Contact forces and moments act on orthopaedic implants such as joint replacements. The three forces and three moment components can be measured by six internal strain gauges and wireless telemetric data transmission. The accuracy of instrumented implants is restricted by their small size, varying modes of load transfer, and the accuracy of calibration. Aims of this study were to test with finite element studies design features to improve the accuracy, to develop simple but accurate calibration arrangements, and to select the best mathematical method for calculating the calibration constants. Several instrumented implants, and commercial and test transducers were calibrated using different loading setups and mathematical methods. It was found that the arrangement of flexible elements such as bellows or notches between the areas of load transfer and the central sensor locations is most effective to improve the accuracy. Increasing the rigidity of the implant areas, which are fixed in bones or articulate against joint surfaces, is less effective. Simple but accurate calibration of the six force and moment components can be achieved by applying eccentric forces instead of central forces and pure moments. Three different methods for calculating the measuring constants proved to be equally well suited. Employing these improvements makes it possible to keep the average measuring errors of many instrumented implants below 1–2% of the calibration ranges, including cross talk. Additional errors caused by noise of the transmitted signals can be reduced by filtering if this is permitted by the sampling rate and the required frequency content of the loads.

1.
Rydell
,
N. W.
, 1966, “
Forces Acting in the Femoral Head-Prosthesis
,”
Acta Orthop. Scand. Suppl.
0300-8827,
37
(
88
), pp.
1
132
.
2.
Davy
,
D. T.
,
Kotzar
,
G. M.
,
Brown
,
R. H.
,
Heiple
,
K. G.
,
Goldberg
,
V. M.
,
Heiple
,
K. G.
, Jr.
,
Berilla
,
J.
, and
Burstein
,
A. H.
, 1988, “
Telemetric Force Measurements Across the Hip After Total Arthroplasty
,”
J. Bone Jt. Surg., Am. Vol.
0021-9355,
70-A
, pp.
45
50
.
3.
Kotzar
,
G. M.
,
Davy
,
D. T.
,
Goldberg
,
V. M.
,
Heiple
,
K. G.
,
Berilla
,
J.
,
Heiple
, Jr.
K. G.
,
Brown
,
R. H.
, and
Burstein
,
A. H.
, 1991, “
Telemeterized In Vivo Hip Joint Force Data: A Report on Two Patients After Total Hip Surgery
,”
J. Orthop. Res.
0736-0266,
9
, pp.
621
633
.
4.
Kotzar
,
G. M.
,
Davy
,
D. T.
,
Berilla
,
J.
, and
Goldberg
,
V. M.
, 1995, “
Torsional Loads in the Early Postoperative Period Following Total Hip Replacement
,”
J. Orthop. Res.
0736-0266,
13
, pp.
945
555
.
5.
Carlson
,
K. L.
, 1993, “
Human Hip Joint Mechanics—An Investigation Into the Effects of Femoral Head Endoprosthetic Replacement Using In Vitro and In Vivo Pressure Data
,” Ph.D. thesis, Department of Mechanical Engineering, M.I.T., Boston, MA.
6.
Taylor
,
S. J. G.
,
Perry
,
J. S.
,
Adler
,
J. R.
, and
Walker
,
P. S.
, 1994, “
The Telemetry of Forces In Vivo in Massive Orthopaedic Implants in Relation to Loosening
,”
Trans. Annu. Meet. - Orthop. Res. Soc.
0149-6433,
19
, p.
809
.
7.
Taylor
,
S. J. G.
,
Perry
,
J. S.
,
Meswania
,
J. M.
,
Donaldson
,
N.
,
Cannon
,
S. R.
, and
Walker
,
P. S.
, 1997, “
Telemetry of Forces From Proximal Femoral Replacements and Relevance to Fixation
,”
J. Biomech.
0021-9290,
30
, pp.
225
234
.
8.
Taylor
,
S. J.
,
Walker
,
P. S.
,
Perry
,
J. S.
,
Cannon
,
S. R.
, and
Woledge
,
R.
, 1998, “
The Forces in the Distal Femur and the Knee During Walking and Other Activities Measured by Telemetry
,”
J. Arthroplasty
0883-5403,
13
, pp.
428
437
.
9.
Taylor
,
S. J.
, and
Walker
,
P. S.
, 2001, “
Forces and Moments Telemetered from Two Distal Femoral Replacements During Various Activities
,”
J. Biomech.
0021-9290,
34
, pp.
839
848
.
10.
Taylor
,
S. J. G.
,
Gorjon
,
J.
, and
Gorjon
,
A.
, 2000, “
Development of an Instrumented Tibial Tray for Knee Force Measurement In Vivo
,”
Proceedings of the 12th Conference of the European Society on Biomechanics
, Dublin, Ireland, p.
110
.
11.
Taylor
,
S. J. G.
,
Meswania
,
J. M.
,
Rodríguez-Arias
,
J.
,
Calle
,
R.
,
Bayley
,
I. L.
, and
Blunn
,
G. W.
, 2004, “
An Instrumented Implant and Calibration Technique for Measurement of Glenohumeral Joint Forces In Vivo
,”
Proceedings of the 14th Conference of the European Society on Biomechanics
, S-Hertogenbosch, The Netherlands.
12.
Morris
,
B. A.
,
D’Lima
,
D. D.
,
Slamin
,
J.
,
Kovacevic
,
N.
,
Arms
,
S. W.
,
Townsend
,
C. P.
, and
Colwell
, Jr.
C. W.
, 2001, “
E-Knee: Evolution of the Electronic Knee Prosthesis. Telemetry Technology Development
,”
J. Bone Jt. Surg., Am. Vol.
0021-9355,
83-A
(
2
), pp.
62
66
.
13.
D’Lima
,
D. D.
,
Slamin
,
J.
,
Townsend
,
C.
,
Arms
,
S.
,
Kovacevic
,
N.
,
Morris
,
B.
, and
Colwell
,
C.
, 2002, “
Measurement of Tibiofemoral Forces In Vivo
,”
Trans. Annu. Meet. - Orthop. Res. Soc.
0149-6433,
27
.
14.
D’Lima
,
D. D.
,
Patil
,
S.
,
Steklov
,
N.
, and
Colwell
, Jr.
C. W.
, 2004, “
In Vitro and In Vivo Measurement of Dynamic Soft-Tissue Balancing During Total Knee Arthroplasty With an Instrumented Tibial Prosthesis
,”
Trans. Annu. Meet. - Orthop. Res. Soc.
0149-6433,
29
.
15.
D’Lima
,
D. D.
,
Townsend
,
C. P.
,
Arms
,
S. W.
,
Morris
,
B. A.
, and
Colwell
,
C. W.
, 2005, “
An Implantable Telemetry Device to Measure Intra-Articular Tibial Forces
,”
J. Biomech.
0021-9290,
38
, pp.
299
304
.
16.
Bergmann
,
G.
,
Siraky
,
J.
,
Rohlmann
,
A.
, and
Kölbel
,
R.
, 1985, “
A Comparison of Hip Joint Force in Sheep, Dog and Man
,”
J. Biomech.
0021-9290,
17
, pp.
907
921
.
17.
Bergmann
,
G.
,
Graichen
,
F.
, and
Rohlmann
,
A.
, 1999, “
Hip Joint Forces in Sheep
,”
J. Biomech.
0021-9290,
32
, pp.
769
777
.
18.
Bergmann
,
G.
,
Graichen
,
F.
, and
Rohlmann
,
A.
, 1993, “
Hip Joint Forces During Walking and Running, Measured in Two Patients
,”
J. Biomech.
0021-9290,
26
, pp.
969
990
.
19.
Bergmann
,
G.
,
Graichen
,
F.
, and
Rohlmann
,
A.
, 1995, “
Is Staircase Walking a Risk for the Fixation of Hip Implants?
,”
J. Biomech.
0021-9290,
28
, pp.
535
553
.
20.
Bergmann
,
G.
,
Kniggendorf
,
H.
,
Graichen
,
F.
, and
Rohlmann
,
A.
, 1995, “
Influence of Shoes and Heel Strike on the Loading of Hip Implants
,”
J. Biomech.
0021-9290,
28
, pp.
817
827
.
21.
Bergmann
,
G.
,
Graichen
,
F.
, and
Rohlmann
,
A.
, 1997, “
Hip Joint Forces During Load Carrying
,”
Clin. Orthop. Relat. Res.
0009-921X,
335
, pp.
190
201
.
22.
Bergmann
,
G.
,
Graichen
,
F.
,
Rohlmann
,
A.
,
Verdonschot
,
N.
, and
Van Lenthe
,
G. H.
, 2001, “
Frictional Heating in and Around Hip Implants, Part 1: Measurements in Patients
,”
J. Biomech.
0021-9290,
34
, pp.
421
428
.
23.
Bergmann
,
G.
,
Graichen
,
F.
,
Rohlmann
,
A.
,
Verdonschot
,
N.
, and
Van Lenthe
,
G. H.
, 2001, “
Frictional Heating in and Around Hip Implants, Part 2: Finite Element Study
,”
J. Biomech.
0021-9290,
34
, pp.
429
435
.
24.
Bergmann
,
G.
,
Graichen
,
F.
, and
Rohlmann
,
A.
, 2001, “
Hip Contact Forces and Gait Patterns From Routine Activities
,”
J. Biomech.
0021-9290,
34
, pp.
859
871
.
25.
Bergmann
,
G.
, 2001, “
HIP98—Loading of the Hip Joint
,”
Free University of Berlin
, Germany, CompactDdisc, ISBN 3980784800.
26.
Bergmann
,
G.
,
Graichen
,
F.
, and
Rohlmann
,
A.
, 2004, “
Hip Joint Contact Forces During Stumbling
,”
Langenbecks Arch. Surg.
1435-2443,
389
, pp.
53
59
.
27.
Rohlmann
,
A.
,
Bergmann
,
G.
, and
Graichen
,
F.
, 1994, “
A Spinal Fixation Device for In Vivo Load Measurement
,”
J. Biomech.
0021-9290,
27
, pp.
961
967
.
28.
Rohlmann
,
A.
,
Bergmann
,
G.
, and
Graichen
,
F.
, 1999, “
Loads on Internal Spinal Fixators Measured in Different Body Positions
,”
Eur. Spine J.
0940-6719,
8
, pp.
354
359
.
29.
Rohlmann
,
A.
,
Graichen
,
F.
,
Weber
,
U.
, and
Bergmann
,
G.
, 2000, “
Monitoring In Vivo Implant Loads With a Telemeterized Internal Spinal Fixation Device
,”
Spine
0362-2436,
25
, pp.
2981
2986
.
30.
Bergmann
,
G.
,
Graichen
,
F.
,
Bender
,
A.
,
Kääb
,
M.
,
Rohlmann
,
A.
, and
Westerhoff
,
P.
, “
In-Vivo Glenohumeral Contact Forces—Measurements in the First Patient Seven Months Postoperatively
,”
J. Biomech.
0021-9290, in press.
31.
Rohlmann
,
A.
,
Gabel
,
U.
,
Graichen
,
F.
,
Bender
,
A.
, and
Bergmann
,
G.
, 2007, “
An Instrumented Implant for Vertebral Body Replacement that Measures Loads in the Anterior Spinal Column
,”
Med. Eng. Phys.
1350-4533,
29
, pp.
580
585
.
32.
Heinlein
,
B.
,
Rohlmann
,
A.
,
Graichen
,
F.
, and
Bergmann
,
G.
, 2005, “
An Instrumented Knee Endoprosthesis for Measuring Loads In Vivo
,”
Transactions of the 51st Annual Meeting of Orthopaedic Research Society
, Washington, DC, Poster No. 1217.
33.
Heinlein
,
B.
,
Rohlmann
,
A.
,
Graichen
,
F.
, and
Bergmann
,
G.
, 2006, “
Accuracy Analysis of an Instrumented Total Knee Arthroplasty for Multi-Component Measurements of In Vivo Forces
,”
Transactions of the 52nd Annual Meeting of the Orthopaedic Research Society
, Chicago, IL, Paper No. 0625.
34.
Singerman
,
R.
,
Berilla
,
J.
,
Kotzar
,
G.
,
Daly
,
J.
, and
Davy
,
D. T.
, 1994, “
A Six-Degree-of-Freedom Transducer for In Vitro Measurement of Patellofemoral Contact Forces
,”
J. Biomech.
0021-9290,
27
, pp.
233
238
.
35.
Bergmann
,
G.
, 1981, “
Ein Dreikomponenten-Kraftaufnehmer und Seine Anwendung für die Messung von Gelenkkräften am Tier
,” Ph.D. thesis, Technische Universität Berlin, Germany.
36.
Bergmann
,
G.
,
Siraky
,
J.
,
Rohlmann
,
A.
, and
Kölbel
,
R.
, 1982, “
Measurement of Spatial Forces by the ‘Matrix’-Method
,”
Proceedings of the Ninth World Congress IMEKO
, Berlin, Germany, pp.
395
404
.
37.
Graichen
,
F.
,
Bergmann
,
G.
, and
Rohlmann
,
A.
, 1996, “
Patient Monitoring System for Load Measurement With Spinal Fixation Devices
,”
Med. Eng. Phys.
1350-4533,
18
, pp.
167
174
.
38.
Graichen
,
F.
,
Bergmann
,
G.
, and
Rohlmann
,
A.
, 1999, “
Hip Endoprosthesis for In Vivo Measurement of Joint Force and Temperature
,”
J. Biomech.
0021-9290,
32
, pp.
1113
1117
.
39.
Graichen
,
F.
,
Rohlmann
,
A.
,
Arnold
,
R.
, and
Bergmann
,
G.
, 2007, “
Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants
,”
IEEE Trans. Biomed. Eng.
0018-9294,
54
, pp.
253
261
.
40.
Björk
,
A.
, 1996,
Numerical Methods for Least Squares Problems
,
Linköping University
,
Sweden
.
41.
Van Huffel
,
S.
, and
Lemmerling
,
P.
, 2002,
Total Least Squares and Errors-in-Variable Modelling, Analysis, Algorithms and Applications
,
Kluwer
,
Dordrecht
.
42.
Heinlein
,
B.
,
Rohlmann
,
A.
,
Graichen
, and
F.
,
Bergmann
,
G.
, 2006, “
Accuracy of an Instrumented Total Knee Arthroplasty for Six-Component In Vivo Load Measurements
,”
52nd Annual Meeting of the Orthopaedic Research Society
, Chicago, IL, Paper No. 0605.
You do not currently have access to this content.