Blunt impact trauma to the patellofemoral joint during car accidents, sporting activities, and falls can produce a range of injuries to the knee joint, including gross bone fracture, soft tissue injury, and/or microinjuries to bone and soft tissue. Currently, the only well-established knee injury criterion applies to knee impacts suffered during car accidents. This criterion is based solely on the peak impact load delivered to seated cadavers having a single knee flexion angle. More recent studies, however, suggest that the injury potential, its location, and the characteristics of the damage are also a function of knee flexion angle and the stiffness of the impacting structure. For example, at low flexion angles, fractures of the distal patella are common with a rigid impact interface, while at high flexion angles splitting of the femoral condyles is more evident. Low stiffness impact surfaces have been previously shown to distribute impact loads over the anterior surface of the patella to help mitigate gross and microscopic injuries in the 90 deg flexed knee. The objective of the current study was to determine if a deformable impact interface would just as effectively mitigate gross and microscopic injuries to the knee at various flexion angles. Paired experiments were conducted on contralateral knees of 18 human cadavers at three flexion angles (60, 90, 120 deg). One knee was subjected to a fracture level impact experiment with a rigid impactor, and the opposite knee was impacted with a deformable interface (3.3 MPa crush strength honeycomb material) to the same load. This (deformable) impact interface was effective at mitigating gross bone fractures at approximately 5 kN at all flexion angles, but the frequency of split fracture of the femoral condyles may not have been significantly reduced at 120 deg flexion. On the other hand, this deformable interface was not effective in mitigating microscopic injuries observed for all knee flexion angles. These new data, in concert with the existing literature, suggest the chosen impact interface was not optimal for knee injury protection in that fracture and other minor injuries were still produced. For example, in 18 cadavers a total of 20 gross fractures and 20 subfracture injuries were produced with a rigid interface and 5 gross fractures and 21 subfracture injuries with the deformable interface selected for the current study. Additional studies will be needed to optimize the knee impact interface for protection against gross and microscopic injuries to the knee.
Skip Nav Destination
Article navigation
June 2001
Technical Papers
Impact Responses of the Flexed Human Knee Using a Deformable Impact Interface
Patrick J. Atkinson,
Patrick J. Atkinson
Orthopaedic Biomechanics Laboratories, Michigan State University, East Lansing, MI 48824
Department of Mechanical Engineering, Kettering University, Flint, MI 58504
Search for other works by this author on:
Roger C. Haut
Roger C. Haut
Orthopaedic Biomechanics Laboratories, Michigan State University, East Lansing, MI 48824
Search for other works by this author on:
Patrick J. Atkinson
Orthopaedic Biomechanics Laboratories, Michigan State University, East Lansing, MI 48824
Department of Mechanical Engineering, Kettering University, Flint, MI 58504
Roger C. Haut
Orthopaedic Biomechanics Laboratories, Michigan State University, East Lansing, MI 48824
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division May 18, 2000; revised manuscript received January 11, 2001. Associate Editor: C. H. Turner.
J Biomech Eng. Jun 2001, 123(3): 205-211 (7 pages)
Published Online: January 11, 2001
Article history
Received:
May 18, 2000
Revised:
January 11, 2001
Citation
Atkinson, P. J., and Haut, R. C. (January 11, 2001). "Impact Responses of the Flexed Human Knee Using a Deformable Impact Interface ." ASME. J Biomech Eng. June 2001; 123(3): 205–211. https://doi.org/10.1115/1.1372320
Download citation file:
Get Email Alerts
Improvement in Active Cell Proliferation Area at Higher Permeability With Novel TPMS Lattice Structure
J Biomech Eng (November 2024)
Modeling Fatigue Failure of Cartilage and Fibrous Biological Tissues Using Constrained Reactive Mixture Theory
J Biomech Eng (December 2024)
A Numerical Study of Crack Penetration and Deflection at the Interface Between Peritubular and Intertubular Dentin
J Biomech Eng (December 2024)
Related Articles
Chondrocyte Damage and Contact Pressures Following Impact on the Rabbit Tibiofemoral Joint
J Biomech Eng (August,2008)
Ankle Rehabilitation via Compliant Mechanisms
J. Med. Devices (June,2010)
The Axial Injury Tolerance of the Human Foot/Ankle Complex and the Effect of Achilles Tension
J Biomech Eng (December,2002)
An Analysis of the Effect of Lower Extremity Strength on Impact Severity During a Backward Fall
J Biomech Eng (December,2001)
Related Proceedings Papers
Related Chapters
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Safety
Engineering the Everyday and the Extraordinary: Milestones in Innovation
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design