We have reviewed highlights of the research in trabecular bone biomechanics performed over the past 20 years. Results from numerous studies have shown that trabecular bone is an extremely heterogeneous material—modulus can vary 100-fold even within the same metaphysis—with varying degrees of anisotropy. Strictly speaking, descriptions of the mechanical properties of trabecular bone should therefore be accompanied by specification of factors such as anatomic site, loading direction, and age. Research efforts have also been focused on the measurement of mechanical properties for individual trabeculae, improvement of methods for mechanical testing at the continuum level, quantification of the three-dimensional architecture of trabecular bone, and formulation of equations to relate the microstructural and continuum-level mechanical properties. As analysis techniques become more sophisticated, there is now evidence that factors such as anisotropy and heterogeneity of individual trabeculae might also have a significant effect on the continuum-level properties, suggesting new directions for future research. Other areas requiring further research are the time-dependent and multiaxial failure properties at the continuum level, and the stiffness and failure properties at the lamellar level. Continued research in these areas should enhance our understanding of issues such as age-related bone fracture, prosthesis loosening, and bone remodeling.
Skip Nav Destination
Article navigation
November 1993
Research Papers
A 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Tony M. Keaveny,
Tony M. Keaveny
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, 330 Brookline Ave., Boston, MA 02215
Search for other works by this author on:
Wilson C. Hayes
Wilson C. Hayes
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, 330 Brookline Ave., Boston, MA 02215
Search for other works by this author on:
Tony M. Keaveny
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, 330 Brookline Ave., Boston, MA 02215
Wilson C. Hayes
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, 330 Brookline Ave., Boston, MA 02215
J Biomech Eng. Nov 1993, 115(4B): 534-542 (9 pages)
Published Online: November 1, 1993
Article history
Revised:
August 10, 1993
Online:
March 17, 2008
Citation
Keaveny, T. M., and Hayes, W. C. (November 1, 1993). "A 20-Year Perspective on the Mechanical Properties of Trabecular Bone." ASME. J Biomech Eng. November 1993; 115(4B): 534–542. https://doi.org/10.1115/1.2895536
Download citation file:
Get Email Alerts
Related Articles
Poly(Propylene Fumarate)–Hydroxyapatite Nanocomposite Can Be a Suitable Candidate for Cervical Cages
J Biomech Eng (October,2018)
Regional Variations of HR-pQCT Morphological and Biomechanical Measurements of Bone Segments and Their Associations With Whole Distal Radius and Tibia Mechanical Properties
J Biomech Eng (September,2019)
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
Mathematical Background
Vibrations of Linear Piezostructures
Anisotropy and Mechanical Properties
New Advanced High Strength Steels: Optimizing Properties