Abstract

Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4to7mmHg, respectively, at 5lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1to4.5mmHglpm at 5lpm and with concomitant increases in gradient up to 17mmHg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18mmHg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device.

1.
Bonow
,
R. O.
,
Carabello
,
B.
,
de Leon
,
A. C.
,
Edmunds
,
L. H.
,
Fedderly
,
B. J.
,
Freed
,
M. D.
,
Gaasch
,
W. H.
,
McKay
,
C. R.
,
Nishimura
,
R. A.
,
O’Gara
,
P. T.
,
O’Rourke
,
R. A.
, and
Rahimtoola
,
S. H.
, 1998, “
ACC∕AHA Guidelines on the Management of Patients With Valvular Heart Disease: Executive Summary
,”
Circulation
0009-7322,
98
, pp.
1949
1984
.
2.
Hillman
,
N. D.
,
Mavroudis
,
C.
, and
Backer
,
C. L.
,
2003
,
Adult Congenital Heart Disease
, in Pediatric Cardiac Surgery, 3rd ed,
C.
Mavroudis
and
C. L.
Backer
, eds.,
Mosby
,
Philadelphia
, chap. 48.
3.
de Ruijter
,
F. T. H.
,
Weenink
,
I.
,
Hitchcock
,
F. J.
,
Meijboom
,
E. J.
, and
Benninck
,
G. B. W. E.
, 2000, “
Right Ventricular Dysfunction and Pulmonary Valve Replacement After Correction of Tetralogy of Fallot
,”
Ann. Thorac. Surg.
0003-4975,
73
, pp.
1794
1800
.
4.
Ilbawi
,
M. N.
,
Lockhart
,
C. G.
,
Idriss
,
F. S.
,
DeLeon
,
S. Y.
,
Muster
,
A. J.
,
Duffy
,
C. E.
, and
Paul
,
M. H.
, 1987, “
Experience With St. Jude Medical Valve Prosthesis in Children: A Word of Caution Regarding Right-Sided Placement
,”
J. Thorac. Cardiovasc. Surg.
0022-5223,
93
(
1
), pp.
73
79
.
5.
Ilbawi
,
M. N.
,
Idriss
,
F. S.
,
DeLeon
,
S. Y.
,
Muster
,
A. J.
,
Duffy
,
C. E.
,
Gidding
,
S. S.
, and
Paul
,
M. H.
, 1987, “
Valve Replacement in Children: Guidelines for Selection of Prosthesis and Timing Surgical Intervention
,”
Ann. Thorac. Surg.
0003-4975,
44
(
4
), pp.
398
403
.
6.
Kawachi
,
Y.
,
Masuda
,
M.
,
Tominaga
,
R.
, and
Tokunaga
,
K.
, 1991, “
Comparative Study Between St. Jude Medical and Bioprosthetic Valves in the Right Side of the Heart
,”
Jpn. Circ. J.
0047-1828,
55
(
6
), pp.
553
362
.
7.
Rosti
,
L.
,
Murzi
,
B.
,
Colli
,
A. M.
,
Festa
,
P.
,
Redaelli
,
S.
,
Havelova
,
L.
,
Menicanti
,
L.
, and
Frigiola
,
A.
, 1998, “
Mechanical Valves in the Pulmonary Position: A. Reappraisal
,”
J. Thorac. Cardiovasc. Surg.
0022-5223,
115
(
5
), pp.
1074
1079
.
8.
Meuris
,
B.
,
Verbeken
,
E.
, and
Fameng
,
W.
, 2005, “
Mechanical Valve Thrombosis in a Chronic Animal Model: Differences Between Monoleaflet and Bileaflet Valves
,”
J. Heart Valve Dis.
0966-8519,
14
(
1
), pp.
96
104
.
9.
Gohean
,
J.
,
Figliola
,
R.
,
Camp
,
T.
, and
McQuinn
,
T.
, 2006, “
Comparative in vitro Study of Bileaflet and Tilting Disk Valve Behavior in the Pulmonary Position
,”
ASME J. Biomech. Eng.
0148-0731,
128
, pp.
631
635
.
10.
Kiyota
,
Y.
,
Shiroyama
,
T.
,
Akamatsu
,
T.
,
Yokota
,
Y.
, and
Ban
,
T.
, 1992, “
In Vitro Closing Behavior of the St. Jude Medical Heart Valve in the Pulmonary Position
,”
J. Thorac. Cardiovasc. Surg.
0022-5223,
104
(
3
), pp.
779
85
.
11.
Philpot
,
E.
,
Yoganathan
,
A. P.
,
Woo
,
Y.
,
Sung
,
H.
,
Franch
,
R.
,
Sahn
,
D.
, and
Valdes-Cruz
,
L.
, 1985, “
In vitro Pulsatile Flow Visualization Studies in a Pulmonary Artery Model
,”
ASME J. Biomech. Eng.
0148-0731,
107
, pp.
368
375
.
12.
Sung
,
H.
,
Philpot
,
E.
,
Nanda
,
N.
, and
Yoganathan
,
A.
, 1993, “
Axial Flow Patterns in a Pulmonary Artery Model With Varying Degrees of Pulmonic Stenosis—Pulsatile in vitro Studies
,”
J. Biomech.
0021-9290,
23
, pp.
563
578
.
13.
Sung
,
H.
,
Hsu
,
T.
,
Hsu
,
C.
, and
Hsu
,
J.
, 1998, “
Pulmonary Artery Hemodynamics With Varying Degrees of Valvular Stenosis: In vitro Study
,”
J. Biomech.
0021-9290,
31
, pp.
1153
1161
.
14.
Geva
,
T.
,
Sandweiss
,
B. M.
,
Gauvreau
,
K.
,
Lock
,
J. E.
, and
Powell
,
A. J.
, 2004, “
Factors Associated With Impaired Clinical Status in Long-Term Survivors of Tetralogy of Fallot Repair Evaluated by Magnetic Resonance Imaging
,”
J. Am. Coll. Cardiol.
0735-1097,
43
, pp.
1068
1074
.
15.
Essential Cardiology: Principles and Practice
, 2001,
C.
Rosendorff
, ed.,
W.B. Saunders
,
New York
.
16.
Backer
,
C. L.
, and
Mavroudis
,
C.
, 2003, “
Atrial Septal Defect, Partial Anomalous Pulmonary Venous Connection, and Scimitar Syndrome
,” in
Pediatric Cardiac Surgery
,
Mosby
,
Philadelphia
,
C.
Mavroudis
and
C. L.
Backer
, eds., chap. 16, pp.
283
297
.
17.
Paul
,
F. W.
, 1969, “
Fluid Mechanics of the Momentum Flueric Diode
,”
Proceedings IFAC Symposium on Fluidics
,
Peter Peregrinus Ltd.
,
London
, Paper A1, pp.
1
15
.
18.
Baker
,
P. J.
, 1967, “
Comparison of Fluid Diodes
,”
Brit Hydromech Res
,
D6
, pp.
88
115
.
19.
Linderoth
,
E. T.
, 1955, “
Aerodynamic Check Valve
,” US Patent No. 2,727,535.
20.
Conway
,
A.
, 1971,
Guide to Fluidics
,
Macdonald
,
London
.
21.
Tesla
,
N.
, 1920, “
Valvular Conduit
,” US Patent No. 13,295,59.
22.
ANSI∕AAMI∕ISO 5840, 2005, “
Cardiovascular Implants: Cardiac Valve Prostheses
,” AAMI, Arlington, VA.
23.
Figliola
,
R. S.
, and
Beasley
,
D. E.
, 2005,
Theory and Design for Mechanical Measurements
, 4th ed.,
Wiley
,
New York
, chaps. 4 and 5.
24.
Fluid meters: Their Theory and Application
, 6th ed., 1971,
H. S.
Bean
, ed.,
American Society of Mechanical Engineers
,
New York
.
25.
Yoganathan
,
A.
, and
Travis
,
B.
, 2000, “
Fluid Dynamics of Prosthetic Valves
,” in
Practice of Clinical Endocardiograhpy
,
C. M.
Otto
, ed.,
W.B. Saunders
,
Philadelphia
.
26.
Chandran
,
K.
, 1985, “
Pulsatile Flow Past SJMBV: In vitro Study
,”
J. Thorac. Cardiovasc. Surg.
0022-5223,
89
, pp.
743
749
.
You do not currently have access to this content.