The technique of crossing the limbs of bifurcated modular stent grafts for endovascular aneurysm repair (EVAR) is often employed in the face of splayed aortic bifurcations to facilitate cannulation and prevent device kinking. However, little has been reported about the implications of cross-limb EVAR, especially in comparison to conventional EVAR. Previous computational fluid dynamics studies of conventional EVAR grafts have mostly utilized simplified planar stent graft geometries. We herein examined the differences between conventional and cross-limb EVAR by comparing their hemodynamic flow fields (i.e., in the “direct” and “cross” configurations, respectively). We also added a “planar” configuration, which is commonly found in the literature, to identify how well this configuration compares to out-of-plane stent graft configurations from a hemodynamic perspective. A representative patient’s cross-limb stent graft geometry was segmented using computed tomography imaging in Mimics software. The cross-limb graft geometry was used to build its direct and planar counterparts in SolidWorks. Physiologic velocity and mass flow boundary conditions and blood properties were implemented for steady-state and pulsatile transient simulations in ANSYS CFX. Displacement forces, wall shear stress (WSS), and oscillatory shear index (OSI) were all comparable between the direct and cross configurations, whereas the planar geometry yielded very different predictions of hemodynamics compared to the out-of-plane stent graft configurations, particularly for displacement forces. This single-patient study suggests that the short-term hemodynamics involved in crossing the limbs is as safe as conventional EVAR. Higher helicity and improved WSS distribution of the cross-limb configuration suggest improved flow-related thrombosis resistance in the short term. However, there may be long-term fatigue implications to stent graft use in the cross configuration when compared to the direct configuration.

References

References
1.
Overbeck
,
K.
,
Jackson
,
R.
, and
Rose
,
J.
,
2005
, “
Complications and Bail-Out Situations During AAA Endovascular Repair
,”
Tech. Vascular Interventional Radiol.
,
8
(
1 Spec. Iss.
), pp.
22
29
.10.1053/j.tvir.2005.03.013
2.
Myers
,
K.
,
Devine
,
T.
,
Barras
,
C.
, and
Self
,
G.
,
2001
, “
Endoluminal Versus Open Repair for Abdominal Aortic Aneurysms
,” http://www.fac.org.ar/scvc/llave/interven/ myers/myersi.htm
3.
Dang
,
W.
,
Kilian
,
M.
,
Peterson
,
M. D.
, and
Cinã
,
C.
,
2010
, “
Relationship Between Access Side Used to Deliver the Main Body of Bifurcated Prostheses for Endovascular Aneurysm Repair and Speed of Cannulation of the Contralateral Limb
,”
J. Vascular Surg.
,
51
(
1
), pp.
33
37
.10.1016/j.jvs.2009.08.003
4.
Cronenwett
,
J. L.
, and
Johnston
,
W.
,
2010
,
Rutherford’s Vascular Surgery
,
7th
ed.
Saunders
,
Philadelphia, PA
.
5.
Ramaiah
,
V. G.
,
Thompson
,
C. S.
,
Shafique
,
S.
,
Rodriguez
,
J. A.
,
Ravi
,
R.
,
DiMugno
,
L.
, and
Diethrich
,
E. B.
,
2002
, “
Crossing the Limbs: A Useful Adjunct for Successful Deployment of the AneuRx Stent-Graft
,”
J. Endovascular Therapy
,
9
(
5
), pp.
583
586
.10.1583/1545-1550(2002)009<0583:CTLAUA>2.0.CO;2
6.
Chuter
,
T. A. M.
,
2009
, “
Durability of Endovascular Infrarenal Aneurysm Repair: When Does Late Failure Occur and Why?
,”
Seminars Vascular Surg.
,
22
(
2
), pp.
102
110
.10.1053/j.semvascsurg.2009.04.008
7.
Kleinstreuer
,
C.
,
Li
,
Z.
, and
Farber
,
M. A.
,
2007
, “
Fluid-Structure Interaction Analyses of Stented Abdominal Aortic Aneurysms
,”
Annu. Rev. Biomed. Eng.
,
9
, pp.
169
204
.10.1146/annurev.bioeng.9.060906.151853
8.
Howell
,
B. A.
,
Kim
,
T.
,
Cheer
,
A.
,
Dwyer
,
H.
,
Saloner
,
D.
, and
Chuter
,
T. A. M.
,
2007
, “
Computational Fluid Dynamics Within Bifurcated Abdominal Aortic Stent-Grafts
,
J. Endovascular Therapy
,
14
(
2
), pp.
138
143
.10.1583/1545-1550(2007)14[138:CFDWBA]2.0.CO;2
9.
Bosman
,
W. M. P. F.
,
van der Steenhoven
,
T. J.
,
Suárez
,
D. R.
,
Hinnen
,
J. W.
,
Valstar
,
E. R.
, and
Hamming
,
J. F.
,
2010
, “
The Proximal Fixation Strength of Modern EVAR Grafts in a Short Aneurysm Neck. An In Vitro Study
,”
Eur. J. Vascular Endovascular Surg.
,
39
(
2
), pp.
187
192
.10.1016/j.ejvs.2009.10.019
10.
Finol
,
E. A.
,
Keyhani
,
K.
, and
Amon
,
C. H.
,
2003
, “
The Effect of Asymmetry in Abdominal Aortic Aneurysms Under Physiologically Realistic Pulsatile Flow Conditions
,”
ASME J. Biomech. Eng.
,
125
(
2
), pp.
207
217
.10.1115/1.1543991
11.
Liffman
,
K.
,
Lawrence-Brown
,
M. M. D.
,
Semmens
,
J. B.
,
Bui
,
A.
,
Rudman
,
M.
, and
Hartley
,
D. E.
,
2001
, “
Analytical Modeling and Numerical Simulation of Forces in an Endoluminal Graft
,”
J. Endovascular Therapy
,
8
(
4
), pp.
358
371
.10.1583/1545-1550(2001)008<0358:AMANSO>2.0.CO;2
12.
Morris
,
L. G.
,
Delassus
,
P.
,
Walsh
,
M. T.
, and
McGloughlin
,
T. M.
,
2004
, “
A Mathematical Model to Predict the In Vivo Pulsatile Drag Forces Acting on Bifurcated Stent Grafts Used in Endovascular Treatment of Abdominal Aortic Aneurysms (AAA)
,”
J. Biomech.
,
37
(
7
), pp.
1087
1095
.10.1016/j.jbiomech.2003.11.014
13.
Martufi
,
G.
,
Di Martino
,
E. S.
,
Amon
,
C. H.
,
Muluk
,
S. C.
, and
Finol
,
E. A.
,
2009
, “
Three-Dimensional Geometrical Characterization of Abdominal Aortic Aneurysms: Image-Based Wall Thickness Distribution
,”
ASME J. Biomech. Eng.
,
131
(
6
), p.
061015
.10.1115/1.3127256
14.
Scotti
,
C. M.
,
Jimenez
,
J.
,
Muluk
,
S. C.
, and
Finol
,
E. A.
,
2008
, “
Wall Stress and Flow Dynamics in Abdominal Aortic Aneurysms: Finite Element Analysis vs. Fluid-Structure Interaction
,”
Comput. Methods Biomech. Biomed. Eng.
,
11
, pp.
301
322
.10.1080/10255840701827412
15.
Morris
,
L. G.
,
Delassus
,
P.
,
Grace
,
P.
,
Wallis
,
F.
,
Walsh
,
M. T.
, and
McGloughlin
,
T. M.
,
2006
, “
Effects of Flat, Parabolic and Realistic Steady Flow Inlet Profiles on Idealised and Realistic Stent Graft Fits Through Abdominal Aortic Aneurysms (AAA)
,”
Med. Eng. Phys.
,
28
(
1
), pp.
19
26
.10.1016/j.medengphy.2005.04.012
16.
Li
,
Z.
, and
Kleinstreuer
,
C.
,
2006
, “
Analysis of Biomechanical Factors Affecting Stent-Graft Migration in an Abdominal Aortic Aneurysm Model
,”
J. Biomech.
,
39
(
12
), pp.
2264
2273
.10.1016/j.jbiomech.2005.07.010
17.
Molony
,
D. S.
,
Kavanagh
,
E. G.
,
Madhavan
,
P.
,
Walsh
,
M. T.
, and
McGloughlin
,
T. M.
,
2010
, “
A Computational Study of the Magnitude and Direction of Migration Forces in Patient-Specific Abdominal Aortic Aneurysm Stent-Grafts
,”
Eur. J. Vascular Endovascular Surg.
,
40
(
3
), pp.
332
339
.10.1016/j.ejvs.2010.06.001
18.
Hobo
,
R.
,
Sybrandy
,
J. E. M.
,
Harris
,
P. L.
,
Buth
,
J.
, and
Collaborators
,
E.
,
2008
, “
Endovascular Repair of Abdominal Aortic Aneurysms With Concomitant Common Iliac Artery Aneurysm: Outcome Analysis of the EUROSTAR Experience
,”
J. Endovascular Therapy
,
15
(
1
), pp.
12
22
.10.1583/07-2217.1
19.
Mestres
,
G.
,
Maeso
,
J.
,
Fernandez
,
V.
,
Allegue
,
N.
,
Constenla
,
I.
, and
Matas
,
M.
,
2009
, “
Incidence and Evolution of Mural Thrombus in Abdominal Aortic Endografts
,”
Ann. Vascular Surg.
,
23
(
5
), pp.
627
633
.10.1016/j.avsg.2008.10.011
20.
Maldonado
,
T.
,
Ranson
,
M.
,
Rockman
,
C.
,
Pua
,
B.
,
Cayne
,
N.
,
Jacobowitz
,
G.
, and
Adelman
,
M.
,
2007
, “
Decreased Ischemic Complications After Endovascular Aortic Aneurysm Repair With Newer Devices
,”
Vascular Endovascular Surg.
,
41
(
3
), pp.
192
199
.10.1177/1538574407300915
21.
Caro
,
C. G.
,
Cheshire
,
N. J.
, and
Watkins
,
N.
,
2005
, “
Preliminary Comparative Study of Small Amplitude Helical and Conventional ePTFE Arteriovenous Shunts in Pigs
,”
J. R. Soc. Interface
,
2
(
3
), pp.
261
266
.10.1098/rsif.2005.0044
22.
Ku
,
D. N.
,
Giddens
,
D. P.
,
Zarins
,
C. K.
, and
Glagov
,
S.
,
1985
, “
Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation—Positive Correlation Between Plaque Location and Low and Oscillating Shear-Stress
,”
Arteriosclerosis
,
5
(
3
), pp.
293
302
.10.1161/01.ATV.5.3.293
23.
Wootton
,
D. M.
, and
Ku
,
D. N.
,
1999
, “
Fluid Mechanics of Vascular Systems, Diseases, and Thrombosis
,”
Annu. Rev. Biomed. Eng.
,
1
, pp.
299
329
.10.1146/annurev.bioeng.1.1.299
24.
Stonebridge
,
P. A.
, and
Brophy
,
C. M.
,
1991
, “
Spiral Laminar Flow in Arteries?
,”
Lancet
,
338
(
8779
), pp.
1360
1361
.10.1016/0140-6736(91)92238-W
25.
Kilner
,
P. J.
,
Yang
,
G. Z.
,
Mohiaddin
,
R. H.
,
Firmin
,
D. N.
, and
Longmore
,
D. B.
,
1993
, “
Helical and Retrograde Secondary Flow Patterns in the Aortic-Arch Studied by 3-Directional Magnetic-Resonance Velocity Mapping
,”
Circulation
,
88
(
5
), pp.
2235
2247
.10.1161/01.CIR.88.5.2235
26.
Taylor
,
C. A.
, and
Figueroa
,
C. A.
,
2009
, “
Patient-Specific Modeling of Cardiovascular Mechanics
,”
Annu. Rev. Biomed. Eng.
,
11
, pp.
109
134
.10.1146/annurev.bioeng.10.061807.160521
27.
Di Martino
,
E.
,
Guadagni
,
G.
,
Fumero
,
A.
,
Ballerini
,
G.
,
Spirito
,
R.
,
Biglioli
,
P.
, and
Redaelli
,
A.
,
2001
, “
Fluid-Structure Interaction Within Realistic Three-Dimensional Models of the Aneurysmatic Aorta as a Guidance to Assess the Risk of Rupture of the Aneurysm
,”
Med. Eng. Phys.
,
23
(
9
), pp.
647
655
.10.1016/S1350-4533(01)00093-5
28.
Vignon-Clementel
,
I. E.
,
Figueroa
,
C. A.
,
Jansen
,
K. E.
, and
Taylor
,
C. A.
,
2006
, “
Outflow Boundary Conditions for Three-Dimensional Finite Element Modeling of Blood Flow and Pressure in Arteries
,”
Comput. Methods Appl. Mech. Eng.
,
195
(
29–32
), pp.
3776
3796
.10.1016/j.cma.2005.04.014
29.
Lee
,
K. E.
,
Lee
,
J. S.
, and
Yoo
,
J. Y.
,
2011
, “
A Numerical Study on Steady Flow in Helically Sinuous Vascular Prostheses
,”
Med. Eng. Phys.
,
33
(
1
), pp.
38
46
.10.1016/j.medengphy.2010.09.005
30.
Corbett
,
T. J.
,
Callanan
,
A.
, and
McGloughlin
,
T. M.
,
2011
. “
In Vitro Measurement of the Axial Migration Force on the Proximal End of a Bifurcated Abdominal Aortic Aneurysm Stent-Graft Model
,”
Proc. Inst. Mech. Eng. Part H: J. Eng. Med.
,
225
(
4
), pp.
401
409
.10.1177/09544119JEIM748
31.
Segalova
,
P. A.
,
Xiong
,
G.
,
Rao
,
K. T. V.
,
Zarins
,
C. K.
, and
Taylor
,
C. A.
,
2011
, “
Evaluating Design of Abdominal Aortic Aneurysm Endografts in a Patient-Specific Model Using Computational Fluid Dynamics
,”
ASME J. Med. Devices
,
5
(
4
), p.
041005
. Available at http://digitalcommons.olin.edu/alumni_pubs/2/10.1115/1.4005228
32.
Figueroa
,
C. A.
,
Taylor
,
C. A.
,
Yeh
,
V.
,
Chiou
,
A. J.
,
Gorrepati
,
M. L.
, and
Zarins
,
C. K.
,
2010
, “
Preliminary 3D Computational Analysis of the Relationship Between Aortic Displacement Force and Direction of Endograft Movement
,”
J. Vascular Surg.
,
51
(
6
), pp.
1488
1497
.10.1016/j.jvs.2010.01.058
33.
Figueroa
,
C. A.
,
Taylor
,
C. A.
,
Yeh
,
V.
,
Chiou
,
A. J.
, and
Zarins
,
C. K.
,
2009
, “
Effect of Curvature on Displacement Forces Acting on Aortic Endografts: A 3-Dimensional Computational Analysis
,”
J. Endovascular Therapy
,
16
(
3
), pp.
284
294
.10.1583/08-2667.1
34.
Myers
,
J. G.
,
Moore
,
J. A.
,
Ojha
,
M.
,
Johnston
,
K. W.
, and
Ethier
,
C. R.
,
2001
, “
Factors Influencing Blood Flow Patterns in the Human Right Coronary Artery
,”
Ann. Biomed. Eng.
,
29
, pp.
109
120
.10.1114/1.1349703
35.
Wu
,
I. H.
,
Liang
,
P. C.
,
Huang
,
S. C.
,
Chi
,
N. S.
,
Lin
,
F. Y.
, and
Wang
,
S. S.
,
2009
.
“The Significance of Endograft Geometry on the Incidence of Intraprosthetic Thrombus Deposits After Abdominal Endovascular Grafting
,”
Eur. J. Vascular Endovascular Surg.
,
38
(
6
), pp.
741
747
.10.1016/j.ejvs.2009.09.004
36.
Maleux
,
G.
,
Koolen
,
M.
,
Heye
,
S.
,
Heremans
,
B.
, and
Nevelsteen
,
A.
,
2008
, “
Mural Thrombotic Deposits in Abdominal Aortic Endografts are Common and Do Not Require Additional Treatment at Short-Term and Midterm Follow-Up
,”
J. Vascular Interventional Radiol.
,
19
(
11
), pp.
1558
1562
.10.1016/j.jvir.2008.08.007
37.
Huijbregts
,
H. J. T. A. M.
,
Blankestijn
,
P. J.
,
Caro
,
C. G.
,
Cheshire
,
N. J. W.
,
Hoedt
,
M. T. C.
,
Tutein Nolthenius
,
R. P.
, and
Moll
,
F. L.
,
2007
, “
A Helical PTFE Arteriovenous Access Graft to Swirl Flow Across the Distal Anastomosis: Results of a Preliminary Clinical Study
.”
Eur. J. Vascular Endovascular Surg.
,
33
(
4
), pp.
472
475
.10.1016/j.ejvs.2006.10.028
38.
Molony
,
D. S.
,
Callanan
,
A.
,
Morris
,
L. G.
,
Doyle
,
B. J.
,
Walsh
,
M. T.
, and
McGloughlin
,
T. M.
,
2008
, “
Geometrical Enhancements for Abdominal Aortic Stent-Grafts
,”
J. Endovascular Therapy
,
15
(
5
), pp.
518
529
.10.1583/08-2388.1
You do not currently have access to this content.