The use of pulsed blood flow in membrane plasmapheresis permits enhancement of plasma filtration yet may result in high levels of hemolysis due to large increases in instantaneous transmembrane pressure (TMP). This work investigates the occurrence of hemolysis as a function of TMP and wall shear rates (γw) for both steady and pulsed blood flow conditions. Two types of hollow fiber filters with identical polypropylene membranes but different lengths and membrane areas (0.1 and 0.25 m2) were tested. Fresh citrated bovine blood was circulated through the fibers at various blood flowrates and TMP in a single pass circuit using a pulsation generator, made of a single roller peristaltic pump. The free hemoglobin concentration of the plasma, Hbm, was measured from permeate samples collected at each set of TMP and γw conditions. It was found that the net hemolysis generated by the filtration was proportional to the membrane area. This justified the introduction of an hemolysis index, IH, equal to the plasma hemoglobin per unit membrane area. The boundary for the occurrence of hemolysis was thus defined by setting IH = 30 mg/ dl.m2. For both steady and pulsed flow conditions the hemolysis boundaries were found to be straight lines in the TMP-γw plane. They were identical for the two filters under steady flow but different for pulsed flow. At the same time mean wall shear rates hemolysis occurred at a lower time mean TMP under pulsed flow conditions than under steady flow conditions.
Skip Nav Destination
Article navigation
November 1994
Research Papers
Hemolysis During Membrane Plasma Separation With Pulsed Flow Filtration Enhancement
Jane L. Philp,
Jane L. Philp
Department of Biological Engineering, University of Compiegne, Compiegne, France BP 649 60206
Search for other works by this author on:
Michel Y. Jaffrin,
Michel Y. Jaffrin
Department of Biological Engineering, University of Compiegne, Compiegne, France BP 649 60206
Search for other works by this author on:
Luhui Ding
Luhui Ding
Department of Biological Engineering, University of Compiegne, Compiegne, France BP 649 60206
Search for other works by this author on:
Jane L. Philp
Department of Biological Engineering, University of Compiegne, Compiegne, France BP 649 60206
Michel Y. Jaffrin
Department of Biological Engineering, University of Compiegne, Compiegne, France BP 649 60206
Luhui Ding
Department of Biological Engineering, University of Compiegne, Compiegne, France BP 649 60206
J Biomech Eng. Nov 1994, 116(4): 514-520 (7 pages)
Published Online: November 1, 1994
Article history
Received:
May 18, 1993
Revised:
November 12, 1993
Online:
March 17, 2008
Citation
Philp, J. L., Jaffrin, M. Y., and Ding, L. (November 1, 1994). "Hemolysis During Membrane Plasma Separation With Pulsed Flow Filtration Enhancement." ASME. J Biomech Eng. November 1994; 116(4): 514–520. https://doi.org/10.1115/1.2895803
Download citation file:
Get Email Alerts
Cited By
Related Articles
High Throughput Cell-Free Extraction of Plasma by an Integrated Microfluidic Device Combining Inertial Focusing and Membrane
J. Heat Transfer (May,2017)
Ingredient-Wise Study of Flux Characteristics in the Ceramic Membrane Filtration of Uncontaminated Synthetic Metalworking Fluids, Part 1: Experimental Investigation of Flux Decline
J. Manuf. Sci. Eng (November,2000)
Elementary Mechanics of the Endothelium of Blood Vessels
J Biomech Eng (February,1993)
Related Proceedings Papers
Related Chapters
Concluding remarks
Mechanical Blood Trauma in Circulatory-Assist Devices
Application Analysis and Experimental Study on Performance of Energy-Saving Electret Fiber
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices