Flow patterns generated during ventricular filling have been investigated for three different combinations of flow rate and injection volume. The numerical solutions from a commercially available computational fluid dynamics package were compared with observations made under identical flow conditions in a physical model for the purpose of code validation. Particle pathlines were generated from the numerical velocity data and compared with corresponding flow-visualization pictures. A vortex formed at the inlet to the ventricle in both cases: During the filling phase, the vortex expanded and traveled toward the apex of the ventricle until, at the end of filling, the vortex occupied the full radial extent of the ventricle; the vortex continued to travel once the filling process had ended. The vortices in vitro were more circular in shape and occupied a smaller volume than those generated by the numerical model. Nevertheless, comparison of the trajectories of the vortex centres showed that there was good agreement for the three conditions studied. Postprocessing of velocity data from the numerical solution yielded wall shear-stress measurements and particle pathlines that clearly illustrate the mass-transport qualities of the traveling vortex structure. For the cases considered here, the vortex transit produced a time-dependent shear stress distribution that had a peak value of 20 dynes cm−2, with substantially lower levels of shear stress in those regions not reached by the traveling vortex. We suggest that vortex formation and travel could reduce the residence time of fluid within a skeletal muscle ventricle, provided that the vortex travels the complete length of the ventricle before fluid is ejected at the start of the next cycle.

1.
Salmons
S.
, and
Sre´ter
F. A.
, “
Significance of Impulse Activity in the Transformation of Skeletal Muscle Type
,”
Nature
, Vol.
263
,
1976
, pp.
30
34
.
2.
Acker
M. A.
,
Anderson
W. A.
,
Hammond
R. L.
,
Mannion
J. D.
,
Salmons
S.
, and
Stephenson
L. W.
, “
Skeletal Muscle as a Potential Power Source for a Cardiovascular Pump: Assessment in vivo
,”
Science
, Vol.
236
,
1987
, pp.
324
327
.
3.
Henry, F. S., and Collins, M. W., “Numerical Methods for Blood Flow,” Advances in Haemodynamics and Haemorheology, T. V. How, ed., JAI Press, pp. 67–112.
4.
Perktold
K.
, and
Resch
M.
, “
Numerical Flow Studies in Human Carotid Bifurcations: Basic Discussion of the Geometric Factor in Atherogenesis
,”
J. Biomed. Engng.
, Vol.
12
,
1990
, pp.
111
123
.
5.
Henry
F. S.
,
Hughes
P. E.
,
How
T. V.
, and
Collins
M. W.
, “
Numerical Investigation of the Flow in Proximal and Distal End-to-Side Anastomoses
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
118
,
1996
, pp.
302
317
.
6.
Tutty
O. R.
, “
Pulsatile Flow in a Constricted Channel
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
, Vol.
114
,
1992
, pp.
50
54
.
7.
Henry, F. S., and Collins, M. W., “Computations of Flow Distal of Axisymmetric and Asymmetric Stenoses,” J. M. Tarbell, ed., 1993 Advances in Bioengineering, ASME BED-Vol. 26, 1993, pp. 87–90.
8.
Reuderink, P. J., “Analysis of the Flow in a 3D Distensible Model of the Carotid Artery Bifurcation,” Ph.D. Thesis, Eindhoven University of Technology, the Netherlands, 1991.
9.
Peskin
C. S.
, and
McQueen
D. M.
, “
Cardiac Fluid Dynamics
,”
Crit. Rev. in Biomed. Eng.
, Vol.
20
,
1992
, pp.
451
459
.
10.
Henry, F. S., and Collins, M. W., “A Novel Predictive Model With Compliance for Arterial Flows,” J. M. Tarbell, ed., 1993 Advances in Bioengineering, ASME BED-Vol. 26, 1993, pp. 131–135.
11.
Burns, A. D., and Wilkes, N. S., “A Finite Difference Method for the Computation of Fluid Flows in Complex 3D Geometries,” UK AEA report, 1987 (AERA Harwell).
12.
Xu
X. Y.
, and
Collins
M. W.
, “
A Review of the Numerical Analysis of Blood Flow in Arterial Bifurcations
,”
Proc. Instn. Mech. Engrs., Journal of Engineering in Medicaine
, Vol.
204
, Part H,
1990
, pp.
205
216
.
13.
Shortland
A. P.
,
Black
R. A.
,
Jarvis
J. C.
, and
Salmons
S.
, “
A Novel Video Technique for Visualizing Flows in Cardiovascular Models
,”
J. Biomech.
, Vol.
29
, pp.
239
244
.
14.
Shortland
A. P.
,
Black
R. A.
,
Jarvis
J. C.
,
Henry
F. S.
,
Iudicello
F.
,
Collins
M. W.
, and
Salmons
S.
, “
Formation and Travel of Vortices in Model Ventricles: Application to the Design of Skeletal Muscle Ventricles
,”
J. Biomech.
, Vol.
29
, No.
4
, pp.
503
511
.
15.
Henry, F. S., Iudicello, F., Shortland, A., Jarvis, J. C., Black, R. A., Collins, M. W., and Salmons, S., “Modelling Wall-Driven Cardiovascular Flows,” M. J. Askew, ed., 1994 Advances in Bioengineering, ASME BED-Vol. 28, 1994, pp. 399–400.
16.
Hashimoto
S.
,
Maeda
H.
, and
Sasada
T.
, “
Effect of Shear Rate on Clot Growth at Foreign Surfaces
,”
Artif. Organs
, Vol.
9
,
1985
, pp.
345
50
.
17.
Hubbell
J. A.
, and
McIntire
L. V.
, “
Visualization and Analysis of Mural Thrombogenesis on Collagen, Polyurethane and Nylon
,”
Biomaterials
, Vol.
7
,
1986
, pp.
354
63
.
This content is only available via PDF.