Pulsatile flow fields in a cerebrovascular side-wall aneurysm model with a wide ostium after stenting are presented in terms of particle tracking velocimetry measurements and flow visualization. Among the stent parameters the shape, helix versus mesh, was selected to study its effect on the changes of intraaneurysmal hemodynamics for the reference of minimally invasive endovascular aneurysm treatment. The blocking ratio of the stents was fixed at 30%. The Womersley number was 3.9 and the mean, peak, and minimal Reynolds numbers based on the bulk average velocity and diameter of the parent vessel were 600, 850, and 300, respectively. Four consecutive flow-rate phases were selected to characterize the intra-aneurysmal flow. The results are characterized in terms of velocity vector field, regional average velocity, and intra-aneurysmal vorticity/circulation/wall shear stress. It is found that the hemodynamic features inside the aneurysm alter markedly with the shape of the stent and the size of the orifice. Both stents investigated induce favorable changes in the intra-aneurysmal flow stasis as well as direction and undulation of wall shear stresses. A comparison of the results of the helix to mesh stent shows that the former is more favorable for endovascular treatment.

1.
Dotter
,
C. T.
, and
Judkins
,
M. P.
,
1964
, “
Transluminal Treatment of Arteriosclerotic Obstruction: Description of a New Technique and a Preliminary Report of its Application
,”
Circulation
,
30
, pp.
654
670
.
2.
Liou
,
T. M.
,
Chang
,
W. C.
, and
Liao
,
C. C.
,
1997
, “
LDV Measurements in Lateral Model Aneurysms of Various Sizes
,”
Exp. Fluids
,
23
(
4
), pp.
317
324
.
3.
Liou
,
T. M.
, and
Liao
,
C. C.
,
1997
, “
Flowfields in lateral aneurysm models arising from parent vessels with different curvatures using PTV
,”
Exp. Fluids
,
23
(
4
), pp.
288
298
.
4.
Burleson
,
A. C.
,
Strother
,
C. M.
, and
Turitto
,
V. T.
,
1995
, “
Computer Modeling of Intracranial Saccular and Lateral Aneurysms for the Study of their Hemodynamics
,”
J. Neurosurg.
,
37
, pp.
774
784
.
5.
Lo¨w
,
M.
,
Perktold
,
K.
, and
Rauning
,
R.
,
1993
, “
Hemodynamics in Rigid and Distensible Saccular Aneurysms: a Numerical Study of Pulsatile Flow Characteristics
,”
Biorheology
,
30
, pp.
287
298
.
6.
Aenis
,
M.
,
Stancampiano
,
A. P.
,
Wakhloo
,
A. K.
, and
Lieber
,
B. B.
,
1997
, “
Modeking of Flow in a Straight Stented and Nonstented Side Wall Aneurysm Model
,”
ASME J. Biomech. Eng.
,
119
, pp.
206
212
.
7.
Lieber
,
B. B.
,
Livescu
,
V.
,
Hopkins
,
L. N.
, and
Wakhloo
,
A. K.
,
2002
, “
Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal Flow
,”
Ann. Biomed. Eng.
,
30
, pp.
768
777
.
8.
Marks
,
M. P.
,
Dake
,
M. D.
,
Steinberg
,
G. K.
,
Norbash
,
A. M.
, and
Lane
,
B.
,
1994
, “
Stent Placement for Arterial and Venous Cerebrovascular Disease: Preliminary Clinical Experience
,”
Radiology
,
191
, pp.
441
446
.
9.
Wakhloo
,
A. K.
,
Schellhammer
,
F.
,
Vries
,
J. D.
,
Haberstroh
,
J.
, and
Schumacher
,
M.
,
1994
, “
Self-Expanding and Balloon-Expandable Stents in the Treatment of Carotid Aneurysms: An Experimental Study in a Canine Model
,”
AJNR: Am. J. Neurosurg.
,
15
, pp.
493
502
.
10.
Hayashi
,
K.
,
Handa
,
H.
,
Nagasawa
,
S.
,
Okumura
,
A.
, and
Moritake
,
K.
,
1980
, “
Stiffness and Elastic Behavior of Human Intracranial and Extracranial Arteries
,”
J. Biomech.
,
13
, pp.
175
184
.
11.
Scott
,
S.
,
Ferguson
,
G. G.
, and
Roach
,
M. R.
,
1972
, “
Comparison of Elastic Properties of Human Intracranial Arteries and Aneurysm
,”
Can. J. Physiol. Pharmacol.
,
50
, pp.
328
332
.
12.
Liou
,
T. M.
, and
Liao
,
C. C.
,
1996
, “
Study of Pulsatile Flows in Lateral Aneurysm Models on a Straight Parent Vessel Using Particle Tracking Velocimetry
,”
J. Flow Vis. Image Process
,
3
(
3
), pp.
207
223
.
13.
Kingery, W. D., Bowen, H. K., and Uhlmann, D. R., 1976, Introduction to Ceramics, Wiley, New York.
14.
Nichols W., and O’Rourke M., 1990, McDonald’s blood flow in arterier, Lea & Febiger, Philadelphia, London.
15.
Gobin
,
Y. P.
,
Counord
,
J. L.
,
Flaud
,
P.
, and
Duffaux
,
J.
,
1994
, “
In Vitro Study of Haemodynamics in a Giant Saccular Aneurysm Model: Influence of Flow Dynamics in the Parent Vessel and Effects of Coil Embolisation
,”
Neuroradiology
,
36
, pp.
530
536
.
16.
Ferguson
,
G. G.
,
1972
, “
Physical Factors in the Initiation, Growth, and Rupture of Human Intracraninal Saccular Aneurysm
,”
J. Neurosurg.
,
37
, pp.
666
677
.
17.
Berry
,
J. L.
,
Santamarina
,
A.
,
Moore
, Jr.,
J. E.
,
Roychowdhury
,
S.
, and
Routh
,
W. D.
,
2000
, “
Experimental and Computational Flow Evaluation of Coronary Stents
,”
Ann. Biomed. Eng.
,
28
, pp.
386
398
.
18.
Crawford
,
T.
,
1959
, “
Some Observations of the Pathogenesis and Natural History of Intracranical Aneurysms
,”
J. Neurol., Neurosurg. Psychiatry
,
22
, pp.
259
266
.
19.
Graves
,
V. B.
,
Strother
,
C. M.
,
Partington
,
C. R.
, and
Rappe
,
A.
,
1992
, “
Flow Dynamics of Lateral Carotid Artery Aneurysms and their Effects on Coils and Balloons: an Experimental Study in Dogs
,”
AJNR Am. J. Neuroradiol.
,
13
, pp.
189
196
.
20.
Fry
,
D. L.
,
1968
, “
Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients
,”
Circ. Res.
,
22
, pp.
165
197
.
21.
Fry
,
D. L.
,
1969
, “
Certain Histological and Chemical Responses of the Vascular Interface to Acutely Induced Mechanical Stress in the Aorta of the Dog
,”
Circ. Res.
,
14
, pp.
93
108
.
22.
Gouzalez
,
C. F.
,
Cho
,
Y. I.
,
Ortega
,
H. V.
, and
Moret
,
J.
,
1992
, “
Intracranial Aneurysms: Flow Analysis of their Origin and Progression
,”
AJNR Am. J. Neuroradiol.
,
13
, pp.
181
188
.
23.
Crompton
,
M. R.
,
1964
, “
The Pathogenesis of Cerebral Infarction Following the Rupture of Cerebral Berry Aneurysms
,”
Brain
,
87
, pp.
491
510
.
24.
Suzuki
,
J.
, and
Ohara
,
H.
,
1978
, “
Clinicopathological Study of Cerebral Aneurysms: Origin, Rupture, and Growth
,”
J. Neurosurg.
,
48
, pp.
505
514
.
You do not currently have access to this content.