An acoustic transducer design to measure the relative translations and rotations across the knee with no mechanical coupling between the tibia and femur is presented. Platforms attached to femoral and tibial tracking fixtures hold acoustic sources and receivers, respectively. The distance from each source to each receiver is measured by the acoustic transit time and the translations and rotations across the knee joint are computed. For rotations less than 30 deg around the expected operating position, the resolution of the transducer is 0.3 deg; for translations less than 1.5 cm around the expected operating position, the resolution is 0.03 cm. Theoretical error analysis using a Monte Carlo method shows that the uncertainty in the measurement depends on the relative position of the sources and receivers. The analysis predicts the worst case resolution of the transducer as 0.09 cm in translation and 0.6 deg in rotation when the receiver platform is translated 8.0 cm parallel to the source platform. The transducer and fixturing system are demonstrated on a cadaver specimen for applied anterior force and applied internal-external rotation. Errors due to (soft tissue) motion of the transducer relative to the bone during in vivo measurements are assessed on the cadaver specimen. For internal-external rotation the error due to soft tissue motion is a maximum of 0.5 cm in translation and 1.8 deg in rotation. For applied anterior force the error due to soft tissue motion is a maximum of 0.16 cm in translation and 2.7 deg in rotation.
Skip Nav Destination
Article navigation
November 1990
Research Papers
A Six-Degree-of-Freedom Acoustic Transducer for Rotation and Translation Measurements Across the Knee
T. P. Quinn,
T. P. Quinn
Department of Mechanical Engineering, University of California, Berkeley, CA 94720
Search for other works by this author on:
C. D. Mote, Jr.
C. D. Mote, Jr.
Department of Mechanical Engineering, University of California, Berkeley, CA 94720
Search for other works by this author on:
T. P. Quinn
Department of Mechanical Engineering, University of California, Berkeley, CA 94720
C. D. Mote, Jr.
Department of Mechanical Engineering, University of California, Berkeley, CA 94720
J Biomech Eng. Nov 1990, 112(4): 371-378 (8 pages)
Published Online: November 1, 1990
Article history
Received:
July 24, 1989
Revised:
July 18, 1990
Online:
March 17, 2008
Citation
Quinn, T. P., and Mote, C. D., Jr. (November 1, 1990). "A Six-Degree-of-Freedom Acoustic Transducer for Rotation and Translation Measurements Across the Knee." ASME. J Biomech Eng. November 1990; 112(4): 371–378. https://doi.org/10.1115/1.2891199
Download citation file:
Get Email Alerts
Cited By
Related Articles
Virtual Axis Finder: A New Method to Determine the Two Kinematic Axes of Rotation for the Tibio-Femoral Joint
J Biomech Eng (January,2010)
Knee Joint Secondary Motion Accuracy Improved by Quaternion-Based Optimizer With Bony Landmark Constraints
J Biomech Eng (December,2010)
Roentgen Stereophotogrammetric Analysis Methods for Determining Ten Causes of Lengthening of a Soft-Tissue Anterior Cruciate Ligament Graft Construct
J Biomech Eng (August,2008)
Simultaneous In Vitro Measurement of Patellofemoral Kinematics and Forces
J Biomech Eng (June,2004)
Related Proceedings Papers
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
GD&T as a Language
Geometric Dimensioning and Tolerancing Handbook: Applications, Analysis & Measurement
GD&T as a Language
Geometric Dimensioning and Tolerancing: Applications, Analysis, Gauging and Measurement [per ASME Y14.5-2018]