This paper describes the design, evaluation, and application of a new system for quantifying two-dimensional collagen fiber orientation in soft tissue. Series of transmitted polarized light images were collected using a custom-designed macroscope. Combined analysis of pixel brightness, and hue from images collected with a compensator plate, permitted the assignment of each pixel into the appropriate orientation band. Experiments were performed to quantify the linearity and noise of the system. Validation was performed on a specimen composed of strain-birefringent plastic strips at various orientations. Preliminary collagen fiber orientation data is presented from a tendon specimen. This study demonstrates the utility of this approach for studying collagen fiber orientation across large areas.

1.
Aspden
R. M.
,
Bornstein
N. H.
, and
Hukins
D. W. L.
,
1987
, “
Collagen Organization in the Interspinous Ligament and Its Relationship to Tissue Function
,”
Journal of Anatomy
, Vol.
155
, pp.
141
151
.
2.
Chaudhuri
S.
,
Nguyen
H.
,
Rangayyan
R. M.
,
Walsh
S.
, and
Frank
C. B.
,
1987
, “
A Fourier Domain Directional Filtering Method for Analysis of Collagen Alignment in Ligaments
,”
IEEE Transactions on Biomedical Engineering
, Vol.
BME-34
(
7
), pp.
509
518
.
3.
Cochran
R. P.
,
Kunzelman
K. S.
,
Chuong
C. J.
,
Sacks
M. S.
, and
Eberhart
R. C.
,
1991
, “
Nondestructive Analysis of Mitral Valve Collagen Fibre Orientation
,”
ASAIO Transactions
, Vol.
37
(
3
), pp.
M447–M448
M447–M448
.
4.
Ehlers, E. G., 1987, Optical Mineralogy. Theory and Technique. Vol. 1, Blackwell Scientific Publications, Palo Alto, p. 29.
5.
Guido
S.
, and
Tranquillo
R. T.
,
1993
, “
A Methodology for the Systematic and Quantitative Study of Cell Contact Guidance in Oriented Collagen Gels—Correlation of Fibroblast Orientation and Gel Birefringence
,”
Journal of Cell Science
, Vol.
105
, pp.
317
331
.
6.
Jouk
P. S.
,
Usson
Y.
,
Michalowicz
G.
, and
Parazza
F.
,
1995
, “
Mapping of the Orientation of Myocardial Cells by Means of Polarized Light and Confocal Scanning Laser Microscopy
,”
Microscopy Research and Technique
, Vol.
30
, pp.
480
490
.
7.
Russ
J. C.
,
1992
, “
Image Processing to Correct Defects in Microscope Images
,”
Journal of Computer-Assisted Microscopy
, Vol.
4
(
2
), pp.
141
149
.
8.
Sacks
M. S.
, and
Chuong
C. J.
,
1992
, “
Characterization of Collagen Fiber Architecture in the Canine Diaphragmatic Central Tendon
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
114
, pp.
183
190
.
9.
Sacks
M. S.
,
Smith
D. B.
, and
Hiester
E. D.
,
1997
, “
A Small Angle Light Scattering Device for Planar Connective Tissue Microstructural Analysis
,”
Annals of Biomedical Engineering
, Vol.
25
, pp.
678
689
.
10.
Slayter, E. M., 1970, Optical Methods in Biology, Wiley, New York.
11.
Usson
Y.
,
Parazza
F.
,
Jouk
P. S.
, and
Michalowicz
G.
,
1994
, “
Method for the Study of the Three-Dimensional Orientation of the Nuclei of Myocardial Cells in Fetal Human Heart by Means of Confocal Scanning Laser Microscopy
,”
Journal of Microscopy
, Vol.
174
(
2
), pp.
101
110
.
12.
Whittaker
P.
,
Boughner
D. R.
, and
Kloner
R. A.
,
1991
, “
Role of Collagen in Acute Myocardial Infarct Expansion
,”
Circulation
, Vol.
84
(
5
), pp.
2123
2134
.
13.
Whittaker
P.
, and
Canham
P. B.
,
1991
, “
Demonstration of Quantitative Fabric Analysis of Tendon Collagen Using Two-Dimensional Polarized Light Microscopy
,”
Matrix
, Vol.
11
, pp.
56
62
.
This content is only available via PDF.
You do not currently have access to this content.