,
J.
,
Hamburger
,
J.
,
Rutsch
,
W.
,
Kaiser
,
C.
,
Whitbourn
,
R.
,
Camenzind
,
E.
,
Meredith
,
I.
,
Reeves
,
F.
,
Nienaber
,
C.
,
Benit
,
E.
,
Disco
,
C.
,
Koglin
,
J.
, and
Colombo
,
A.
,
2004
, “
Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting Stents: Serial Intravascular Ultrasound Analysis From the TAXUS II Trial
,”
Circulation
,
109
(
5
), pp.
627
633
.10.1161/01.CIR.0000112566.87022.32
55.
Poon
,
M.
,
Marx
,
S. O.
,
Gallo
,
R.
,
Badimon
,
J. J.
,
Taubman
,
M. B.
, and
Marks
,
A. R.
,
1996
, “
Rapamycin Inhibits Vascular Smooth Muscle Cell Migration
,”
J. Clin. Invest.
,
98
(
10
), pp.
2277
2283
.10.1172/JCI119038
56.
Burke
,
S. E.
,
Kuntz
,
R. E.
, and
Schwartz
,
L. B.
,
2006
, “
Zotarolimus (ABT-578) Eluting Stents
,”
Adv. Drug Del. Rev.
,
58
(
3
), pp.
437
446
.10.1016/j.addr.2006.01.021
57.
Odahara
,
T. M. H.
, and
Chiba
,
A.
,
2008
, “
Mechanical Properties of Biomedical Co-33Cr-5Mo-0.3N Alloy at Elevated Temperatures
,”
Mater. Trans.
,
49
(
9
), pp.
1963
1969
.10.2320/matertrans.MAW200816
You do not currently have access to this content.