The mechanical properties of cancellous bone and the biological response of the tissue to mechanical loading are related to deformation and strain in the trabeculae during function. Due to the small size of trabeculae, their motion is difficult to measure. To avoid the need to measure trabecular motions during loading the finite element method has been used to estimate trabecular level mechanical deformation. This analytical approach has been empirically successful in that the analytical models are solvable and their results correlate with the macroscopically measured stiffness and strength of bones. The present work is a direct comparison of finite element predictions to measurements of the deformation and strain at near trabecular level. Using the method of digital volume correlation, we measured the deformation and calculated the strain at a resolution approaching the trabecular level for cancellous bone specimens loaded in uniaxial compression. Smoothed results from linearly elastic finite element models of the same mechanical tests were correlated to the empirical three-dimensional (3D) deformation in the direction of loading with a coefficient of determination as high as 97% and a slope of the prediction near one. However, real deformations in the directions perpendicular to the loading direction were not as well predicted by the analytical models. Our results show, that the finite element modeling of the internal deformation and strain in cancellous bone can be accurate in one direction but that this does not ensure accuracy for all deformations and strains.

1.
Silva
,
M. J.
,
Keaveny
,
T. M.
, and
Hayes
,
W. C.
1997, “
Load Sharing Between The Shell And Centrum In The Lumbar Vertebral Body
,”
Spine
0362-2436,
22
(
2
): pp.
140
150
.
2.
Silva
,
M. J.
,
Keaveny
,
T. M.
, and
Hayes
,
W. C.
, 1998, “
Computed Tomography-Based Finite Element Analysis Predicts Failure Loads and Fracture Patterns for Vertebral Sections
,”
J. Orthop. Res.
0736-0266,
16
(
3
), pp.
300
308
.
3.
Mizrahi
,
J.
, et al.
, 1993, “
Finite-Element Stress Analysis of the Normal and Osteoporotic Lumbar Vertebral Body
,”
Spine
0362-2436,
18
(
14
), pp.
2088
2096
.
4.
Niebur
,
G. L.
, et al.
, 2000, “
High-Resolution Finite Element Models With Tissue Strength Asymmetry Accurately Predict Failure of Trabecular Bone
,”
J. Biomech.
0021-9290,
33
(
12
), pp.
1575
1583
.
5.
Liebschner
,
M. A.
, et al.
, 2003, “
Finite Element Modeling of the Human Thoracolumbar Spine
,”
Spine
0362-2436,
28
(
6
), pp.
559
565
.
6.
Cody
,
D. D.
, et al.
, 1999, “
Femoral Strength is Better Predicted by Finite Element Models Than QCT and DXA
,”
J. Biomech.
0021-9290,
32
(
10
), pp.
1013
1020
.
7.
Cody
,
D. D.
, et al.
, 2000, “
Femoral Structure and Stiffness in Patients With Femoral Neck Fracture
,”
J. Orthop. Res.
0736-0266,
18
(
3
), pp.
443
448
.
8.
Cody
,
D. D.
, et al.
, 2000, “
Short Term in Vivo Precision of Proximal Femoral Finite Element Modeling
,”
Ann. Biomed. Eng.
0090-6964,
28
(
4
), pp.
408
414
.
9.
Crawford
,
R. P.
,
Cann
,
C. E.
, and
Keaveny
,
T. M.
, 2003, “
Finite Element Models Predict in Vitro Vertebral Body Compressive Strength Better Than Quantitative Computed Tomography
,”
Bone (N.Y.)
8756-3282,
33
(
4
), pp.
744
750
.
10.
Crawford
,
R. P.
,
Rosenberg
,
W. S.
, and
Keaveny
,
T. M.
, 2003, “
Quantitative Computed Tomography-Based Finite Element Models of the Human Lumbar Vertebral Body: Effect of Element Size on Stiffness, Damage, and Fracture Strength Predictions
,”
J. Biomech. Eng.
0148-0731,
125
(
4
), pp.
434
438
.
11.
Fyhrie
,
D. P.
, et al.
, 2000, “
Shear Stress Distribution in the Trabeculae of Human Vertebral Bone
,”
Ann. Biomed. Eng.
0090-6964,
28
(
10
), pp.
1194
1199
.
12.
Hou
,
F. J.
, et al.
, 1998, “
Human Vertebral Body Apparent and Hard Tissue Stiffness
,”
J. Biomech.
0021-9290,
31
(
11
), p.
1009
1015
.
13.
Jaasma
,
M. J.
, et al.
, 2002, “
Biomechanical Effects of Intraspecimen Variations in Tissue Modulus for Trabecular Bone
,”
J. Biomech.
0021-9290,
35
(
2
), pp.
237
246
.
14.
Van Rietbergen
,
B.
, et al.
, 1999, “
Tissue Stresses and Strain in Trabeculae of a Canine Proximal Femur can be Quantified From Computer Reconstructions
,”
J. Biomech.
0021-9290,
32
(
4
), pp.
443
451
.
15.
van Rietbergen
,
B.
, 2001, “
Micro-FE Analyses of Bone: State of the art
,”
Adv. Exp. Med. Biol.
0065-2598,
496
, pp.
21
30
.
16.
van Rietbergen
,
B.
, et al.
, 2002, “
High-Resolution MRI and Micro-FE for the Evaluation of Changes in Bone Mechanical Properties During Longitudinal Clinical Trials: Application to Calcaneal Bone in Postmenopausal Women After one Year of Idoxifene Treatment
,”
Clin. Biomech. (Bristol, Avon)
0268-0033,
17
(
2
), pp.
81
88
.
17.
Yeni
,
Y. N.
and
Fyhrie
,
D. P.
, 2001, “
Finite Element Calculated Uniaxial Apparent Stiffness is a Consistent Predictor of Uniaxial Apparent Strength in Human Vertebral Cancellous Bone Tested With Different Boundary Conditions
,”
J. Biomech.
0021-9290,
34
(
12
), pp.
1649
1654
.
18.
Yeni
,
Y. N.
, et al.
, 2003, “
Trabecular Shear Stresses Predict in Vivo Linear Microcrack Density but not Diffuse Damage in Human Vertebral Cancellous Bone
,”
Ann. Biomed. Eng.
0090-6964,
31
(
7
), pp.
726
732
.
19.
Ulrich
,
D.
, et al.
, 1999, “
Load Transfer Analysis of the Distal Radius From in-Vivo High-Resolution CT-Imaging
,”
J. Biomech.
0021-9290,
32
(
8
), pp.
821
828
.
20.
Huiskes
,
R.
, 1982, “
On the Modelling of Long Bones in Structural Analyses
,”
J. Biomech.
0021-9290,
15
(
1
), pp.
65
69
.
21.
Guo
,
X. E.
, et al.
, 2002, “
Quantification of a rat Tail Vertebra Model for Trabecular Bone Adaptation Studies
,”
J. Biomech.
0021-9290,
35
(
3
), pp.
363
368
.
22.
Akhter
,
M. P.
, et al.
, 1992, “
Characterization of in Vivo Strain in the rat Tibia During External Application of a Four-Point Bending Load
,”
J. Biomech.
0021-9290,
25
(
10
), pp.
1241
1246
.
23.
Bay
,
B. K.
, 1995, “
Texture Correlation: A Method for the Measurement of Detailed Strain Distributions Within Trabecular Bone
,”
J. Orthop. Res.
0736-0266,
13
, pp.
258
267
.
24.
Bay
,
B. K.
, et al.
, 1999, “
Digital Volume Correlation: Three-Dimensional Strain Mapping Using X-Ray Tomography
,”
Exp. Mech.
0014-4851,”
39
(
3
), pp.
217
226
.
25.
Smith
,
T.
,
Bay
,
B.
, and
Rashid
,
M.
, 2002, “
Digital Volume Correlation Including Rotational Degrees of Freedom During Minimization
,”
Exp. Mech.
0014-4851,
42
(
3
), pp.
272
278
.
26.
Odgaard
,
A.
,
Hvid
,
I.
, and
Linde
,
F.
, 1989, “
Compressive Axial Strain Distributions in Cancellous Bone Specimens
,”
J. Biomech.
0021-9290,
22
(
8-9
), pp.
829
835
.
27.
Nicolella
,
D. P.
, et al.
, 2001, “
Machine Vision Photogrammetry: a Technique for Measurement of Microstructural Strain in Cortical Bone
,”
J. Biomech.
0021-9290,
34
(
1
), pp.
135
139
.
28.
Reimann
,
D. A.
, et al.
, 1997, “
A Cone Beam Computed Tomography System for True 3D Imaging of Specimens
,”
Appl. Radiat. Isot.
0969-8043,
48
(
10-12
), pp.
1433
1436
.
29.
Luenberger
,
D. G.
, 1973,
Introduction to Linear and Nonlinear Programming
,
Addison-Wesley
, Reading.
30.
Malvern
,
L. E.
, 1969,
Introduction to the Mechanics of a Continuous Medium
,
Prentice-Hall, Inc.
, Englewood Cliffs.
31.
Niebur
.
G. L.
, et al.
, 1999, “
Convergence Behavior of High-Resolution Finite Element Models of Trabecular Bone
,”
J. Biomech. Eng.
0148-0731,
121
(
6
), pp.
629
635
.
32.
Charras
,
G. T.
and
Guldberg
,
R. E.
, 2000, “
Improving the Local Solution Accuracy of Large-Scale Digital Image-Based Finite Element Analyses
,”
J. Biomech.
0021-9290,
33
(
2
), pp.
255
259
.
33.
Guldberg
,
R. E.
,
Hollister
,
S. J.
, and
Charras
,
G. T.
, 1998, “
The Accuracy of Digital Image-Based Finite Element Models
,”
J. Biomech. Eng.
0148-0731,
120
(
2
), pp.
289
295
.
34.
Rho
,
J. Y.
, et al.
, 2002, “
Microstructural Elasticity and Regional Heterogeneity in Human Femoral Bone of Various Ages Examined by Nano-Indentation
,”
J. Biomech.
0021-9290,
35
(
2
), pp.
189
198
.
35.
Rho
,
J. Y.
,
Kuhn-Spearing
,
L.
, and
Zioupos
,
P.
, 1998, “
Mechanical Properties and the Hierarchical Structure of Bone
,”
Med. Eng. Phys.
1350-4533,
20
(
2
), pp.
92
102
.
You do not currently have access to this content.