While many congenital heart defects can be treated without significant long term sequelae, some achieve successful palliation as their definitive endpoints. The single-ventricle defect is one such defect and leaves the child with only one operational ventricle, requiring the systemic and the pulmonary circulations to be placed in series through several operations performed during early childhood. Numerical simulations may be used to investigate these hemodynamic conditions and their relation to post-operative sequelae; however, they rely heavily on boundary condition prescription. In this study, we investigate the impact of hemodynamic input data uncertainties on simulation results. Imaged-based patient-specific models of the multi-branched pulmonary arteries and superior vena cava were built for five cavopulmonary connection (i.e. Glenn) patients. Magnetic resonance imaging and catheterization data were acquired for each patient prior to their Fontan surgery. Inflow and outflow boundary conditions were constructed to match available clinical data and resulted in the development of a framework to incorporate these types of clinical data into patient-specific simulations. Three-dimensional computational fluid dynamics simulations were run and hemodynamic indicators were computed. Power loss was low (and efficiency very high) and a linear correlation was found between power loss and cardiac index among the five patients. Other indicators such as low wall shear stress were considered to better characterize these patients. Flow was complex and oscillatory near the anastomosis, and laminar in the smaller branches. While common trends were seen among patients, results showed differences among patients, especially in the 3D maps, strengthening the importance of patient-specific simulations. A sensitivity analysis was performed to investigate the impact of input data (clinical and modeling) to construct boundary conditions on several indicators. Overall, the sensitivity of the output indicators to the input data was small but non-negligible. The sensitivity of commonly used hemodynamic indicators to compare patients is discussed in this context. Power efficiency was much more sensitive to pressure variation than power loss. To increase the precision of such indicators, mean flow split between right and left lungs needs to be measured with more accuracy with higher priority than refining the model of how the flow is distributed on average among the smaller branches. Although flow split imprecision seemed reasonable in terms of patient comparison, this study suggests that the common practice of imposing a right pulmonary artery/left pulmonary artery flow split of when performing patient specific simulations should be avoided. This study constitutes a first step towards understanding the hemodynamic differences between pre- and post Fontan surgery, predicting these differences, and evaluating surgical outcomes based on preoperative data.
Skip Nav Destination
Article navigation
November 2011
Research Papers
Three-Dimensional Simulations in Glenn Patients: Clinically Based Boundary Conditions, Hemodynamic Results and Sensitivity to Input Data
G. Troianowski,
G. Troianowski
Institute for Computational and Mathematical Engineering,
Stanford University
, Stanford, CA 94305
Search for other works by this author on:
C. A. Taylor,
C. A. Taylor
Bioengineering Department, Stanford University, Stanford, CA 94305; Surgery Department,
Stanford University
, Stanford, CA 94305
Search for other works by this author on:
J. A. Feinstein,
J. A. Feinstein
Bioengineering Department, Stanford University, Stanford, CA 94305; Pediatrics Department,
Stanford University
, Stanford, CA 94305
Search for other works by this author on:
I. E. Vignon-Clementel
I. E. Vignon-Clementel
INRIA Paris-Rocquencourt, BP 105, 78153 Le Chesnay Cedex,
France
Search for other works by this author on:
G. Troianowski
Institute for Computational and Mathematical Engineering,
Stanford University
, Stanford, CA 94305
C. A. Taylor
Bioengineering Department, Stanford University, Stanford, CA 94305; Surgery Department,
Stanford University
, Stanford, CA 94305
J. A. Feinstein
Bioengineering Department, Stanford University, Stanford, CA 94305; Pediatrics Department,
Stanford University
, Stanford, CA 94305
I. E. Vignon-Clementel
INRIA Paris-Rocquencourt, BP 105, 78153 Le Chesnay Cedex,
France
J Biomech Eng. Nov 2011, 133(11): 111006 (16 pages)
Published Online: December 1, 2011
Article history
Received:
January 28, 2011
Revised:
August 17, 2011
Online:
December 1, 2011
Published:
December 1, 2011
Citation
Troianowski, G., Taylor, C. A., Feinstein, J. A., and Vignon-Clementel, I. E. (December 1, 2011). "Three-Dimensional Simulations in Glenn Patients: Clinically Based Boundary Conditions, Hemodynamic Results and Sensitivity to Input Data." ASME. J Biomech Eng. November 2011; 133(11): 111006. https://doi.org/10.1115/1.4005377
Download citation file:
Get Email Alerts
Estimation of Joint Kinetics During Manual Material Handling Using Inertial Motion Capture: A Follow-Up Study
J Biomech Eng (February 2025)
Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues
J Biomech Eng (February 2025)
Eyelid Motion Tracking During Blinking Using High-Speed Imaging and Digital Image Correlation
J Biomech Eng (January 2025)
Related Articles
Optimization of Inflow Waveform Phase-Difference for Minimized Total Cavopulmonary Power Loss
J Biomech Eng (March,2010)
Neonatal Aortic Arch Hemodynamics and Perfusion During Cardiopulmonary Bypass
J Biomech Eng (December,2008)
Related Proceedings Papers
Related Chapters
Micromachined 1-3 Composite Single Element Transducers
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
Introduction
Modified Detrended Fluctuation Analysis (mDFA)