The glenoid labrum is an integral component of the glenohumeral capsule’s insertion into the glenoid, and changes in labrum geometry and mechanical properties may lead to the development of glenohumeral joint pathology. The objective of this research was to determine the effect that changes in labrum thickness and modulus have on strains in the labrum and glenohumeral capsule during a simulated physical examination for anterior instability. A labrum was incorporated into a validated, subject-specific finite element model of the glenohumeral joint, and experimental kinematics were applied simulating application of an anterior load at 0 deg, 30 deg, and 60 deg of external rotation and 60 deg of glenohumeral abduction. The radial thickness of the labrum was varied to simulate thinning tissue, and the tensile modulus of the labrum was varied to simulate degenerating tissue. At 60 deg of external rotation, a thinning labrum increased the average and peak strains in the labrum, particularly in the labrum regions of the axillary pouch (increased 10.5% average strain) and anterior band (increased 7.5% average strain). These results suggest a cause-and-effect relationship between age-related decreases in labrum thickness and increases in labrum pathology. A degenerating labrum also increased the average and peak strains in the labrum, particularly in the labrum regions of the axillary pouch (increased 15.5% strain) and anterior band (increased 10.4% strain). This supports the concept that age-related labrum pathology may result from tissue degeneration. This work suggests that a shift in capsule reparative techniques may be needed in order to include the labrum, especially as activity levels in the aging population continue to increase. In the future validated, finite element models of the glenohumeral joint can be used to explore the efficacy of new repair techniques for glenoid labrum pathology.
Skip Nav Destination
e-mail: drury.nick@gmail.com
e-mail: u0241427@utah.edu
e-mail: jeff.weiss@utah.edu
e-mail: mcmahonp@upmc.edu
e-mail: genesis1@pitt.edu
Article navigation
December 2010
Research Papers
The Impact of Glenoid Labrum Thickness and Modulus on Labrum and Glenohumeral Capsule Function
Nicholas J. Drury,
Nicholas J. Drury
Department of Bioengineering,
e-mail: drury.nick@gmail.com
University of Pittsburgh
, Pittsburgh, PA 15219
Search for other works by this author on:
Benjamin J. Ellis,
Benjamin J. Ellis
Department of Bioengineering,
e-mail: u0241427@utah.edu
University of Utah
, Salt Lake City, UT 84112
Search for other works by this author on:
Jeffrey A. Weiss,
Jeffrey A. Weiss
Department of Bioengineering,
e-mail: jeff.weiss@utah.edu
University of Utah
, Salt Lake City, UT 84112
Search for other works by this author on:
Patrick J. McMahon,
Patrick J. McMahon
Department of Bioengineering,
e-mail: mcmahonp@upmc.edu
University of Pittsburgh
, Pittsburgh, PA 15219
Search for other works by this author on:
Richard E. Debski
Richard E. Debski
Department of Bioengineering,
e-mail: genesis1@pitt.edu
University of Pittsburgh
, Pittsburgh, PA 15219
Search for other works by this author on:
Nicholas J. Drury
Department of Bioengineering,
University of Pittsburgh
, Pittsburgh, PA 15219e-mail: drury.nick@gmail.com
Benjamin J. Ellis
Department of Bioengineering,
University of Utah
, Salt Lake City, UT 84112e-mail: u0241427@utah.edu
Jeffrey A. Weiss
Department of Bioengineering,
University of Utah
, Salt Lake City, UT 84112e-mail: jeff.weiss@utah.edu
Patrick J. McMahon
Department of Bioengineering,
University of Pittsburgh
, Pittsburgh, PA 15219e-mail: mcmahonp@upmc.edu
Richard E. Debski
Department of Bioengineering,
University of Pittsburgh
, Pittsburgh, PA 15219e-mail: genesis1@pitt.edu
J Biomech Eng. Dec 2010, 132(12): 121003 (7 pages)
Published Online: November 1, 2010
Article history
Received:
March 31, 2010
Revised:
September 14, 2010
Posted:
September 27, 2010
Published:
November 1, 2010
Online:
November 1, 2010
Citation
Drury, N. J., Ellis, B. J., Weiss, J. A., McMahon, P. J., and Debski, R. E. (November 1, 2010). "The Impact of Glenoid Labrum Thickness and Modulus on Labrum and Glenohumeral Capsule Function." ASME. J Biomech Eng. December 2010; 132(12): 121003. https://doi.org/10.1115/1.4002622
Download citation file:
Get Email Alerts
Effect of Internal Mechanical Environment of Porous Scaffolds on Mechano-driven Bone Ingrowth: A Numerical Study
J Biomech Eng (September 2023)
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
J Biomech Eng (September 2023)
Related Articles
Computer Simulation of Female Urinary Incontinence
J. Med. Devices (June,2008)
Porohyperelastic Finite Element Modeling of Abdominal Aortic Aneurysms
J Biomech Eng (October,2010)
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Measurements of the Static Friction Coefficient Between Bone and Muscle Tissues
J Biomech Eng (August,2010)
Related Proceedings Papers
Related Chapters
Data Tabulations
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Conclusion & executive summary
Photodynamic Therapy Mediated by Fullerenes and their Derivatives