The rheological behavior of mammalian tendon is analyzed in terms of its constituents structure and their properties. The elastic fibers are assumed to be straight and linearly elastic. They are of predominant role in the low ranges of strain. The collagen fibers are nonuniformly undulated. Upon stretch they gradually become straight, thus increasing the stiffness of the tissue. They are assumed to be linearly viscoelastic with negligible bending strength. It is shown that the nonuniformity of the collagen fiber structure can account for the observed nonlinear load-strain relations as well as for the nonlinear viscoelastic behavior of the tendon. An experimental procedure is developed through which the material functions and parameters can be determined.
Skip Nav Destination
Article navigation
November 1980
Research Papers
A Microstructure Model for the Rheology of Mammalian Tendon
Y. Lanir
Y. Lanir
Department of Biomedical Engineering, Technion—Israel Institute of Technology, Haifa, Israel
Search for other works by this author on:
Y. Lanir
Department of Biomedical Engineering, Technion—Israel Institute of Technology, Haifa, Israel
J Biomech Eng. Nov 1980, 102(4): 332-339 (8 pages)
Published Online: November 1, 1980
Article history
Received:
October 30, 1978
Revised:
May 11, 1979
Online:
June 15, 2009
Connected Content
Citation
Lanir, Y. (November 1, 1980). "A Microstructure Model for the Rheology of Mammalian Tendon." ASME. J Biomech Eng. November 1980; 102(4): 332–339. https://doi.org/10.1115/1.3138231
Download citation file:
Get Email Alerts
Effect of Internal Mechanical Environment of Porous Scaffolds on Mechano-driven Bone Ingrowth: A Numerical Study
J Biomech Eng (September 2023)
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
J Biomech Eng (September 2023)
Related Articles
Strain-Rate Sensitive Mechanical Properties of Tendon Fascicles From Mice With Genetically Engineered Alterations in Collagen and Decorin
J Biomech Eng (April,2004)
Time-Dependent Mechanical Behavior of Sheep Digital Tendons, Including the Effects of Preconditioning
J Biomech Eng (February,2002)
Erratum: “Comparison of Viscoelastic, Structural, and Material Properties of Double-Looped Anterior Cruciate Ligament Grafts Made From Bovine Digital Extensor and Human Hamstring Tendons” [ASME J. Biomech. Eng., 123 , No. 2, pp. 162–169]
J Biomech Eng (October,2001)
Simple Shear Testing of Parallel-Fibered Planar Soft Tissues
J Biomech Eng (April,2001)
Related Proceedings Papers
Related Chapters
Processing/Structure/Properties Relationships in Polymer Blends for the Development of Functional Polymer Foams
Advances in Multidisciplinary Engineering
Characterization of Tissue Viscoelasticity from Shear Wave Speed Dispersion
Biomedical Applications of Vibration and Acoustics in Imaging and Characterizations
Creating and Eliminating Workplace Hazards by Design
An Instructional Aid For Occupational Safety and Health in Mechanical Engineering Design