Atherosclerosis, thrombosis, and intimal hyperplasia are major forms of cardiovascular diseases in the United States. Previous studies indicate a significant correlation between hemodynamics, in particular, wall shear rate, and pathology of the arterial walls. While results of these studies implicate morphologic and functional changes related to wall shear rate magnitude, a standard technique for wall shear rate measurement has not been established. In this study, theoretical and in-vitro experimental fully developed steady and physiologic pulsatile flow waveforms have been used to obtain velocity profiles in the near-wall region. The estimated wall shear rates from these results are compared to the theoretical value to assess the accuracy of the approximating technique. Experimentally obtained results from LDA suggest that in order to minimize the error in velocity data, and subsequently, the wall shear rate, the first measured velocity has to be 500 μm away from the wall. While a linear approximation did not produce errors larger than 16.4 percent at peak systole, these errors substantially increased as the velocity magnitudes decreased during late systole and diastole. Overall, a third degree polynomial curve fit using four points produced the most accurate estimation of wall shear rate through out the cardiac cycle. Results of higher degree curve-fitting functions can be unpredictable due to potential oscillations of the function near the wall. Hence, based on the results of this study, use of a linear approximation is not recommended; a third degree curve-fitting polynomial, using four points provided the most accurate approximation for these flow waveforms.
Skip Nav Destination
Article navigation
August 1994
Research Papers
Derivation of Shear Rates From Near-Wall LDA Measurements Under Steady and Pulsatile Flow Conditions
Ray S. Fatemi,
Ray S. Fatemi
Department of Biomedical Engineering, The University of Akron, Akron, OH 44325-0302
Search for other works by this author on:
Stanley E. Rittgers
Stanley E. Rittgers
Vascular Hemodynamics Research Lab, Summa Health Systems, Akron, OH 44309
Search for other works by this author on:
Ray S. Fatemi
Department of Biomedical Engineering, The University of Akron, Akron, OH 44325-0302
Stanley E. Rittgers
Vascular Hemodynamics Research Lab, Summa Health Systems, Akron, OH 44309
J Biomech Eng. Aug 1994, 116(3): 361-368 (8 pages)
Published Online: August 1, 1994
Article history
Received:
September 14, 1992
Revised:
September 28, 1993
Online:
March 17, 2008
Citation
Fatemi, R. S., and Rittgers, S. E. (August 1, 1994). "Derivation of Shear Rates From Near-Wall LDA Measurements Under Steady and Pulsatile Flow Conditions." ASME. J Biomech Eng. August 1994; 116(3): 361–368. https://doi.org/10.1115/1.2895743
Download citation file:
Get Email Alerts
Related Articles
Vascular Cell Adhesion Molecule-1 Expression in Endothelial Cells Exposed to Physiological Coronary Wall Shear Stresses
J Biomech Eng (August,2009)
Preliminary Analysis of the Effects of Blood Vessel Movement on Blood Flow Patterns in the Coronary Arteries
J Biomech Eng (August,1994)
Related Proceedings Papers
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Introduction
Modified Detrended Fluctuation Analysis (mDFA)
Occlusion Identification and Relief within Branched Structures
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling