Thermal impact factors—namely, temperature-dependent R-value (TDRV), thermal bypass, and thermal bridging—are currently not addressed in the thermal design of commercial roofs. Therefore, the National Research Council of Canada has been generating data on these influencing factors for improving the thermal design of roofs. The mean operating temperature (MOT) of the roof assembly directly affects the thermal performance of the insulation. Through an in situ field study, test data were collected on the MOT of the roof assemblies and its relation to the insulation's TDRV. A comparison of two energy transfer theoretical models with the measured data indicated that the conventional approach to roof thermal design underestimates the energy expenditure of the roof assembly. The impact of thermal bypass due to air gaps formed at the insulation joints and fastener thermal bridging was also investigated through various experiments. The effect of gap width, height, and stagger was investigated for thermal bypass. For thermal bridging, experiments were conducted that examined the effect of fastener density, location, diameter, and penetration depth on the thermal performance of the roofing assembly. From the experimental data, psi factors and chi factors were developed to support the calculation of linear thermal bridging and point thermal bridging effects and to fill in the missing gaps in the energy codes for the thermal design of roofs. Because the thermal bridging from rooftop solar mounts is also a concern in the thermal design of roofing assemblies, experiments were conducted on several common solar mounts. The measured data indicated a decrease in the effective thermal resistance of the photovoltaic roofing assembly (PVRA), ranging from 3.3% to 50.0%. This paper summarizes these research findings and demonstrates the effect of these thermal impact factors on roof thermal design through two examples.

1.
Reilly
A.
and
Kinnane
O.
, “
The Impact of Thermal Mass on Building Energy Consumption
,”
Applied Energy
198
(April
2017
): 108–121,
2.
Kumaran
M. K.
,
Bomberg
M. T.
,
Marchand
R. G.
,
Ascough
M. R.
, and
Creazzo
J. A.
, “
A Method for Evaluating the Effect of Blowing Agent Condensation on Sprayed Polyurethane Foams
,”
Journal of Thermal Insulation
13
, no.
2
(
1989
): 123–137,
3.
Bogdan
M.
,
Hoerter
J.
, and
Moore
F. O.
 Jr.
, “
Meeting the Insulation Requirements of the Building Envelope with Polyurethane and Polyisocyanurate Foam
,”
Journal of Cellular Plastics
41
, no.
1
(
2005
): 41–56.
4.
Schumacher
C.
,
Ricketts
L.
,
Finch
G.
, and
Straube
J.
,
The Effect of Temperature on Insulation Performance: Considerations for Optimizing Wall and Roof Designs
(
Vancouver, BC
:
RDH Building Engineering
,
2014
).
5.
Graham
M.
, “
R-Value Concerns
,” Professional Roofing, May
2010
.
6.
Energy Standard for Buildings Except Low-Rise Residential Buildings
, ASHRAE 90.1-2013 (
Peachtree Corners, GA
:
American Society of Heating, Refrigerating, and Air-Conditioning Engineers
,
2013
).
7.
Canadian Commission on Building and Fire Codes
,
National Energy Code of Canada for Buildings
, NECB (
Ottawa, ON
:
National Research Council of Canada
,
2015
).
8.
Standard Practice for Calculating Thermal Transmission Properties under Steady-State Conditions
, ASTM C1045-07 (
West Conshohocken, PA
:
ASTM International
, approved November 1,
2007
),
9.
Molleti
S.
,
Carrigan
L.
, and
van Reenen
D.
, “
Mean OperatingTemperature (MOT) of Commercial Roof Assembly and Its Impact on the Energy Performance
,”
Buildings
11
, no.
5
(
2021
): 216,
10.
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
, ASTM C518-15 (
West Conshohocken, PA
:
ASTM International
, approved September 1,
2015
),
11.
Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
, ASTM C1289-22a (
West Conshohocken, PA
:
ASTM International
, approved October 1,
2022
),
12.
Molleti
S.
and
van Reenen
D.
, “
Development of Psi Factors for Thermal Bypass Due to Insulation Gaps in Low-Slope Roofing Assemblies
,”
Buildings
12
, no.
1
(
2022
): 68,
13.
Standard Test Method for Thermal Performance of Building Materials and Envelop Assemblies by Means of Hot Box Apparatus
, ASTM C1363-19 (
West Conshohocken, PA
:
ASTM International
, approved September 1,
2019
),
14.
Molleti
S.
,
van Reenen
D.
, and
Baskaran
A.
, “
Development of Chi-Factors towards Codification of the Thermal Bridging in Low Slope Roofing Assemblies
,”
Energy and Buildings
231
(
2021
): 110559,
15.
Building Components and Building Elements: Thermal Resistance and Thermal Transmittance: Calculation Method
, ISO 6946-07 (
Geneva, Switzerland
:
International Organization for Standardization
,
2007
).
16.
Molleti
S.
,
Chavez
M.
,
Ramful
C.
, and
Ko
S.
, “
Development of a New Dynamic Test Method to Determine the Wind Pressure Resistance of Photovoltaic Roof Assembly (PVRA)
,”
Journal of Testing and Evaluation
50
, no.
3
(May/June
2022
): 1313–1335,
18.
Molleti
S.
,
Carrigan
L.
, and
van Reenen
D.
, “
Impact of Solar Mounting Systems on the Thermal Design of Commercial Roofs
,”
Journal of Architectural Engineering
29
, no.
1
(March
2023
): 1–9.
This content is only available via PDF.
You do not currently have access to this chapter.
Close Modal

or Create an Account

Close Modal
Close Modal