A simple, inexpensive, and accurate way to measure relative segmental rotations resulting from torsional loadings locally is described. To measure these rotations, we fabricated a planar spatial linkage (open-loop kinematic chain) requiring only one rotational displacement transducer. This paper describes this device, defines its kinematics, and examines its accuracy.

1.
Bouvy
B. M.
,
Markel
M. D.
,
Chelikani
S. V.
,
Egger
E. L.
,
Piermattei
D. L.
, and
Vanderby
R.
,
1993
, “
Ex Vivo Biomechanics of Kirschner–Ehmer External Skeletal Fixation Applied to Canine Tibiae
,”
Veterinary Surgery
, Vol.
22
, No.
3
, pp.
194
207
.
2.
Brown
R. K.
,
Pelker
R. R.
,
Friedlaender
G. E.
,
Peschel
R. E.
, and
Panjabi
M. M.
,
1991
, “
Postfracture Irradiation Effects on the Biomechanical and Histologic Parameters of Fracture Healing
,”
Journal of Orthopaedic Research
, Vol.
9
, No.
6
, pp.
876
882
.
3.
Chao
E. Y. S.
,
Arc
H. T.
,
Lewallen
D. G.
, and
Kelly
P. J.
,
1989
, “
The Effect of Rigidity on Fracture Healing in External Fixation
,”
Clinical Orthopaedics and Related Research
, Vol.
241
, pp.
24
35
.
4.
Cole
K. J.
, and
Abbs
J. H.
,
1986
, “
Coordination of Three-Joint Digit Movements for Rapid Finger-Thumb Grasp
,”
Journal of Neurophysiology
, Vol.
55
, pp.
1406
1423
.
5.
Crisco
J. J.
,
Oda
T.
,
Panjabi
M. M.
, and
Bueff
H. U.
,
1991
a, “
Transections of the C1–C2 Joint Capsular Ligaments in the Cadaveric Spine
,”
Spine
, Vol.
16
, No.
10S
, pp.
S474–S479
S474–S479
.
6.
Crisco
J. J.
,
Panjabi
M. M.
, and
Dvorak
J.
,
1991
b, “
A Model of the Alar Ligaments of the Upper Cervical Spine in Axial Rotation
,”
Journal of Biomechanics
, Vol.
24
, No.
7
, pp.
607
614
.
7.
Hefzy
M. S.
, and
Grood
E. S.
,
1986
, “
Sensitivity of Insertion Locations on Length Patterns of Anterior Cruciate Ligament Fibers
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
108
, pp.
73
82
.
8.
Kohles
S. S.
,
Markel
M. D.
,
Rock
M. G.
,
Chao
E. Y. S.
, and
Vanderby
R.
,
1994
, “
Mechanical Evaluation of Six Types of Reconstruction Following 25,50, and 75% Resection of the Proximal Femur
,”
Journal of Orthopaedic Research
, Vol.
12
, pp.
834
843
.
9.
Kohles
S. S.
,
Marlsel
M. D.
,
Rock
M. G.
,
Chou
E. Y. S.
, and
Vanderby
R.
,
1996
, “
Fixation of Femoral Allograft/Prosthesis Composites After 25%, 50% and 75% Resection
,”
Medical Engineering & Physics
, Vol.
18
, No.
2
, pp.
115
121
.
10.
Kunz
D. N.
,
McCabe
R. P.
,
Zdeblicis
T. A.
, and
Vanderby
R.
,
1994
, “
A Multi-Degree of Freedom System for Biomechanical Testing
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
116
, No.
3
, pp.
371
373
.
11.
Lewis
J. L.
,
Lew
W. D.
, and
Schmidt
J.
,
1988
, “
Description and Error Evaluation of an In Vitro Knee Joint Testing System
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
110
, No.
3
, pp.
238
248
.
12.
Liu
W.
, and
Panjabi
M. M.
,
1996
, “
On Improving the Accuracy of Instrumented Spatial Linkage System
,”
Journal of Biomechanics
, Vol.
29
, No.
10
, pp.
1383
1385
.
13.
Oxland
T. R.
,
Crisco
J. J.
,
Panjabi
M. M.
, and
Yamamoto
I.
,
1992
, “
The Effect of Injury on Rotational Coupling at the Lumbosacral Joint: A Biomechanical Investigation
,”
Spine
, Vol.
17
, No.
1
, pp.
74
80
.
14.
Soni
A. H.
,
Sullivan
J. A.
,
Patwardhan
A. G.
,
Gudavalli
M. R.
, and
Chitwood
J.
,
1982
, “
Kinematic Analysis and Simulation of Vertebral Motion Under Static Load: Part I—Kinematic Analysis
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
104
, pp.
105
111
.
15.
Stone, H. W., 1987, Kinematic Modeling, Identification, and Control of Robotic Manipulators, Boston, Kluwer Academic Publishers.
16.
Thomas, D. H., and Long, C., 1964, “An Electrogoniometer for the Finger,” American Journal of Medical Electronics, pp. 96–100.
17.
Trostle
S. S.
,
Wilson
D. G.
,
Dueland
R. T.
, and
Markel
M. D.
,
1995
, “
In Vitro Biomechanical Comparison of Solid and Tubular Interlocking Nails in Neonatal Bovine Femurs
,”
Veterinary Surgery
, Vol.
24
, No.
3
, pp.
235
243
.
18.
Weinhoffer
S. L.
,
Barnes
S. Z.
, and
Berme
N.
,
1993
, “
Measurement of Angular Displacements Using Hall Effect Transducers
,”
Journal of Biomechanics
, Vol.
26
, No.
4/5
, pp.
609
612
.
19.
Zdeblick
T.
,
Wilson
D.
,
Cooke
M.
,
Kunz
D.
,
McCabe
R.
,
Ulm
M.
, and
Vanderby
R.
,
1992
, “
Anterior Cervical Discectomy and Fusion: A Comparison of Techniques in an Animal Model
,”
Spine
, Vol.
17
, No.
10S
, pp.
S418–S426
S418–S426
.
This content is only available via PDF.
You do not currently have access to this content.