The mechanical properties of cancellous bone and the biological response of the tissue to mechanical loading are related to deformation and strain in the trabeculae during function. Due to the small size of trabeculae, their motion is difficult to measure. To avoid the need to measure trabecular motions during loading the finite element method has been used to estimate trabecular level mechanical deformation. This analytical approach has been empirically successful in that the analytical models are solvable and their results correlate with the macroscopically measured stiffness and strength of bones. The present work is a direct comparison of finite element predictions to measurements of the deformation and strain at near trabecular level. Using the method of digital volume correlation, we measured the deformation and calculated the strain at a resolution approaching the trabecular level for cancellous bone specimens loaded in uniaxial compression. Smoothed results from linearly elastic finite element models of the same mechanical tests were correlated to the empirical three-dimensional (3D) deformation in the direction of loading with a coefficient of determination as high as 97% and a slope of the prediction near one. However, real deformations in the directions perpendicular to the loading direction were not as well predicted by the analytical models. Our results show, that the finite element modeling of the internal deformation and strain in cancellous bone can be accurate in one direction but that this does not ensure accuracy for all deformations and strains.
Skip Nav Destination
Article navigation
February 2006
Technical Papers
Comparison of the Linear Finite Element Prediction of Deformation and Strain of Human Cancellous Bone to 3D Digital Volume Correlation Measurements
R. Zauel,
R. Zauel
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202
Search for other works by this author on:
Y. N. Yeni,
Y. N. Yeni
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202
Search for other works by this author on:
B. K. Bay,
B. K. Bay
Oregon State University
, Corvallis, OR 97331
Search for other works by this author on:
X. N. Dong,
X. N. Dong
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202
Search for other works by this author on:
D. P. Fyhrie
D. P. Fyhrie
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202
Search for other works by this author on:
R. Zauel
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202
Y. N. Yeni
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202
B. K. Bay
Oregon State University
, Corvallis, OR 97331
X. N. Dong
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202
D. P. Fyhrie
Bone and Joint Center,
Department of Orthopaedic Surgery
, Henry Ford Health System, Detroit, MI 48202J Biomech Eng. Feb 2006, 128(1): 1-6 (6 pages)
Published Online: July 21, 2005
Article history
Received:
November 3, 2003
Revised:
July 21, 2005
Citation
Zauel, R., Yeni, Y. N., Bay, B. K., Dong, X. N., and Fyhrie, D. P. (July 21, 2005). "Comparison of the Linear Finite Element Prediction of Deformation and Strain of Human Cancellous Bone to 3D Digital Volume Correlation Measurements." ASME. J Biomech Eng. February 2006; 128(1): 1–6. https://doi.org/10.1115/1.2146001
Download citation file:
Get Email Alerts
Related Articles
In Vivo Model for Evaluating the Effects of Mechanical Stimulation on Tissue-Engineered Bone Repair
J Biomech Eng (August,2009)
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Biomechanical Validation of Finite Element Models for Two Silicone Metacarpophalangeal Joint Implants
J Biomech Eng (February,2011)
Related Proceedings Papers
Related Chapters
Data Tabulations
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Conclusion
Ultrasonic Methods for Measurement of Small Motion and Deformation of Biological Tissues for Assessment of Viscoelasticity
Numerical Simulation of Spatial Synergic Interaction in the Double-Row Anti-Sliding Piles
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)