The goal of this study was to develop and validate a finite element model (FEM) for use in the design of a flooring system that would provide a stable walking surface during normal locomotion but would also deform elastically under higher loads, such as those resulting from falls. The new flooring system is designed to reduce the peak force on the femoral neck during a lateral fall onto the hip. The new flooring system is passive in nature and exhibits two distinct stiffnesses. During normal activities, the floor remains essentially rigid. Upon impact, the floor collapses and becomes significantly softer. The flooring system consists of a multitude of columns supporting a continuous walking surface. The columns were designed to remain stiff up to a specific load and, after exceeding this load, to deform elastically. The flooring returns to its original shape after impact. Part I of this study presented finite element and experimental results demonstrating that the floor deflection during normal walking remained less than 2 mm. To facilitate the floor’s development further, a nonlinear finite element model simulating the transient-impact response of a human hip against various floor configurations was developed. Nonlinearities included in the finite element models were: changing topology of deformable-body-to-deformable-body contact, snap-through buckling, soft tissue stiffness and damping, and large deformations. Experimental models developed for validating the finite element model included an anthropomorphic hip, an impact delivery mechanism, a data collection system, and four hand-fabricated floor tiles. The finite element model discussed in this study is shown to capture experimentally observed trends in peak femoral neck force reduction as a function of flooring design parameters. This study also indicates that a floor can be designed that deflects minimally during walking and reduces the peak force on the femoral neck during a fall-related impact by 15.2 percent.

1.
Casalena
J. A.
,
Badre–Alam
A.
,
Ovaert
T. C.
,
Cavanagh
P. R.
, and
Streit
D. A.
,
1998
, “
The Penn State Safety Floor: Part I—Design Parameters Associated With Walking Deflections
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
120
, this issue, pp.
517
525
.
1.
Courtney
A. C.
,
Wachtel
E. F.
,
Myers
E. R.
,
Cumming
N. M.
, and
Hayes
W. C.
,
1994
, “
Effects of Loading Rate on Strength of the Proximal Femur
,”
Calcified Tissue International
, Vol.
55
, No.
1
, pp.
53
58
2.
(published
erratum
appears in
Calcif. Tissue Int.
,
1994
,
55
(
5
):
402
402
).
1.
Courtney
A. C.
,
Wachtel
E. F.
,
Myers
E. R.
, and
Hayes
W. C.
,
1995
, “
Age-Related Reductions in the Strength of the Femur Tested in a Fall-Loading Configuration
,”
Journal of Bone & Joint Surgery—American Volume
,
77
(
3
), pp.
387
395
.
2.
Evans, F. G., 1970, “Impact Tolerance of Human Pelvic and Long Bones,” in: Gurdjian, E. S., Lange, W. A., Patrick, L. M., and Thomas, L. M., eds., Impact Injury and Crash Protection, Charles C. Thomas, Springfield, IL, pp. 402–417.
3.
Frankel, V. H., 1970, “Impact Tolerance of Human Pelvic and Long Bones; Discussion,” in: Gurdjian, E. S., Lange, W. A., Patrick, L. M., and Thomas, L. M., eds., Impact Injury and Crash Protection, Charles C. Thomas, Springfield, IL, pp. 418–420.
4.
Gehlsen
G. M.
, and
Whaley
M. H.
,
1990
, “
Falls in the Elderly: Part I, Gait
,”
Archives of Physical Medicine and Rehabilitation
, Vol.
71
, pp.
735
738
.
5.
Greenspan
S. L.
,
Myers
E. R.
,
Maitland
L. A.
,
Resnick
N. M.
, and
Hayes
W. C.
,
1994
, “
Fall Severity and Bone Mineral Density as Risk Factors for Hip Fracture in Ambulatory Elderly
,”
JAMA
,
271
(
2
), pp.
128
33
.
6.
Hayes, W. C., Myers, E. R., Morris, J. N., Rejda, S. A., Gerhart, T. N., Yett, H. S., and Lipsitz, L. A., 1990, “Fall Biomechanics as Determinants of Hip Fracture Risk,” Proc. 36th Annual Meeting of the Orthopædic Research Society, pp. 188.
7.
Jarnlo
G. B.
, and
Thorngren
K. G.
,
1993
, “
Background Factors to Hip Fractures
,”
Clinical Orthopedics and Related Research
, Vol.
287
, pp.
41
49
.
8.
Lauritzen
J. B.
, and
Askegaard
V.
,
1992
, “
Protection Against Hip Fractures by Energy Absorption
,”
Danish Medical Bulletin
, Vol.
39
, pp.
91
93
.
9.
Lauritzen
J. B.
,
Petersen
M. M.
, and
Lund
B.
,
1993
, “
Effect of External Hip Protectors on Hip Fractures
,”
Lancet
, Vol.
341
, pp.
11
13
.
10.
Lotz
J. C.
,
Cheal
E. J.
, and
Hayes
W. C.
,
1991
, “
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
112
, pp.
353
360
.
11.
Lotz
J. C.
, and
Hayes
W. C.
,
1990
, “
The Use of Quantitative Computed Tomography to Estimate Risk of Fracture of the Hip From Falls
,”
Journal of Bone and Joint Surgery
, Vol.
72A
, No.
5
, pp.
689
700
.
12.
Maki
B. E.
, and
Fernie
G. R.
,
1990
, “
Impact Attenuation of Floor Coverings in Simulated Falling Accidents
,”
Applied Ergonomics
, Vol.
21
No.
2
, pp.
107
114
.
13.
MARC Analysis, 1995, Element Library Users Guide, Vol. B. Palo Alto, CA.
14.
National Research Council and the Institute of Medicine, 1985, Injury in America, A Continuing Public Health Problem, Committee on Trauma Research, National Academy Press, Washington, DC, p. 41.
15.
Nevitt
M. C.
,
Cummins
S. R.
, and the
Study of Osteoporotic Fractures Research Group
,
1993
, “
Type of Fall and Risk of Hip and Wrist Fractures: The Study of Osteoporotic Fractures
,”
Journal of the American Geriatrics Society
, Vol.
41
, pp.
1226
1234
.
16.
Robinovitch, S. N., 1992, personal communication.
17.
Robinovitch
S. N.
,
Hayes
W. C.
, and
McMahon
T. A.
,
1995
, “
Energy-Shunting Hip Padding System Attenuates Femoral Impact Force in a Simulated Fall
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
117
, pp.
409
413
.
18.
van den Kroonenberg, A., Munih, P., Weigent-Hayes, M., and McMahon, T. A., 1993, “Hip Impact Velocities and Body Configurations for Experimental Falls From Standing Height,” Proc. 39th Annual Meeting of the Orthopedic Research Society, p. 24.
This content is only available via PDF.
You do not currently have access to this content.