Quantification of bone strain can be used to better understand fracture risk, bone healing, and bone turnover. The objective of this work was to develop and validate an intensity matching image registration method to accurately measure and spatially resolve strain in vertebrae using μCT imaging. A strain quantification method was developed that used two sequential μCT scans, taken in loaded and unloaded configurations. The image correlation algorithm implemented was a multiresolution intensity matching deformable registration that found a series of affine mapping between the unloaded and loaded scans. Once the registration was completed, the displacement field and strain field were calculated from the mappings obtained. Validation was done in two distinct ways: the first was to look at how well the method could quantify zero strain; the second was to look at how the method was able to reproduce a known applied strain field. Analytically defined strain fields that linearly varied in space and strain fields resulting from finite element analysis were used to test the strain measurement algorithm. The deformable registration method showed very good agreement with all cases imposed, establishing a detection limit of 0.0004 strain and displaying agreement with the imposed strain cases (average R2=0.96). The deformable registration routine developed was able to accurately measure both strain and displacement fields in whole rat vertebrae. A rigorous validation of any strain measurement method is needed that reports on the ability of the routine to measure strain in a variety of strain fields with differing spatial extents, within the structure of interest.

1.
Mizrahi
,
J.
,
Silva
,
M. J.
, and
Hayes
,
W. C.
, 1992, “
Finite Element Stress Analysis of Simulated Metastatic Lesions in the Lumbar Vertebral Body
,”
J. Biomed. Eng.
0141-5425,
14
(
6
), pp.
467
475
.
2.
Roth
,
S. E.
,
Rebello
,
M. M.
, and
Kreder
,
H.
, 2004, “
Pressurization of the Metastatic Femur During Prophylactic Intramedullary Nail Fixation
,”
J. Trauma: Inj., Infect., Crit. Care
1079-6061,
57
(
2
), pp.
333
339
.
3.
Ebihara
,
H.
,
Ito
,
M.
, and
Abumi
,
K.
, 2004, “
A Biomechanical Analysis of Metastatic Vertebral Collapse of the Thoracic Spine: A Sheep Model Study
,”
Spine
0362-2436,
29
(
9
), pp.
994
999
.
4.
Perez-Quintian
,
F.
,
Lutenberg
,
A.
, and
Rebollo
,
M. A.
, 2006, “
Linear Displacement Measurement With a Grating and Speckle Pattern Illumination
,”
Appl. Opt.
0003-6935,
45
(
20
), pp.
4821
4825
.
5.
Bay
,
B. K.
, 1999, “
Measurement of Strain Distributions Within Vertebral Body Sections by Texture Correlation
,”
Spine
0362-2436,
24
(
1
), pp.
10
17
.
6.
Veress
,
A. I.
,
Weiss
,
J. A.
, and
Gullberg
,
G. T.
, 2002, “
Strain Measurement in Coronary Arteries Using Intravascular Ultrasound and Deformable Images
,”
ASME J. Biomech. Eng.
0148-0731,
124
(
6
), pp.
734
741
.
7.
Sutton
,
M. A.
,
Wong
,
A. K.
, and
Chao
,
Y. J.
, 1983, “
Enhanced-Displacement Measurement Using a Generalized Formulation for Double-Aperture Specklegrams
,”
Exp. Mech.
0014-4851,
23
(
3
), pp.
348
353
.
8.
Smith
,
T. S.
,
Bay
,
B. K.
, and
Rashid
,
M. M.
, 2002, “
Digital Volume Correlation Including Rotational Degrees of Freedom During Minimization
,”
Exp. Mech.
0014-4851,
42
(
3
), pp.
272
278
.
9.
Wang
,
C. C.
,
Deng
,
J. M.
, and
Ateshian
,
G. A.
, 2002, “
An Automated Approach for Direct Measurement of Two-Dimensional Strain Distributions Within Articular Cartilage Under Unconfined Compression
,”
ASME J. Biomech. Eng.
0148-0731,
124
(
5
), pp.
557
567
.
10.
Weiss
,
J. A.
,
Rabbitt
,
R. D.
, and
Bowden
,
A. E.
, 1998, “
Incorporation of Medical Image Data in Finte Element Models to Track Strain is Soft Tissues
,”
International Biomedical Optics Symposium
.
11.
Bay
,
B. K.
, 1995, “
Texture Correlation: A Method for the Measurement of Detailed Strain Distributions Within Trabecular Bone
,”
J. Orthop. Res.
0736-0266,
13
(
2
), pp.
258
267
.
12.
Williams
,
D. R.
,
Davidson
,
D. L.
, and
Lankford
,
J.
, 1980, “
Fatigue-Crack-Tip Plastic Strains by the Stereoimaging Technique
,”
Exp. Mech.
0014-4851,
20
(
4
), pp.
134
139
.
13.
Peters
,
W. H.
, and
Ranson
,
W. F.
, 1980, “
Digital Imaging Techniques in Stress Analysis
,”
Opt. Eng.
0091-3286,
21
(
3
), pp.
427
431
.
14.
Zauel
,
R.
,
Yeni
,
Y. N.
, and
Bay
,
B. K.
, 2006, “
Comparison of the Linear Finite Element Prediction of Deformation and Strain of Human Cancellous Bone to 3D Digital Volume Correlation Measurements
,”
ASME J. Biomech. Eng.
0148-0731,
128
(
1
), pp.
1
6
.
15.
Verhulp
,
E.
,
van Rietbergen
,
B.
, and
Huiskes
,
R.
, 2004, “
A Three-Dimensional Digital Image Correlation Technique for Strain Measurements in Microstructures
,”
J. Biomech.
0021-9290,
37
(
9
), pp.
1313
1320
.
16.
Bevill
,
G.
,
Ün
,
K.
, and
Keaveny
,
T. M.
, 2006, “
Substantial Discrepancy Between In Vitro and In Situ Behavior of Trabecular Bone
,”
52nd Annual Meeting of the Orthopaedic Research Society Transactions
, Poster No. 1788.
17.
Ibanez
,
L.
,
Schroeder
,
W.
, and
Ng
,
L.
, 2005,
The ITK Software Guide
,
Kitware Inc.
,
Bethesda, MD
, pp.
836
.
18.
Roeder
,
B. A.
,
Kokini
,
K.
, and
Robinson
,
J. P.
, 2004, “
Local, Three-Dimensional Strain Measurements Within Largely Deformed Extracellular Matrix Constructs
,”
ASME J. Biomech. Eng.
0148-0731,
126
(
6
), pp.
699
708
.
19.
Liu
,
L.
, and
Morgan
,
E. F.
, 2006, “
The Accuracy and Precision of Digital Image Correlation in Quantifying Local 3-D Strains in Trabecular Bone Depend on Trabecular Architecture
,”
5th World Congress of Biomechanics
, Abstract 5487.
20.
Sun
,
Y.
,
Pang
,
J. H.
, and
Wong
,
C. K.
, 2005, “
Finite Element Formulation for a Digital Image Correlation Method
,”
Appl. Opt.
0003-6935,
44
(
34
), pp.
7357
7363
.
21.
Phatak
,
N. S.
,
Sun
,
Q.
, and
Kim
,
S. E.
, 2007, “
Noninvasive Determination of Ligament Strain With Deformable Image Registration
,”
Ann. Biomed. Eng.
0090-6964,
35
, pp.
1175
1187
.
22.
Gilchrist
,
C. L.
,
Xia
,
J. Q.
, and
Setton
,
L. A.
, 2004, “
High-Resolution Determination of Soft Tissue Deformations Using MRI and First-Order Texture Correlation
,”
IEEE Trans. Med. Imaging
0278-0062,
23
(
5
), pp.
546
553
.
23.
Hernandez
,
C. J.
, and
Keaveny
,
T. M.
, 2006, “
A Biomechanical Perspective on Bone Quality
,”
Bone
,
39
(
6
), pp.
1173
1181
. 8756-3282
24.
Keaveny
,
T. M.
,
Morgan
,
E. F.
,
Niebur
,
G. L.
, 2001, “
Biomechanics of Trabecular Bone
,”
Annu. Rev. Biomed. Eng.
1523-9829,
3
, pp.
307
333
.
25.
Yerby
,
S. A.
,
Bay
,
B. K.
, and
Toh
,
E.
, 1998, “
The Effect of Boundary Conditions on Experimentally Measured Trabecular Strain in the Thoracic Spine
,”
J. Biomech.
0021-9290,
31
(
10
), pp.
891
897
.
26.
McKinley
,
T. O.
, and
Bay
,
B. K.
, 2001, “
Trabecular Bone Strain Changes Associated With Cartilage Defects in the Proximal and Distal Tibia
,”
J. Orthop. Res.
0736-0266,
19
(
5
), pp.
906
913
.
27.
Norrdin
,
R. W.
,
Bay
,
B. K.
, and
Drews
,
M. J.
, 2001, “
Overload Arthrosis: Strain Patterns in the Equine Metacarpal Condyle
,”
Journal of Musculoskeletal & Neuronal Interactions
,
1
(
4
), pp.
357
362
. 1108-7161
28.
Toh
,
E.
,
Yerby
,
S. A.
, and
Bay
,
B. K.
, 2001, “
The Effect of Anterior Osteophytes and Flexural Position on Thoracic Trabecular Strain
,”
Spine
0362-2436,
26
(
1
), pp.
22
26
.
29.
Bey
,
M. J.
,
Song
,
H. K.
, and
Wehrli
,
F. W.
, 2002, “
A Noncontact, Nondestructive Method for Quantifying Intratissue Deformations and Strains
,”
ASME J. Biomech. Eng.
0148-0731,
124
(
2
), pp.
253
258
.
30.
McKinley
,
T. O.
, and
Bay
,
B. K.
, 2003, “
Trabecular Bone Strain Changes Associated With Subchondral Stiffening of the Proximal Tibia
,”
J. Biomech.
0021-9290,
36
(
2
), pp.
155
163
.
31.
Toh
,
E.
,
Yerby
,
S. A.
, and
Bay
,
B. K.
, 2005, “
The Behavior of Thoracic Trabecular Bone During Flexion
,”
Tokai J. Exp. Clin. Med.
0385-0005,
30
(
3
), pp.
163
170
.
32.
Toh
,
E.
,
Yerby
,
S. A.
, and
Bay
,
B. K.
, 2006, “
The Influence of Pedicle Screw Placement on Thoracic Trabecular Strain
,”
Spinal Cord
1362-4393,
44
(
4
), pp.
249
253
.
You do not currently have access to this content.