Diagnostic and rehabilitative assessments of hand function commonly omit measurement of twisting strength even though many activities of daily living require turning handles, lids, and objects of many sizes. A simple device to quantify twisting strength was designed and constructed to establish normative data and test hypotheses about hand function. The instrument is easy to use and includes an electronic torsional load cell and disks of several sizes. Tests were conducted on the dominant and nondominant hands of 64 normal subjects and 13 arthritic patients with arthritis of the thumb carpometacarpal joint. Hands were tested with disks ranging in diameter from 2.5to12.5cm. A three-way repeated measures analysis showed that gender (p<0.001), handedness (p<0.001), and disk size (p<0.001) had significant effects. There was no difference between radial and ulnar deviation strengths (p=0.365). The arthritic group had significantly reduced strength (p<0.02). Nine subjects were tested twice, with 1day between tests: no differences occurred between the first and second testing (p=0.930). The ability to distinguish the test groups with reproducible results proves that the device fulfills all basic requirements; continued testing and development are warranted.

1.
Mathiowetz
,
V.
,
Kashman
,
N.
,
Volland
,
G.
,
Weber
,
K.
,
Dowe
,
M.
, and
Rogers
,
S.
, 1985, “
Grip and Pinch Strength: Normative Data for Adults
,”
Arch. Phys. Med. Rehabil.
0003-9993,
66
(
2
), pp.
69
74
.
2.
Young
,
V. L.
,
Pin
,
P.
,
Kraemer
,
B. A.
,
Gould
,
R. B.
,
Nemergut
,
L.
, and
Pellowski
,
M.
, 1989, “
Fluctuation in Grip And Pinch Strength Among Normal Subjects
,”
J. Hand Surg. [Am]
0363-5023,
14
(
1
), pp.
125
129
.
3.
Su
,
C. Y.
,
Lin
,
J. H.
,
Chien
,
T. H.
,
Cheng
,
K. F.
, and
Sung
,
Y. T.
, 1994, “
Grip Strength in Different Positions of Elbow and Shoulder
,”
Arch. Phys. Med. Rehabil.
0003-9993,
75
(
7
), pp.
812
815
.
4.
Massy-Westropp
,
N.
,
Health
,
M.
,
Rankin
,
W.
,
Ahern
,
M.
,
Krishnan
,
J.
, and
Hearn
,
T. C.
, 2004, “
Measuring Grip Strength in Normal Adults: References Ranges and a Comparison of Electronic and Hydraulic Instruments
,”
J. Hand Surg. [Am]
0363-5023,
29
(
3
), pp.
514
519
.
5.
Voorbij
,
A. I. M.
, and
Steenbekkers
,
L. P. A.
, 2002, “
The Twisting Force of Aged Consumers When Opening a Jar
,”
Appl. Ergon
0003-6870,
33
, pp.
105
109
.
6.
Peebles
,
L.
, and
Norris
,
B.
, 2003, “
Filling in ‘Gaps’ in Strength Data for Design
,”
Appl. Ergon
0003-6870,
34
, pp.
73
88
.
7.
Wells
,
R.
, and
Grieg
,
M.
, 2001, “
Characterizing Human Hand Prehensile Strength by Force and Moment Wrench
,”
Ergonomics
0014-0139,
44
(
15
), pp.
1392
1402
.
8.
Grieg
,
M.
, and
Wells
,
R.
, 2004, “
Measurement of Prehensile Grasp Capabilities by a Force and Moment Wrench: Methodological Development and Assessment of Manual Workers
,”
Ergonomics
0014-0139,
47
(
47
), pp.
41
58
.
9.
Crawford
,
J. O.
,
Wanibe
,
E.
, and
Nayak
,
L.
, 2002, “
The Interaction Between Lid Diameter, Height and Shape on Wrist Torque Exertion in Younger and Older Adults
,”
Ergonomics
0014-0139,
45
(
13
), pp.
922
933
.
10.
Shivers
,
C. L.
,
Mirka
,
G. A.
, and
Kaber
,
D. B.
, 2002, “
Effect of Grip Span on Lateral Pinch Grip Strength
,”
Hum. Factors
0018-7208,
44
(
4
), pp.
569
577
.
11.
Neumann
,
D. A.
, 2003, “
The Carpometacarpal Joint of the Thumb: Stability, Deformity, and Therapeutic Intervention
,”
J. Orthop. Sports Phys. Ther.
0190-6011,
33
(
7
), pp.
386
399
.
12.
Green
,
D. P.
,
Hotchkiss
,
R. N.
,
Pederson
,
W. C.
, and
Wolfe
,
S. W.
, 2005,
Green’s Operative Hand Surgery
, 5th ed.,
Churchill Livingstone
, Philadelphia.
13.
Su
,
C.-Y.
,
Lin
,
J.-H.
,
Chien
,
T.-H.
,
Cheng
,
K.-F.
, and
Sung
,
Y.-T.
, 1994, “
Grip Strength in Different Positions of Elbow and Shoulder
,”
Arch. Phys. Med. Rehabil.
0003-9993,
75
, pp.
812
815
.
You do not currently have access to this content.