Over 90 percent of the more than 250,000 hip fractures that occur annually in the United States are the result of falls from standing height. Despite this, the stresses associated with femoral fracture from a fall have not been investigated previously. Our objectives were to use three-dimensional finite element models of the proximal femur (with geometries and material properties based directly on quantitative computed tomography) to compare predicted stress distributions for one-legged stance and for a fall to the lateral greater trochanter. We also wished to test the correspondence between model predictions and in vitro strain gage data and failure loads for cadaveric femora subjected to these loading conditions. An additional goal was to use the model predictions to compare the sensitivity of several imaging sites in the proximal femur which are used for the in vivo prediction of hip fracture risk. In this first of two parts, linear finite element models of two unpaired human cadaveric femora were generated. In Part II, the models were extended to include nonlinear material properties for the cortical and trabecular bone. While there was poor correspondence between strain gage data and model predictions, there was excellent agreement between the in vitro failure data and the linear model, especially using a von Mises effective strain failure criterion. Both the onset of structural yielding (within 22 and 4 percent) and the load at fracture (within 8 and 5 percent) were predicted accurately for the two femora tested. For the simulation of one-legged stance, the peak stresses occurred in the primary compressive trabeculae of the subcapital region. However, for a simulated fall, the peak stresses were in the intertrochanteric region. The Ward’s triangle (basicervical) site commonly used for the clinical assessment of osteoporosis was not heavily loaded in either situation. These findings suggest that the intertrochanteric region may be the most sensitive site for the assessment of fracture risk due to a fall and the subcapital region for fracture risk due to repetitive activities such as walking.
Skip Nav Destination
Article navigation
November 1991
Research Papers
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
J. C. Lotz,
J. C. Lotz
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, Boston, MA 02215
Search for other works by this author on:
E. J. Cheal,
E. J. Cheal
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, Boston, MA 02215
Search for other works by this author on:
W. C. Hayes
W. C. Hayes
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, Boston, MA 02215
Search for other works by this author on:
J. C. Lotz
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, Boston, MA 02215
E. J. Cheal
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, Boston, MA 02215
W. C. Hayes
Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Charles A. Dana Research Institute, Beth Israel Hospital and Harvard Medical School, Boston, MA 02215
J Biomech Eng. Nov 1991, 113(4): 353-360 (8 pages)
Published Online: November 1, 1991
Article history
Received:
November 5, 1989
Revised:
April 15, 1991
Online:
March 17, 2008
Citation
Lotz, J. C., Cheal, E. J., and Hayes, W. C. (November 1, 1991). "Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis." ASME. J Biomech Eng. November 1991; 113(4): 353–360. https://doi.org/10.1115/1.2895412
Download citation file:
Get Email Alerts
Related Articles
Osteoporotic Hip Fracture Prediction: Is T-Score-Based Criterion Enough? A Hip Structural Analysis-Based Model
J Biomech Eng (November,2018)
PMMA Implants Increase Femoral Strength
J. Med. Devices (June,2008)
Development of an Inertia-Driven Model of Sideways Fall for Detailed Study of Femur Fracture Mechanics
J Biomech Eng (December,2013)
Related Proceedings Papers
Related Chapters
Radial Delayed Hydride Cracking in Irradiated Zircaloy-2 Cladding: Advanced Characterization Techniques
Zirconium in the Nuclear Industry: 20th International Symposium
Compromise between Tensile and Fatigue Strength
New Advanced High Strength Steels: Optimizing Properties
In Situ Observations of the Failure Mechanisms of Hydrided Zircaloy-4
Zirconium in the Nuclear Industry: 20th International Symposium