A new method is presented for measuring joint kinematics by optimally matching modeled trajectories of geometric surface models of bones with cine phase contrast (cine-PC) magnetic resonance imaging data. The incorporation of the geometric bone models (GBMs) allows computation of kinematics based on coordinate systems placed relative to full 3-D anatomy, as well as quantification of changes in articular contact locations and relative velocities during dynamic motion. These capabilities are additional to those of cine-PC based techniques that have been used previously to measure joint kinematics during activity. Cine-PC magnitude and velocity data are collected on a fixed image plane prescribed through a repetitively moved skeletal joint. The intersection of each GBM with a simulated image plane is calculated as the model moves along a computed trajectory, and cine-PC velocity data are sampled from the regions of the velocity images within the area of this intersection. From the sampled velocity data, the instantaneous linear and angular velocities of a coordinate system fixed to the GBM are estimated, and integration of the linear and angular velocities is used to predict updated trajectories. A moving validation phantom that produces motions and velocity data similar to those observed in an experiment on human knee kinematics was designed. This phantom was used to assess cine-PC rigid body tracking performance by comparing the kinematics of the phantom measured by this method to similar measurements made using a magnetic tracking system. Average differences between the two methods were measured as 2.82 mm rms for anterior∕posterior tibial position, and 2.63 deg rms for axial rotation. An inter-trial repeatability study of human knee kinematics using the new method produced rms differences in anterior∕posterior tibial position and axial rotation of 1.44 mm and 2.35 deg. The performance of the method is concluded to be sufficient for the effective study of kinematic changes caused to knees by soft tissue injuries.
Skip Nav Destination
Article navigation
October 2005
Technical Papers
A Method for Measurement of Joint Kinematics in Vivo by Registration of 3-D Geometric Models With Cine Phase Contrast Magnetic Resonance Imaging Data
Peter J. Barrance,
Peter J. Barrance
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716
Search for other works by this author on:
Glenn N. Williams,
Glenn N. Williams
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716
Search for other works by this author on:
John E. Novotny,
John E. Novotny
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716
Search for other works by this author on:
Thomas S. Buchanan
Thomas S. Buchanan
ASME Fellow
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716
Search for other works by this author on:
Peter J. Barrance
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716
Glenn N. Williams
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716
John E. Novotny
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716
Thomas S. Buchanan
ASME Fellow
Center for Biomedical Engineering Research,
Department of Mechanical Engineering
, 126 Spencer Laboratories, University of Delaware, Newark, DE 19716J Biomech Eng. Oct 2005, 127(5): 829-837 (9 pages)
Published Online: May 31, 2005
Article history
Received:
March 28, 2004
Revised:
May 19, 2005
Accepted:
May 31, 2005
Citation
Barrance, P. J., Williams, G. N., Novotny, J. E., and Buchanan, T. S. (May 31, 2005). "A Method for Measurement of Joint Kinematics in Vivo by Registration of 3-D Geometric Models With Cine Phase Contrast Magnetic Resonance Imaging Data." ASME. J Biomech Eng. October 2005; 127(5): 829–837. https://doi.org/10.1115/1.1992524
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Related Articles
A New Device for Measuring Knee Rotational Kinematics Using Magnetic Resonance Imaging
J. Med. Devices (December,2008)
Virtual Axis Finder: A New Method to Determine the Two Kinematic Axes of Rotation for the Tibio-Femoral Joint
J Biomech Eng (January,2010)
A MR Imaging Procedure to Measure Tarsal Bone Rotations
J Biomech Eng (December,2007)
Knee Joint Secondary Motion Accuracy Improved by Quaternion-Based Optimizer With Bony Landmark Constraints
J Biomech Eng (December,2010)
Related Proceedings Papers
Related Chapters
Experimental results
Ultrasonic Methods for Measurement of Small Motion and Deformation of Biological Tissues for Assessment of Viscoelasticity
Pseudoinverse Method and Singularities Discussed
Robot Manipulator Redundancy Resolution
Translations and Rotations Across the Knee Under Isometric Quadriceps Contraction
Skiing Trauma and Safety: Ninth International Symposium