A mechanical linkage with electro-magnetic sensors (a displacement transducer) is described, which may be used to measure accurately the relative motion at a bony junction such as a fracture. The linkage may be fixed to bone screws of externally-fixated fractures during routine patient activity, to measure three-dimensional inter fragmentary displacements arising from dynamic loading. Movements of the linkage are monitored by six Hall Effect devices for the six degrees of freedom (three orthogonal translations and three rotations about the translating axes). Measurements are made within error bounds of ±0.025 mm and ±0.025 deg over a range of 5 mm for the two orthogonal transverse translations, 8 mm for axial translation and 8 deg for the three rotations. Movements at the linkage, remote from the fracture, are then translated mathematically to the fracture site, assuming rigid screw contact with the bone. Displacements of the distal fragment in relation to the proximal, at the fracture center, can then be expressed anatomically through anterior, medial, and distal translations, and rotations in the sagittal, coronal, or transverse planes.
Skip Nav Destination
Article navigation
November 1996
Technical Papers
An Instrumented Spacial Linkage for Monitoring Relative Three-Dimensional Motion Between Fracture Fragments
T. N. Gardner,
T. N. Gardner
Oxford Orthopaedic Engineering Centre, University of Oxford, Nuffield Orthopaedic Centre, Windmili Road, Headington, Oxford, United Kingdom
Search for other works by this author on:
M. Evans,
M. Evans
Oxford Orthopaedic Engineering Centre, University of Oxford, Nuffield Orthopaedic Centre, Windmili Road, Headington, Oxford, United Kingdom
Search for other works by this author on:
P. J. Kyberd
P. J. Kyberd
Oxford Orthopaedic Engineering Centre, University of Oxford, Nuffield Orthopaedic Centre, Windmili Road, Headington, Oxford, United Kingdom
Search for other works by this author on:
T. N. Gardner
Oxford Orthopaedic Engineering Centre, University of Oxford, Nuffield Orthopaedic Centre, Windmili Road, Headington, Oxford, United Kingdom
M. Evans
Oxford Orthopaedic Engineering Centre, University of Oxford, Nuffield Orthopaedic Centre, Windmili Road, Headington, Oxford, United Kingdom
P. J. Kyberd
Oxford Orthopaedic Engineering Centre, University of Oxford, Nuffield Orthopaedic Centre, Windmili Road, Headington, Oxford, United Kingdom
J Biomech Eng. Nov 1996, 118(4): 586-594 (9 pages)
Published Online: November 1, 1996
Article history
Received:
February 7, 1992
Revised:
September 13, 1995
Online:
October 30, 2007
Citation
Gardner, T. N., Evans, M., and Kyberd, P. J. (November 1, 1996). "An Instrumented Spacial Linkage for Monitoring Relative Three-Dimensional Motion Between Fracture Fragments." ASME. J Biomech Eng. November 1996; 118(4): 586–594. https://doi.org/10.1115/1.2796048
Download citation file:
Get Email Alerts
Related Articles
High Speed Fracture Fixation: Assessing Resulting Fixation Stability and Fastener Withdrawal Strength
J Biomech Eng (September,2013)
Factors Affecting the Pullout Strength of Cancellous Bone Screws
J Biomech Eng (August,1996)
The Effect of Screw Pullout Rate on Screw Purchase in Synthetic Cancellous Bone
J Biomech Eng (February,2009)
An Articulating Tool for Endoscopic Screw Delivery
J. Med. Devices (June,2010)
Related Proceedings Papers
Related Chapters
A Mechanism of Intergranular Fracture During High-Temperature Fatigue
Fatigue Mechanisms
Timebase Plots
Fundamentals of Rotating Machinery Diagnostics
Polar, Bode, and APHT Plots
Fundamentals of Rotating Machinery Diagnostics