As endovascular treatment of abdominal aortic aneurysms (AAAs) gains popularity, it is becoming possible to treat certain challenging aneurysmal anatomies with endografts relying on suprarenal fixation. In such anatomies, the bare struts of the device may be placed across the renal artery ostia, causing partial obstruction to renal artery blood flow. Computational fluid dynamics (CFD) was used to simulate blood flow from the aorta to the renal arteries, utilizing patient-specific boundary conditions, in three patient models and calculate the degree of shear-based blood damage (hemolysis). We used contrast-enhanced computed tomography angiography (CTA) data from three AAA patients who were treated with a novel endograft to build patient-specific models. For each of the three patients, we constructed a baseline model and endoframe model. The baseline model was a direct representation of the patient’s 30-day post-operative CTA data. This model was then altered to create the endoframe model, which included a ring of metallic struts across the renal artery ostia. CFD was used to simulate blood flow, utilizing patient-specific boundary conditions. Pressures, flows, shear stresses, and the normalized index of hemolysis (NIH) were quantified for all patients. The overall differences between the baseline and endoframe models for all three patients were minimal, as measured though pressure, volumetric flow, velocity, and shear stress. The average NIH across the three baseline and endoframe models was 0.002 and 0.004, respectively. Results of CFD modeling show that the overall disturbance to flow caused by the presence of the endoframe struts is minimal. The magnitude of the NIH in all models was well below the accepted design and safety threshold for implantable medical devices that interact with blood flow.

References

References
1.
Vallabhaneni
,
S. R.
, and
Harris
,
P. L.
, 2001, “
Lessons Learnt from the EUROSTAR Registry on Endovascular Repair of Abdominal Aortic Aneurysm Repair
,”
Eur. J. Radiol
,
39
(
1
), pp.
34
41
.
2.
Greenhalgh
,
R. M.
, 2004, “
Comparison of Endovascular Aneurysm Repair with Open Repair in Patients with Abdominal Aortic Aneurysm (EVAR Trial 1), 30-day Operative Mortality Results: Randomised Controlled Trial
,”
Lancet
,
364
(
9437
), pp.
843
848
.
3.
Carpenter
,
J. P.
, Baum, R. A., Barker, C. F., Golden, M. A., Mitchell, M. E., Velazquez, O. C., and Fairman, R. M., 2001, “
Impact of Exclusion Criteria on Patient Selection for Endovascular Abdominal Aortic Aneurysm Repair
,”
J. Vasc. Surg.
,
34
(
6
), pp.
1050
1054
.
4.
Wever
,
J. J.
, de Nie, A. J., Blankensteijn, J. D., Broeders, I. A. M. J.,Mali, W. P. Th. M., and Eikelboom, B. C., 2000, “
Dilatation of the Proximal Neck of Infrarenal Aortic Aneurysms after Endovascular AAA Repair
,”
Eur. J. Vasc. Endovasc. Surg.
,
19
(
2
), pp.
197
201
.
5.
Walsh
,
S. R.
, Boyle, J. R., Lynch, A. G.,Sadat, U., Carpenter, J. P., Tang, T. Y., and Gaunt, M. E., 2008, “
Suprarenal Endograft Fixation and Medium-Term Renal Function: Systematic Review and Meta-Analysis
,”
J. Vasc. Surg.
,
47
(
6
), pp.
1364
1370
.
6.
Wilson
,
W.
, Wang, K., Dutton, R., and Taylor, C., 2001, “
A Software Framework for Creating Patient Specific Geometric Models from Medical Imaging Data for Simulation Based Medical Planning of Vascular Surgery
,”
Medical Image Computing and Computer-Assisted Intervention—MICCAI 2001
,
Springer
,
Berlin
, pp.
449
456
.
7.
Les
,
A.
, Shadden, S., Figueroa, C., Park, J., Tedesco, M., Herfkens, R., Dalman, R., and Taylor, C., 2010, “
Quantification of Hemodynamics in Abdominal Aortic Aneurysms During Rest and Exercise Using Magnetic Resonance Imaging and Computational Fluid Dynamics
,”
Ann. Biomed. Eng.
,
38
(
4
), pp.
1288
1313
.
8.
Lam
,
T. K.
, and
Leung
,
D. T.
, 1988, “
More on Simplified Calculation of Body-Surface Area
,”
New Engl. J. Med.
,
318
(
17
), pp.
1130
1130
.
9.
Toy
,
S. M.
,
Melbin
,
J.
, and
Noordergraaf
,
A.
, 1985, “
Reduced Models of Arterial Systems
,”
IEEE Trans. Biomed. Eng.
,
32
(
2
), pp.
174
176
.
10.
Kim
,
H. J.
, Figueroa, C. A., Hughes, T. J. R., Jansen, K. E., and Taylor, C. A., 2009, “
Augmented Lagrangian Method for Constraining the Shape of Velocity Profiles at Outlet Boundaries for Three-Dimensional Finite Element Simulations of Blood Flow
,”
Comput. Methods Appl. Mech. Eng.
,
198
(
45-46
), pp.
3551
3566
.
11.
Bludszuweit
,
C.
, 1995, “
Model for a General Mechanical Blood Damage Prediction
,”
Artif, Organs
,
19
(
7
), pp.
583
589
.
12.
Garon
,
A.
, and
Farinas
,
M. I.
, 2004, “
Fast Three-Dimensional Numerical Hemolysis Approximation
,”
Artif. Organs
,
28
(
11
), pp.
1016
1025
.
13.
Yeleswarapu
,
K. K.
, Antaki, J. F., Kameneva, M. V., and Rajagopal, K. R., 1995, “
A Mathematical Model for Shear-Induced Hemolysis
,”
Artif. Organs
,
19
(
7
), pp.
576
582
.
14.
Arora
,
D.
,
Behr
,
M.
, and
Pasquali
,
M.
, 2004, “
A Tensor-Based Measure for Estimating Blood Damage
,”
Artif. Organs
,
28
(
11
), pp.
1002
1015
.
15.
Bluestein
,
M.
, and
Mockros
,
L.
, 1969, “
Hemolytic Effects of Energy Dissipation in Flowing Blood
,”
Med. Biol. Eng.
7
(
1
), pp.
1
16
.
16.
Giersiepen
,
M.
, Wurzinger, L. J., Opitz, R., and Reul, H., 1990, “
Estimation of Shear Stress-Related Blood Damage in Heart Valve Prostheses—in vitro Comparison of 25 Aortic Valves
,”
Int. J. Artif. Organs
,
13
(
5
), pp.
300
306
.
17.
Bax
,
L.
, Bakker, C. J., Klein, W. M., Blanken, N., Beutler, J. J., and Mali, W. P., 2005, “
Renal Blood Flow Measurements with Use of Phase-Contrast Magnetic Resonance Imaging: Normal Values and Reproducibility
,”
J. Vasc. Interv. Radiol.
,
16
(
6
), pp.
807
814
.
18.
Nosé
,
Y.
, 1998, “
Design and Development Strategy for the Rotary Blood Pump
,”
Artif. Organs
,
22
(
6
), pp.
438
446
.
19.
Paul
,
R.
, Apel, J., Klaus, S., Schügner, F., Schwindke, P., and Reul, H., 2003, “
Shear Stress Related Blood Damage in Laminar Couette Flow
,”
Artif. Organs
,
27
(
6
), pp.
517
529
.
20.
Desgranges
,
P.
, Hutin, E., Kedzia, C., Allaire, E., and Becquemin, J. P., 1997, “
Aortic Stents Covering the Renal Arteries Ostia: An Animal Study
,”
J. Vasc. Interv. Radiol.
,
8
(
1, Part 1
), pp.
77
82
.
21.
Birch
,
P. C.
, Start, R. D., Whitbread, T., Palmer, I., Gaines, P. A., and Beard, J. D., 1999, “
The Effects of Crossing Porcine Renal Artery Ostia with Various Endovascular Stents
,”
Eur. J. Vasc. Endovasc. Surg.
,
17
(
3
), pp.
185
190
.
You do not currently have access to this content.