Flow visualization and wall pressure measurements were made in a polyurethane cast of a cadaver coronary artery with a significant “s” shaped reverse curvature. A sucrose solution was used to simulate the kinematic viscosity of blood, with flow rates in the physiologic range. Flow visualization demonstrated significant secondary flow patterns in the wall vicinity, which increased with increasing Reynolds number. Random dye dispersion was observed at a Reynolds number of about 400, but not at 200. Dye filament patterns in the transition between the first and second curved region were predominantly influenced by the second curved region at lower Reynolds numbers, and by the first curved region at higher Re. Local wall pressure measurements demonstrated a significant centrifugal effect with large radial pressure differences across the casting. Flow resistances for the casting were considerably greater than reference Poiseuille flow values, and increased further with pulsatile flow.
Skip Nav Destination
Article navigation
Research Papers
Flow Measurements in a Highly Curved Atherosclerotic Coronary Artery Cast of Man
L. H. Back,
L. H. Back
Jet propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109
Search for other works by this author on:
T. K. Liem,
T. K. Liem
University of Southern California School of Medicine, Los Angeles, CA 90033
Search for other works by this author on:
E. Y. Kwack,
E. Y. Kwack
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109
Search for other works by this author on:
D. W. Crawford
D. W. Crawford
Department of Medicine, Cardiology Division, University of Southern California, Los Angeles, CA 90033
Search for other works by this author on:
L. H. Back
Jet propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109
T. K. Liem
University of Southern California School of Medicine, Los Angeles, CA 90033
E. Y. Kwack
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109
D. W. Crawford
Department of Medicine, Cardiology Division, University of Southern California, Los Angeles, CA 90033
J Biomech Eng. May 1992, 114(2): 232-240 (9 pages)
Published Online: May 1, 1992
Article history
Received:
December 10, 1990
Revised:
October 10, 1991
Online:
March 17, 2008
Citation
Back, L. H., Liem, T. K., Kwack, E. Y., and Crawford, D. W. (May 1, 1992). "Flow Measurements in a Highly Curved Atherosclerotic Coronary Artery Cast of Man." ASME. J Biomech Eng. May 1992; 114(2): 232–240. https://doi.org/10.1115/1.2891377
Download citation file:
Get Email Alerts
Effect of Collagen Fiber Tortuosity Distribution on the Mechanical Response of Arterial Tissues
J Biomech Eng (February 2025)
Related Articles
Flow Measurements in an Aortocoronary Bypass Graft Casting
J Biomech Eng (May,1996)
Effect of Mild Atherosclerosis on Flow Resistance in a Coronary Artery Casting of Man
J Biomech Eng (February,1984)
Flow Measurements in a Human Femoral Artery Model With Reverse Lumen Curvature
J Biomech Eng (November,1988)
Flow Measurements in an Atherosclerotic Curved, Tapered Femoral Artery Model of Man
J Biomech Eng (November,1988)
Related Proceedings Papers
Related Chapters
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Hemolysis
Mechanical Blood Trauma in Circulatory-Assist Devices